PRODUCT DATASHEET
Features
PRODUCT DATASHEET
FM200 Handheld Formaldehyde
(CH
2
O or HCHO) Meter
Measures Formaldehyde concentration, Air Temperature, and
Humidity. Adjustable audible alarm feature is excellent for
checking indoor air quality in buildings.
Features
Air Temperature, and Relative Humidity readings on
large LCD with backlight feature
Audible alarm default at 0.08ppm (adjustable)
Designed with Electrochemical CH
2
O sensor
Sensor LED indication where green indicates
sensor is connected properly and power is on,
red LED shows the fan is in working condition
(active = flashing red; inactive = solid red)
Built-in bumper that allows the fan inside the sensor to
draw in gas quickly
CH
2
O Calibration function in fresh air
Min/Max and Data Hold
Auto power off with disable
Low battery indicator
Complete with soft tube (approx. 1ft/300mm),
sensor with 2.1ft (657mm) cable, 6 AAA batteries
and carrying case
Ordering
FM200 Handheld Formaldehyde Meter ...............
www.extech.com
Specifications subject to change without notice. Copyright © 2014 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form.
Rev. 12/17/14
Specifications
Range Resolution Basic Accuracy
Formaldehyde (CH
2
O or HCHO) 0.00 to 5.00ppm 0.01ppm ±5%
Air Temperature 32 to 122°F (0 to 50°C) 0.1°F/°C ±2°F/1°C
Relative Humidity 10% to 90%RH 0.1%RH ±5%RH
Dimensions 6.3 x 2.4 x 1.6” (160 x 60 x 40mm)
Weight 6.4oz (181.4g)
Applications:
Formaldehyde is used in the manufacture of many industrial and consumer goods.
Emissions from some of these items can rise when moisture and heat increase.
These emissions are a contributing factor to Sick Building Syndrome, which may
lead to itchy eyes and throat, as well as headaches and dizziness.
- Glue/Paint manufacturers
- Insulation/Plywood/Fiberboard
- Timber Paneling/Particleboard
- Cosmetics
- Shampoos
- Soap Bars/Body Wash
UPC Code: 793950232002


Produkt Specifikationer

Mærke: Extech
Kategori: Måling
Model: FM200

Har du brug for hjælp?

Hvis du har brug for hjælp til Extech FM200 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måling Extech Manualer

Extech

Extech EA25 Manual

28 November 2025
Extech

Extech MA150 Manual

28 November 2025
Extech

Extech EA20 Manual

28 November 2025
Extech

Extech CA250 Manual

28 November 2025
Extech

Extech HD755 Manual

28 November 2025
Extech

Extech DV24 Manual

28 November 2025
Extech

Extech FM200 Manual

28 November 2025
Extech

Extech 480823 Manual

27 November 2025
Extech

Extech EC700 Manual

27 November 2025
Extech

Extech TB400 Manual

27 November 2025

Måling Manualer

Nyeste Måling Manualer

Terraillon

Terraillon COACH Manual

27 November 2025
FLIR

FLIR T530 Manual

27 November 2025
FLIR

FLIR TG268 Manual

27 November 2025
Testo

Testo 558s Manual

26 November 2025
Eastron

Eastron SEM1 Manual

25 November 2025
Vevor

Vevor SC256M Manual

25 November 2025
Vevor

Vevor SD304 Manual

25 November 2025
Vevor

Vevor SD314 Manual

25 November 2025