Dormakaba Auditcon 52 Manual


Læs gratis den danske manual til Dormakaba Auditcon 52 (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 13 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 7 anmeldelser. Har du et spørgsmål om Dormakaba Auditcon 52, eller vil du spørge andre brugere om produktet?

Side 1/4
LOCK MODES
A maximum of two users can exist in a lock. A lock can operate in either Single Mode or
Dual Custody Mode.
Note:
For a UL listed installation, only one user can be activated.
Single Mode E
Single Mode defaults to having only a Manager User (User 1) in the lock. A second
user (User 2) can then be added by the Manager User (User 1). (See section on
Manager User Operations.)
In Single Mode only one valid user combination is required to open the lock - the Manager
User (User 1) combination or the User 2 combination.
Note:
Default lock status from the factory is Single Mode with an opening
combination of “502550” for the Manager User (User 1).
Dual Custody Mode E E
Dual Custody Mode defaults to two users in the lock - User 1 and User 2.
Two user combinations are required to open the lock - the User 1 combination and the
User 2 combination.
Note:
Manager User Operations are not available in Dual Custody Mode.
LOCK OPERATING CONVENTIONS
The power source for the Auditcon 2 Lock Series is PowerStar
TM Technology.
With this technology an internal generator is used to create all necessary power.
Important Note: The lock must be manually powered before each operation by
briskly turning the dial back and forth .
To clear a combination or keystroke, press the key.
If the bolt is not retracted within 4-6 seconds after a valid opening combination is
accepted, the lock will “relock”.
Please note the following operational differences based on the type of bolt you have
installed:
Dead Bolt (Manual Locking) Technology: There is a Home position for the dial on
the lock that is directly related to the manual retraction or extension of the bolt. In the
“HOME” position, the lip of the dial will cover the red “open lock” indicator. The dial
must be positioned here on a lock “Open’ operation before you can successfully open
the lock. The dial must be turned to the right (CW) to retract the bolt and unlock the
lock. The dial must be turned to the left (CCW) to extend the bolt and lock the lock. The
lock may not open if more than a 5 lb. force is applied to the end or side of the bolt.
Slide Bolt (Auto Locking) Technology: Once a combination has been entered and
accepted, the lock bolt movement works in conjunction with the bolt works of the
container. When the bolt works are disengaged to open the container, the lock bolt will
slide into the “unlocked” or retracted position. Once the bolt works are extended to the
locked position, the lock bolt automatically slides into the “locked” position. The lock will
not open if force is applied to the end or side of the bolt.
AUDITCON® 2 SERIES
MODELS 52 & T52
OPERATING INSTRUCTIONS
Document Number 3056.025 Rev. A2 - 05/05
LOCK RESPONSES
The lock is “powered” when simultaneous green
G
and red
R
flashes display with
a beep 8.
Each keystroke generates a green flash
G
with a beep 8.
The completion of a step within an operation is indicated by a green flash
G
with a
beep 8.
The successful completion of an operation is indicated by simultaneous
green
G
and red
R
flashes.
If a valid combination or combinations are entered to open the lock, the lock will
respond as follows to indicate that the lock is ready to open:
Dead Bolt - 1 slow green flash
G
Slide Bolt - Continuous green flashes
G
... for approx. 5 seconds
An error is indicated by three red flashes with beeps.
R
8
R
8
R
8
If the Battery Assist option is included on your lock and a 9 Volt Alkaline has been
installed for Battery Assist, the LEDs will continually flash throughout the duration of a
Time Delay or Open Window period. There is not a battery low indicator for Battery
Assist. If the feature is not functioning properly, check the battery.
TO UNLOCK
1. For a Dead Bolt, place the dial in the Home position.
2. For Single Mode
EE
EE
E (Factory combination is 502550.)
Enter Manager User (User 1) or User 2 combination.
G
88888
For Dual Custody Mode
EE
EE
E EE
EE
E
Enter User 1 or User 2 combination.
G
88
888
Enter the second combination.
G
88
888
Wrong Try Penalty: 5 wrong tries = 3 min. lockout
Each additional wrong try = 3 min. lockout
Red flashes with beeps
R
88
888 will occur during the lockout while lock is powered.
3. For a Dead Bolt, dial right (clockwise) until the lock bolt is retracted. For a Slide
Bolt, rotate the container handle to unlock.
CHANGE COMBINATION
Caution:
When selecting a combination, do not use a birthday or other predictable data that
could give a correlation between the user and the combination.
Before changing a combina-
tion, open the container door to allow testing with the new combination.
1. For User 1 (Manager User in Single Mode)
Press # and then 1.
G
88
88
8
For User 2 (Must be added by Manager User in Single Mode)
Press #, # 1 and then .
G
88
88
8
2. Enter current combination. (Factory combination is 502550”.)
G
88
888
3. Enter new six-digit combination.
G
88
888
4. Enter new combination again for verification.
G
R
5. Open the lock with the new combination before closing container.
6. Record new combination and store it in a secure place.


Produkt Specifikationer

Mærke: Dormakaba
Kategori: Ikke kategoriseret
Model: Auditcon 52

Har du brug for hjælp?

Hvis du har brug for hjælp til Dormakaba Auditcon 52 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Dormakaba Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer