STEAM WALLPAPER STRIPPER
OPERATING INSTRUCTIONS
MODEL SS100
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE
Thank you for purchasing an Earlex Steam Wallpaper Stripper. This is a highly versatile machine
for use all around the home. In order to obtain the best results please read the instructions
before
commencing any work.
Please also make a special note of the safety rules and
RETAIN FOR FUTURE REFERENCE
2
CAUTION !
Check the state of your plaster before starting work.
Steam can loosen weak, porous or poorly bonded plaster - which also loosens readily if cracked, holed or if the steam
plate is held in one position for too long after the paper is soaked.
Weak plaster can normally be detected by tapping a few areas of wall. A hollow sound indicates that you should
proceed only with extreme care - stopping immediately if you hear a cracking sound or plaster starts to break loose.
The steam stripper is safe for drywall/plaster board surfaces but whatever the material, it is always wise to check a
small area before starting work properly.
PREPARATION
To achieve fastest paper removal always gently score the areas to be stripped.
With heavily embossed, vinyl coated or painted papers this is essential. Either use a proprietory
perforator tool or alternatively score the paper with the edge of a wall scraper in a criss-cross
pattern with 150mm (6 inch) spacing.
As with all decorating work be sure to protect carpets and furniture with covers.
FITTING CORNER BUMPERS AND CASTORS
A pack of 4 plastic corner pieces and 4 castors is enclosed to protect the unit. To fit the corner pieces
simply push these over the aluminium edges at each corner and press home. To fit the castors turn the
boiler upside down and push the castors in hard until they stop. Once installed these remain in place
permanently.
OPERATION
STEAM IS HOT! The unit is designed for safe, fast removal of wallpaper but please be aware that steam is produced at
100
o
C - so be careful, wear protective clothing and protect your hands with heat resistant gloves or mitts.
FILLING:
Remove filler cap and fill unit to Max. level line or indicator with clean - preferably hot - water. Replace filler cap.
The capacity of 4.5 litres (8 pints) provides approx.70 mins. steaming time before the safety cut-out operates.
For a shorter steaming time use less water. Do not overfill the unit or hot water will be forced up the steam hose.
Screw hose onto threaded outlets of boiler and steam plate, hand tight is sufficient. Do not over tighten but do check
for hand tight fit from time to time during use.
Connect mains lead from unit to power socket and switch on. lt can take up to 15 mins (approx.) before steam is
produced - depending on fill water quantity and temperature.
Do not leave unattended and keep children & pets out of the room.
Just before full steam production a small amount of bubbling and water will occur at the steam plate.
Beware of hot water discharge prior to steam emission.
· Keep equipment away from children and pets.
· Ensure boiler is placed on a flat level surface, and
should the boiler become tilted in use - level again
immediately.
Failure to do so can result in severe overheating,
complete element failure and void of your guarantee.
· Block boiler unit securely if using on stairs.
· The boiler becomes hot in use. Move only by using
the carrying handle.
· Steam is produced at 100
o
C. Be careful, wear
protective clothing and protect your hands with heat
resistant gloves or mitts.
Never point hose or steam plate at anyone.
· Always keep steam plate tilted away from face and
body, beware of hot drips and regularly empty
collected condensation from plate - especially when
stripping ceilings and high areas.
Never remove filler cap or detach hose whilst unit is
operating.
Never block the safety valve.
Switch off and wait for 2 minutes before removing
filler cap to refill boiler.
Do not overfill.
Allow to cool completely before emptying boiler.
· Do not stand on boiler or hose.
· Do not drag or try to move boiler by pulling the
mains lead.
· Do not allow water or steam to enter light switches
or power points.
· Do not leave unattended.
Use only standard tap water. Never add detergents
or chemicals.
Extreme care must be taken if the unit is used in
bathrooms. Always be aware of danger of
electrocution from stored water in baths and sinks.
Never change tools when the unit is operating.
Always store upright.
Do not overfill the reservoir.
It is recommended that a RCD (residual current
device) rated at 30mA is fitted into the mains supply
socket for added protection against electric shock.
SAFETY RULES


Produkt Specifikationer

Mærke: Earlex
Kategori: Tapetafdamper
Model: SS100

Har du brug for hjælp?

Hvis du har brug for hjælp til Earlex SS100 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Tapetafdamper Earlex Manualer

Earlex

Earlex SS125 Manual

13 September 2025
Earlex

Earlex LMB230V Manual

13 September 2025
Earlex

Earlex LMB10V Manual

13 September 2025
Earlex

Earlex SS100 Manual

13 September 2025
Earlex

Earlex SS76 Manual

13 September 2025

Tapetafdamper Manualer

Nyeste Tapetafdamper Manualer

Wagner

Wagner 705 Manual

18 Januar 2024
Wagner

Wagner W15 Manual

7 November 2023
Cotech

Cotech PS-ZP-20 Manual

28 November 2022
Silverline

Silverline 128966 Manual

17 November 2022
Wagner

Wagner W14 Manual

5 November 2022
Wagner

Wagner 915 Manual

18 Oktober 2022