User's Guide
Autoranging Multimeter
Model MN47
MN47-EU-EN-V3.0–12/11 2
Introduction
Congratulations on your purchase of the MN47 MultiMeter. The MN47 offers AC/DC Voltage, AC/DC
Current, Resistance, Diode, and Continuity and Temperature. Proper use and care of this meter will
provide many years of reliable service.
Safety
This symbol adjacent to another symbol, terminal or operating device indicates
that the operator must refer to an explanation in the Operating Instructions to
avoid personal injury or damage to the meter.
This WARNING symbol indicates a potentially hazardous situation, which if not
avoided, could result in death or serious injury.
This CAUTION symbol indicates a potentially hazardous situation, which if not
avoided, may result damage to the product.
This symbol advises the user that the terminal(s) so marked must not be
connected to a circuit point at which the voltage with respect to earth ground
exceeds 600V.
This symbol adjacent to one or more terminals identifies them as being associated
with ranges that may, in normal use, be subjected to particularly hazardous
voltages. For maximum safety, the meter and its test leads should not be handled
when these terminals are energized.
SAFETY INSTRUCTIONS
This meter has been designed for safe use, but must be operated with caution. The rules listed
below must be carefully followed for safe operation.
1. NEVER apply voltage or current to the meter that exceeds the specified maximum:
Input Protection Limits
Function Maximum Input
V DC or V AC 600V AC and DC
mA AC/DC 400mA DC/AC
A AC/DC 10A DC/AC (for 30 seconds max. every 15 minutes
Frequency, Resistance, Capacitance,
Duty Cycle, Diode, Continuity,
Temperature
250V DC/AC
2. USE EXTREME CAUTION when working with high voltages.
3. DO NOT measure voltage if the voltage on the "COM" input jack exceeds 600V above earth ground.
4. NEVER connect the meter leads across a voltage source while t
he function switch is in the current, resistance, or
diode mode. Doing so can damage the meter.
5. ALWAYS discharge filter capacitors in power supplies and
disconnect the power when making resistance or diode
tests.
6. ALWAYS turn off power and disconnect test leads before opening the covers to replace the fuse or battery.
7. NEVER operate the meter unless the back cover and the battery and fuse covers are in place and fastened securely.
8. DO NOT use the meter if the meter or test leads look damaged, or if you suspect the meter is not operating properly.
9. If the equipment is used in a manner not specified by t
he manufacturer, the protection provided by the equipment may
be impaired.
WARNING
CAUTION
MAX
600V


Produkt Specifikationer

Mærke: Extech
Kategori: Multimeter
Model: MN47

Har du brug for hjælp?

Hvis du har brug for hjælp til Extech MN47 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Multimeter Extech Manualer

Extech

Extech 380942 Manual

22 December 2024
Extech

Extech MA440 Manual

28 August 2024
Extech

Extech EX355 Manual

27 August 2024
Extech

Extech EX623 Manual

27 August 2024
Extech

Extech MA443 Manual

27 August 2024
Extech

Extech MG302 Manual

23 August 2024
Extech

Extech Ex 830 Manual

17 August 2024
Extech

Extech Ex 810 Manual

14 August 2024
Extech

Extech EX 710 Manual

13 August 2024
Extech

Extech MA1500 Manual

12 August 2024

Multimeter Manualer

Nyeste Multimeter Manualer

Draper

Draper 52320 Manual

8 Juni 2025
VOREL

VOREL 81780 Manual

7 Juni 2025
Brymen

Brymen BM878 Manual

7 Juni 2025
Brymen

Brymen BM789 Manual

6 Juni 2025
Draper

Draper 16232 Manual

6 Juni 2025
Draper

Draper 41822 Manual

6 Juni 2025
Draper

Draper 41820 Manual

6 Juni 2025
Brymen

Brymen BM805s Manual

6 Juni 2025
Brymen

Brymen BM785 Manual

6 Juni 2025
Brymen

Brymen BM239R Manual

3 Juni 2025