Elro CBFC28 Manual


Læs gratis den danske manual til Elro CBFC28 (4 sider) i kategorien Røgdetektor. Denne vejledning er vurderet som hjælpsom af 27 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 14 anmeldelser. Har du et spørgsmål om Elro CBFC28, eller vil du spørge andre brugere om produktet?

Side 1/4
-4- -5-
EN
MANUAL
CARBON MONOXIDE ALARM
CBFC28
If CO concentraon overruns 20PPM, the funcon of
temperature display will be disable.
3.3 CO alarm warning
emit a loud alarm paern. The alarm signal paern is 4 beeps
followed by 2 seconds of silence. The ALARM indicator (red) will
flash the same paern. This cycle repeats as long as a dangerous
CO condion exists.
Alarm sensivity seng:
Conforms to EN 50291-1:2018
30PPM : Without alarm before 120 minutes
50PPM : Alarm between 60 to 90 minutes
100PPM : Alarm between 10 to 40 minutes
300PPM : Alarm within 3 minutes
NOTE: Refer to “3. What to do if the alarm sounds” when you
hear the sounds of the CO alarm warning.
3.4 CO alarm warning silence
During the device under CO alarm mode, pressing
theTEST/SILENCE buon, it will be paused alarm sound of the
device about 10 minutes. The ALARM indictor (red) will keep
flash as CO alarm mode, it indicates the device is running into
the CO alarm silence mode.
NOTE: The audible alarm signal will reacvate about 10
minutes from the me the TEST/SILENCE buon is operated
where the concentraon of CO surrounding the alarm remains at
50 PPM or greater.
NOTE: The audible alarm signal cannot to silence if the alarm
at concentraon above 200 PPM.
NOTE: The alarm silencing acvaon to once throughout a CO
alarm period.
WARNING! Before enable feature of CO alarm warning silence,
you should be confirmed that the alarm is due to dangerous
levels of carbon monoxide and the dwelling should be venlated.
3.5 Low baery voltage warning
If the device chirps once every 40 seconds, with FAULT indicator
(yellow) will be flash. It indicates the baery is low. The LCD
displays always displays " ".
NOTE: When the low baery voltage warning is occur, the device
has capable of producing a CO alarm signal for at least 4 min or
30 days of low baery voltage warning signal operaon.
NOTE: The device will not protect against the risk of carbon
monoxide poisoning when the baery has drained.
3.6 Low baery voltage warning silence
When the device is under the low baery warning, pressing the
TEST/SILENCE buon, it will come into a low baery voltage
warning silence status for about 9 hours, meanwhile it will
appear " " on LCD, and FAULT indicator (yellow) sll keep
flashing.
NOTE: The silence feature of low baery voltage warning is
temporary acon to cancel warning sound effect, you need
replace the baery as soon as possible.
3.7 Fault warning
If the device chirps twice every 40 seconds with FAULT indicator
(yellow) will be flash. It indicates the CO alarm is in malfuncon
condion. The LCD displays " Err ", that means your CO alarm
have no detecng funcon and no respond CO.
NOTE: Maybe the sensor is missing, replace the device
immediately. Please contact us to more service.
3.8 Fault warning silence
When the device is in a fault state, press the TEST/SILENCE
buon, it will enter the fault warning mute state for about 9
hours, while displaying " " on the LCD, and the FAULT indicator
(yellow) remains flashing.
NOTE: The silence feature of fault warning is a temporary acon
to cancel warning sound effect, you need replace the device as
soon as possible.
3.9 End-of-life warning
If the device chirps 3 mes every 40 seconds with FAULT
indicator (yellow) flash and the LCD displays ‘End’. It indicates
end of life of CO alarm. You need to immediately replace the CO
alarm.
3.10 End-of-life warning silence
When the device is in the End-of-life state, press the
TEST/SILENCE buon, it will enter the End-of-life warning mute
state for about 9 hours, while displaying " " on the LCD, and the
FAULT indicator (yellow) remains flashing.
NOTE: The silence feature of fault warning is a temporary acon
to cancel warning sound effect, you need replace the device as
soon as possible.
Entree
Manufacturer
Siterwell Electronics CO., Limited
No.666 Qingfeng Road, Jiangbei District,
Ningbo, Zhejiang Province, China 315034
Importer:
ELRO Europe | www.elro.eu
Postbus 9607 - Box E800
1006 GC Amsterdam The Netherlands
Minimum
Extra
Reliable electrochemical sensor
Incl. 2x 1,5V baeries
Silence mode
Low-baery indicator
End-of-life indicator
The alarm should be installed by a competent person.
This apparatus is designed to protect individuals from the acute
effects of carbon monoxide exposure. It will not fully safeguard
individuals with specific medical condions. If in doubt consult a
medical praconer.
Document nr.: CBFC28_MN_EN | Revision nr. : 2 | Revision date: 22-09-2021
Type B apparatus
EN50291-1:2018


Produkt Specifikationer

Mærke: Elro
Kategori: Røgdetektor
Model: CBFC28

Har du brug for hjælp?

Hvis du har brug for hjælp til Elro CBFC28 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Røgdetektor Elro Manualer

Elro

Elro FS151021M Manual

8 Oktober 2024
Elro

Elro 2001-023 Manual

3 Oktober 2024
Elro

Elro RM150RF Manual

19 September 2024
Elro

Elro FS1105P Manual

17 September 2024
Elro

Elro RM230 Manual

13 September 2024
Elro

Elro RM127K Manual

30 August 2024

Røgdetektor Manualer

Nyeste Røgdetektor Manualer

Hochiki

Hochiki HCA-4 Manual

26 Februar 2025
Hochiki

Hochiki SOC-24V Manual

25 Februar 2025
Hochiki

Hochiki ALN-V Manual

25 Februar 2025
Hochiki

Hochiki ACC-V Manual

25 Februar 2025
First Alert

First Alert SMICO110 Manual

23 Februar 2025
Drayton

Drayton CCT599002 Manual

20 Februar 2025
LogiLink

LogiLink SC0016 Manual

29 Januar 2025
FirstAlert

FirstAlert SA700CE Manual

12 Januar 2025