DITEC LUC40H Manual
DITEC
Automatiske døre
LUC40H
Læs gratis den danske manual til DITEC LUC40H (46 sider) i kategorien Automatiske døre. Denne vejledning er vurderet som hjælpsom af 42 personer og har en gennemsnitlig bedømmelse på 3.8 stjerner ud af 21.5 anmeldelser. Har du et spørgsmål om DITEC LUC40H, eller vil du spørge andre brugere om produktet?
Side 1/46

Entrematic LCU40H
Control panel installation manual for
automations with one or two 24V motors
(Translation of the original instructions)
www.entrematic.com
IP2246EN • 2018-03-23
36 35 34 33 32 31
30 2 3 4 9 13
+-LP - +LK 30 5 20 016 018
JR1
J13J14
24V~
COM
A
U
X
2
A
U
X
1
UP
DOWN
TRF
ENTER
ESC
USB
BAT KIT
SCHEDA AD INNESTO
SCHEDA AD INNESTO
F
U
S
E
F1
RDX
6ZENRS
ZENPRS
Trasformatore
Alimentazione
Motore 2
24V
Motore 1
Passo-passo
Apertura parziale
Antenna
Chiusura
automatica esterna
Apertura
Chiusura
Stop
Lampada stato
automazione
Lampeggiante
Elettroserratura
AUX1 AUX2
1
30 30
1
-
+
Uscita 24 V
-
+
Uscita 24 V
Arresto di sicurezza
Sicurezza in chiusura
24V
LN
Power supply
Motor 2 Motor 1
Flashing light
Electric lock
Step-by-step
Partial opening
24V output
24V output
Safety stop
Closing safety device
Antenna
Automatic external closing
Opening
Closure
Stop
Automation status
lamp
Transformer

2
IP2246EN
Contents
Subject Page
1. General safety precautions 3
1.1 Safety functions 4
2. EC Declaration of Conformity 4
3. Technical specifications 4
3.1 Applications 4
4. Installation and electrical connections 5
4.1 Maintenance 7
4.2 Standard installation 7
4.3 Standard installation diagram 8
5. Programming 9
5.1 Switching the display ON and OFF 9
5.2 Navigation keys 9
5.3 Menu map 10
6. Quick start-up sequences 12
7. Application examples 14
8. Commands 16
8.1 Inserting the plug-in boards 17
8.2 SOFA1-SOFA2 or GOPAVRS self-controlled safety edge 17
9. Outputs and accessories 18
10. Selections 19
11. Adjustments 20
11.1 Main menu 20
11.2 Second level menu - AT (Automatic Configurations) 21
11.2.1 Selecting the type of automation AT → AS and specific default settings 22
11.3 Second level menu - BC (Basic Configurations) 23
11.3.1 Additional BC level parameters that can be configured (available with AT → AA enabled) 23
11.4 Second level menu - BA (Basic Adjustment) 24
11.4.1 Additional BA level parameters that can be configured (available with AT → AA enabled) 26
11.5 Second level menu - RO (Radio Operations) 28
11.5.1 Additional RO level parameters that can be configured (available with AT → AA enabled) 29
11.6 Second level menu - SF (Special Functions) 30
11.6.1 Additional SF level parameters that can be configured (available with AT → AA enabled) 31
11.7 Second level menu - CC (Cycle Counter) 32
11.7.1 Additional CC level parameters that can be configured (available with AT → AA enabled) 33
11.8 Second level menu - EM (Energy Management) 33
11.8.1 Additional EM level parameters that can be configured (available with AT → AA enabled) 34
11.9 Second level menu - AP (Advanced Parameters) 34
11.9.1 Additional AP level parameters that can be configured (available with AT → AA enabled) 36
12. Diagnostics 38
13. Signals visualised on the display 40
14. Troubleshooting 45
Key
i
This symbol indicates useful information for the correct functioning of the product.
Factory settings
This symbol indicates instructions or notes regarding safety, to which special atten-
tion must be paid.
Produkt Specifikationer
Mærke: | DITEC |
Kategori: | Automatiske døre |
Model: | LUC40H |
Har du brug for hjælp?
Hvis du har brug for hjælp til DITEC LUC40H stil et spørgsmål nedenfor, og andre brugere vil svare dig
Automatiske døre DITEC Manualer
24 August 2024
22 August 2024
21 August 2024
20 August 2024
18 August 2024
17 August 2024
16 August 2024
16 August 2024
15 August 2024
Automatiske døre Manualer
Nyeste Automatiske døre Manualer
16 September 2024
27 August 2024
24 August 2024
23 August 2024
22 August 2024
21 August 2024
18 August 2024
17 August 2024
15 August 2024
14 August 2024