MANUAL
CARBON MONOXIDE ALARM
CBFC28
If CO concentraon overruns 20PPM, the funcon of
temperature display will be disable.
3.3 CO alarm warning
emit a loud alarm paern. The alarm signal paern is 4 beeps
followed by 2 seconds of silence. The ALARM indicator (red) will
flash the same paern. This cycle repeats as long as a dangerous
CO condion exists.
Alarm sensivity seng:
Conforms to EN 50291-1:2018
30PPM : Without alarm before 120 minutes
50PPM : Alarm between 60 to 90 minutes
100PPM : Alarm between 10 to 40 minutes
300PPM : Alarm within 3 minutes
NOTE: Refer to “3. What to do if the alarm sounds” when you
hear the sounds of the CO alarm warning.
3.4 CO alarm warning silence
During the device under CO alarm mode, pressing
theTEST/SILENCE buon, it will be paused alarm sound of the
device about 10 minutes. The ALARM indictor (red) will keep
flash as CO alarm mode, it indicates the device is running into
the CO alarm silence mode.
NOTE: The audible alarm signal will reacvate about 10
minutes from the me the TEST/SILENCE buon is operated
where the concentraon of CO surrounding the alarm remains at
50 PPM or greater.
NOTE: The audible alarm signal cannot to silence if the alarm
at concentraon above 200 PPM.
NOTE: The alarm silencing acvaon to once throughout a CO
alarm period.
WARNING! Before enable feature of CO alarm warning silence,
you should be confirmed that the alarm is due to dangerous
levels of carbon monoxide and the dwelling should be venlated.
3.5 Low baery voltage warning
If the device chirps once every 40 seconds, with FAULT indicator
(yellow) will be flash. It indicates the baery is low. The LCD
displays always displays " ".
NOTE: When the low baery voltage warning is occur, the device
has capable of producing a CO alarm signal for at least 4 min or
30 days of low baery voltage warning signal operaon.
NOTE: The device will not protect against the risk of carbon
monoxide poisoning when the baery has drained.
3.6 Low baery voltage warning silence
When the device is under the low baery warning, pressing the
TEST/SILENCE buon, it will come into a low baery voltage
warning silence status for about 9 hours, meanwhile it will
appear " " on LCD, and FAULT indicator (yellow) sll keep
flashing.
NOTE: The silence feature of low baery voltage warning is
temporary acon to cancel warning sound effect, you need
replace the baery as soon as possible.
3.7 Fault warning
If the device chirps twice every 40 seconds with FAULT indicator
(yellow) will be flash. It indicates the CO alarm is in malfuncon
condion. The LCD displays " Err ", that means your CO alarm
have no detecng funcon and no respond CO.
NOTE: Maybe the sensor is missing, replace the device
immediately. Please contact us to more service.
3.8 Fault warning silence
When the device is in a fault state, press the TEST/SILENCE
buon, it will enter the fault warning mute state for about 9
hours, while displaying " " on the LCD, and the FAULT indicator
(yellow) remains flashing.
NOTE: The silence feature of fault warning is a temporary acon
to cancel warning sound effect, you need replace the device as
soon as possible.
3.9 End-of-life warning
If the device chirps 3 mes every 40 seconds with FAULT
indicator (yellow) flash and the LCD displays ‘End’. It indicates
end of life of CO alarm. You need to immediately replace the CO
alarm.
3.10 End-of-life warning silence
When the device is in the End-of-life state, press the
TEST/SILENCE buon, it will enter the End-of-life warning mute
state for about 9 hours, while displaying " " on the LCD, and the
FAULT indicator (yellow) remains flashing.
NOTE: The silence feature of fault warning is a temporary acon
to cancel warning sound effect, you need replace the device as
soon as possible.
Entree
Manufacturer
Siterwell Electronics CO., Limited
No.666 Qingfeng Road, Jiangbei District,
Ningbo, Zhejiang Province, China 315034
Importer:
ELRO Europe | www.elro.eu
Postbus 9607 - Box E800
1006 GC Amsterdam The Netherlands
Minimum
Extra
Reliable electrochemical sensor
Incl. 2x 1,5V baeries
Silence mode
Low-baery indicator
End-of-life indicator
The alarm should be installed by a competent person.
This apparatus is designed to protect individuals from the acute
effects of carbon monoxide exposure. It will not fully safeguard
individuals with specific medical condions. If in doubt consult a
medical praconer.
Document nr.: CBFC28_MN_EN | Revision nr. : 2 | Revision date: 22-09-2021
Type B apparatus
EN50291-1:2018
-1- -2- -3-
Thank you for purchasing the CBFC28 carbon
monoxide (CO) alarm.
This unit uses advanced electrochemical sensor, and with LCD
digital display for CO concentraon. Please take a few minutes to
thoroughly read the user manual before operang or servicing
and familiarize yourself andyour family with its operaon. And
save for future reference.
CAUTION:
This CO alarm is designed for indoor use only. Do not expose to
rain or moisture. Do not knock or drop the detector. Do not open
or tamper with the alarm as this could cause malfuncon. The
alarm will not protect against the risk of carbon monoxide
poisoning when the baery has drained. Installaon of the alarm
should not be used as a substute for proper installaon, use
and maintenance of fuel burning appliances including
appropriate venlaon and exhaust systems.
WARNING! - Do NOT try to repair the device, it has the risk of
electric shock or malfuncon if the device is tampered with.
Table of Contents
1. Installaon instrucons
2. Product overview
3. Understanding your CO alarm
4. What to do if the alarm sounds
5. Baery installaon/replacement
6. General maintenance
7. Carbon monoxide overview
8. Specificaon
1. INSTALLATION INSTRUCTIONS
1.1 Installaon locaon
When choosing your installaon locaons, make sure you can
hear the alarm from all sleeping areas. If you install only one CO
alarm in your home, install the alarm near bedrooms. Not in the
basement or furnace room. The recommended posion for the
unit should be at least 1.8 meters (about 6 feet) above the floor
level.
CAUTION: This alarm should be installed by a competent person.
1.2 Mounng step
1. Drilling two ф5.0mm holes in the wall, the distance between
two holes center is 52mm, then inserng two plasc stopper
provided into the holes.
2. Insert the two screws provided unl the screw heads are
approximately 5mm from wall.
3. Test the unit by using the TEST/SILENCE buon. Ensure the
unit sound is alarm paern.
4. Hook the unit over the screws onto keyholes in back of unit.
1.3 Recommended installaon locaons:
The following suggesons are intended to help you with the
placement and installaon of your CO alarm.
Place out of the reach of children. Under no circumstance
should children be allowed to handle the CO alarm.
Install in a bedroom or hallway located close to the sleeping
area. Take special care to verify the alarm can be heard in
sleeping areas.
It is recommended that a CO alarm be installed on each level
of a mullevel home.
Locate 1~3 meter (3.3~10feet) away from all fuel burning
appliances.
Placing at eye level allows for opmum monitoring of the red
and green indicator lights.
Insure that all vents of the unit are unobstructed.
Do not install in dead air spaces such as peaks of vaulted
ceilings, or gabled roofs.
Do not install in turbulent air from ceiling fans.
Do not place near fresh air vents or close to doors and
windows that open to the outside.
Keep the CO alarm away from excessively dusty, dirty, or
greasy areas such as kitchens, garages and furnace rooms.
Dust, grease and household chemicals can affect the sensor.
Keep out of damp and humid areas such as the bath room.
Avoid spraying aerosols near the CO alarm.
Do not install in areas where the temperature is below -10°C
or hoer than 45°C.
Do not place behind curtains or furniture. CO must be able to
reach the sensor for the unit to accurately detect CO.
2. PRODUCT OVERVIEW
2.1 FAULT indicator
The FAULT indicator (yellow LED) is used to indicate fault or
warning status of the CO alarm.
2.2 POWER indicator
The POWER indicator (green LED) is used to indicate power
status of the CO alarm. The POWER indicator will flash every 40
seconds.
2.3 ALARM indicator
The ALARM indicator (red LED) is used to indicate alarm status of
the CO alarm.
2.4 TEST/SILENCE buon
The TEST/SILECNE buon is used to test the unit. Press and hold
to enable TEST funcon.
2.5 Alarm sounder
The alarm sounder is used to send out CO alarm warning and
fault warning informaon.
2.6 LCD screen
Indicates CO concentraon and alarm status.
3. UNDERSTANDING YOUR CO ALARM
3.1 Start up
When first power on, the POWER indicator (green) flash every
second, This is preheated state, 60 seconds later the POWER
indicator (green) flashing every 40 seconds indicates the unit is
funconing properly. The LCD displays all segments 4s and count
down. When the countdown is "0", the product goes into normal
operaon.
3.2 Normal operaon
The POWER indicator (green) flashing once every 40 seconds.
The LCD alternately displays current CO concentraon and
temperature every 40s.
CO concentraon display range 0~999PPM.
If the CO concentraon is under 20PPM, the LCD will
display "0PPM".
If the CO concentraon overruns 999PPM, the LCD will
display "999PPM".
Temperature display range: -9~50°C.
CARBON MONOXIDE ALARM
2.5
2.4
2.6
2.2 2.32.1


Produkt Specifikationer

Mærke: Elro
Kategori: Røgdetektor
Model: CBFC28

Har du brug for hjælp?

Hvis du har brug for hjælp til Elro CBFC28 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Røgdetektor Elro Manualer

Elro

Elro FS151021M Manual

8 Oktober 2024
Elro

Elro 2001-023 Manual

3 Oktober 2024
Elro

Elro RM150RF Manual

19 September 2024
Elro

Elro FS1105P Manual

17 September 2024
Elro

Elro RM230 Manual

13 September 2024
Elro

Elro RM127K Manual

30 August 2024

Røgdetektor Manualer

Nyeste Røgdetektor Manualer

Hochiki

Hochiki HCA-4 Manual

26 Februar 2025
Hochiki

Hochiki SOC-24V Manual

25 Februar 2025
Hochiki

Hochiki ALN-V Manual

25 Februar 2025
Hochiki

Hochiki ACC-V Manual

25 Februar 2025
First Alert

First Alert SMICO110 Manual

23 Februar 2025
Drayton

Drayton CCT599002 Manual

20 Februar 2025
LogiLink

LogiLink SC0016 Manual

29 Januar 2025
FirstAlert

FirstAlert SA700CE Manual

12 Januar 2025