RM 100 Room climate Monitor ( Temp. r Operating Instructions CO2+ + H)
Product Overview
Thank you for selecting the RM 100 Room climate monitor. is smart, compact and easy- -use device In addition to measuring the CO It a to . 2
concentration, the RM 100 can also measure the ambient temperature and the relative humidity (CO2 Temp. r+ + H). This product is developed
to help people taking care of the Indoor Air Quality. The RM 100 can be widely used in office buildings, schools, exhibition halls, shopping malls,
meeting rooms, fitness centers, restaurants lic places where personal comfort healthy environment is important. and other pub and a
Features:
Three different LEDs show the current Indoor Air Quality
MUTE button for alarm on/off.
Built-in LCD backlight for easy reading in the dark
Warnings:
Please take off the AC power adapter and store it well when this CO2 monitor left is idle for
long.
This CO2 monitor is for home use, not suitable for certifying test results.
EMC/RFI
Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per meter, but the
performance of the instrument will not be permanently affected.
Note: Within an electromagnetic field of 3V/m, the reading will not meet the specification.
Warm-U Time: 2 MIN. p
Using the MUTE function:
Safety Instructions
Your safety is very important to us .To ensure using the product correctly and safely, we would like to draw your attention to read the warning and the entire user
manual before using the product. These are important safety information and should be observed at all times.
1. Please handle the devices lightly, not subject the product to impact or shock. do Otherwise, this may cause an accuracy drift.
2. Do not immerse the product in water. Water can cause electric shock, fire or malfunction which may result in . damage
3. Do not keep the product under hot and moisture environments. Keep the product away f m heat sources or near water. ro
4. Please use only the included power adaptor. Improper power adaptors or power sources can cause serious damage to the product, or result in injury or death
to the user.
Caring for the product
To ensure you gain the maximum benefit from using this product, please observe the follow guidelines.
1. Cleaning Disconnect the power before clean. Use a damp cloth, do not use a liquid cleaning agent, such as benzene, thinner or aerosols.
2. Repair Do not attempt to repair the product or modify the circuitry by yourself. Please contact with the local dealer or a qualified repairman if the product
needs servicing.
3. Air diffusion The ventilation slots on the housing are designed for CO 2 diffusion, so these ventilation slots should not be blocked.
1. Green LED Display (<800ppm)
2. Yellow LED Display (800-1200ppm)
3. Red LED Display (>1200ppm & buzzer alarm)
4 Mute Button .
5. Power Inlet
6. Housing Stand
7. Screw Position
8. Ventilation Slots
1. 2 min. warm-up time when powering up for the first time.
2. The LCD shows 4 bars with 1sec blank cycle during warm- up
3. up The MUTE button is disabled during warm-
4. The device shows the CO2 reading after warm- up
Press MUTE button to select buzzer on/off. If the M function is off, while “ UTE” CO2 concentration exceed the alarm level (>1200 ppm), there will be a buzzer.
Note: The device setting of the alarm is buzzer when power on first time, user can set the alarm on/off under MUTE function. on
SPECIFICATIONS
Method -Dual Beam NDIR (Non-Dispersive-Infrared)
Display - LCD Independent CO2, rH temperature readings and
Sample Method - Diffusion or flow through (50 ml/min).~200
CO2, Temperature Specification: rH &
CO2 Specification:
Measurement Range
0-3,000 ppm display
Display Resolution
1 at 0~1,000ppm; at 1, 1 ,000ppm; 10ppm at 2, 1~ 000ppm ppm 5ppm 00 ~2 00 3,
Accuracy
Under 25°C: ±80 ppm or ±5% of reading ( 2000ppm) ±7% reading (>2000ppm);
Repeatability
±20 ppm @ 400ppm
Temperature Dependence
Typ. 2% of reading per °C or ±2 ppm per °C, whichever is greater, referenced to 25°C ±0.
Response Time
About 2min for 63% of step change
Warm-Up Time
2 min. at 22°C
Zone LED Display
Green: <800ppm; Yellow: 800~1200ppm;Red: >1200 ppm
Temperature Specification:
Temperature Range
0°C to 50°C (32°F to 122°F) display
Display Resolution
0.1°C (0.1°F)
Display Options
°C/°F
Accuracy
±1°C( ±2°F When the fan blows to the device directly, the accuracy of temperature is + / -1.5 degC )
Response Time
20-30 minutes (case must equalize with environment)
r H Specification:
Measurement Range
20%-90%rH
Display Resolution
1%rH
Accuracy:
±5%rH@23°C
Response time:
< min for 63% of step change 5
Operating Conditions:
Operating Temperature
0°C to 50°C (32°F to 122°F)
Humidity Range
0 ~ 95% rH non-condensing
Storage Conditions:
Storage Temperature
-20°C to 60°C( -4°F to 140°F)
Power Supply:
Power Supply
USB or 5 VDC from external AC/DC adapter which is included in package (Use specified AC adapter only)
DC Output voltage
5 VDC
AC Input voltage & Frequency
100 ~ 240 VAC, 0.2A 50 / 60 Hz
Dimensions
Error Codes & Troubleshooting Guide
Error Code
Suggested Actions
「 」
This error will clear when the temperature returns the range between to
0°C to 50°C (32°F to 122°F ).
「 」
Please reconnect AC adapter the RM 100 to .
If the “Er ” still appearr5, Err6 s please contact the Service Department for ,
further assistance.
WTW GmbH Geschäftsbereich ebro Electronic
Peringerstr. 10 85055 Ingolstadt - Germany.
Tel. +49 841 95478-0
ebro@xyleminc.com
http://www.ebro.com