Extech RF30 Manual


Læs gratis den danske manual til Extech RF30 (1 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Extech RF30, eller vil du spørge andre brugere om produktet?

Side 1/1
RF30-en-US_V1.2 3/15
User's Guide
0 to 90% Brix Refractometer
Model RF30
Introduction
Congratulations on your purchase of the Extech RF30 Brix Refractometer.
optical surface. Careful use of these instruments will provide years of
reliable service.
Specifications
Range 0 to 90% Brix in three scales:
1: (0 to 42%), 2: (42 to 71%),
3: (71 to 90%)
Resolution 0.2%
Dimensions 7.5 x 1.6 x 1.2" (190 x 40 x 30mm);
Weight 5.5 oz. (155g)
Description
1. Cover plate
2. Light window
3. Prism
4. Sharpness ring
5. Eyepiece and Focus
6. Light window
7. Scale select knob
Scale:
Operation
This instrument measures the refractive index of a sample. The measurement
is displayed in % Brix.
1. The 20ºC zero calibration is factory set. No further adjustment is
necessary.
2. Select the scale (1, 2 or 3) by rotating the scale select knob.
3. To take a sample reading, open the cover plate, place a few drops of the
sample (a vial of distilled water is
included) on the measurement
prism. Close the prism cover plate
so that the liquid spreads across
the entire surface of the prism
without air bubbles or dry spots.
Allow the sample to remain on the
prism for approximately 30
seconds.
4. While holding the instrument under
a light source, look through the
eyepiece. Rotate the eyepiece to adjust the focus
5. The sucrose concentration is determined by the intersection of the
boundary of the light and dark fields (known as the shadowline) on the
printed scale. Adjustment of the sharpness ring can improve the
shadowline definition.
6. It may be necessary to adjust the position of the light source to maximize
the contrast of the shadowline. The light window may also be opened or
closed to improve contrast.
7. Change the range if the line is offscale.
8. Once a reading has been taken, wipe dry with a clean cloth (do not wash
or rinse) and place the instrument in the supplied plastic case. Store the
instrument in a safe, dry environment.
Temperature Compensation
The RF30 Refractometer has been designed for use with a 20°C standard
temperature. If the temperature of the measurement deviates from 20°C, the
reading must be manually compensated in accordance with the Temperature
Compensation Table.
Example: Reading = 20%, Temperature = 28°C
20% + 0.62% (add from table) =20.62%.
Copyright ©2013 2015 FLIRSystems,Inc.
Allrightsreservedincludingtherightof orreproductioninwhole in inpart any
form
www.extech.com
Temperature Compensation Table (Referenced To 20
O
C)
%
0 5 10 15 20 25 30 35 40
o
C Subtract from the measured value
10 0.52 0.58 0.59 0.61 0.64 0.67 0.69 0.71 0.72
11 0.48 0.51 0.54 0.55 0.58 0.61 0.63 0.65 0.65
12 0.44 0.47 0.49 0.50 0.52 0.55 0.57 0.58 0.58
13 0.39 0.42 0.44 0.44 0.45 0.49 0.50 0.51 0.51
14 0.35 0.37 0.38 0.39 0.40 0.42 0.43 0.44 0.44
15 0.29 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.37
16 0.24 0.25 0.26 0.27 0.28 0.28 0.29 0.30 0.30
17 0.18 0.19 0.20 ‘0.20 0.21 0.21 0.22 0.22 0.23
18 0.12 0.13 0.13 0.14 0.14 0.14 0.15 0.15 0.15
19 0.06 0.06 0.07 0.07 0.07 0.07 0.07 0.08 0.08
Add to the measured value
21 0.06 0.07 0.07 0.07 0.07 0.07 0.08 0.08 0.08
22 0.13 0.14 0.14 0.14 0.14 0.15 0.15 0.16 0.16
23 0.20 0.21 0.21 0.22 0.22 0.23 0.23 0.23 0.23
24 0.27 0.28 0.29 0.29 0.30 0.30 0.31 0.31 0.31
25 0.34 0.35 0.36 0.37 0.38 0.38 0.39 0.39 0.40
26 0.42 0.43 0.44 0.44 0.46 0.46 0.47 0.47 0.48
27 0.50 0.51 0.52 0.53 0.54 0.55 0.55 0.56 0.56
28 0.58 0.59 0.60 0.61 0.62 0.63 0.64 0.64 0.65
29 0.66 0.67 0.68 0.69 0.70 0.71 0.72 0.73 0.73
30 0.74 0.75 0.77 0.78 0.79 '0.80 '0.81 0.81 0.81
%
45 50 55 60 65 70 75 80 85
o
C Subtract from the measured value
10 0.74 0.74 0.74 0.75 0.76 0.77 ---- ---- ----
11 0.67 0.67 0.67 0.68 0.68 0.69 ---- ---- ----
12 0.60 0.60 0.60 0.60 0.61 0.61 ---- ---- ----
13 0.53 0.53 0.53 0.53 0.53 0.53 ---- ---- ----
14 0.45 0.45 0.45 0.45 0.45 0.46 ---- ---- ----
15 0.38 0.38 0.38 0.38 0.38 0.38 0.38 0.37 0.07
16 0.30 0.31 0.31 0.31 0.31 0.31 0.30 0.30 0.30
17 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.22
18 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15
19 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.07
Add to the measured value
21 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.07
22 0.16 0.16 0.16 0.16 0.16 0.15 0.15 0.15 0.15
23 0.24 0.24 0.24 0.24 0.23 0.22 0.23 0.23 0.22
24 0.31 0.31 0.32 0.32 0.31 0.31 0.31 0.30 0.30
25 0.40 0.40 0.40 0.40 0.39 0.39 0.39 0.38 0.37
26 0.48 0.48 0.48 0.48 0.47 0.47 0.46 0.46 0.45
27 0.56 0.56 0.56 0.56 0.55 0.55 0.54 0.53 0.52
28 0.65 0.64 0.64 0.64 0.64 0.63 0.62 0.61 0.60
29 0.73 0.73 0.73 0.72 0.72 0.71 0.70 0.69 0.68
30 0.82 0.81 0.81 0.81 0.80 0.79 0.78 0.77 0.75
Warranty
FLIRSystems,Inc.warrantsthisExtechInstrumentsbranddevice to be free of defects inparts
and dateworkmanshipfor from oneyear of (a monthshipment six limitedwarrantyappliesto
sensorsandcables). becomeIfitshould necessaryto thereturn instrumentforserviceduringor
beyond contactthewarrantyperiod, theCustomerServiceDepartmentforauthorization.Visit
thewebsitewww.extech.comforcontactinformation. A ReturnAuthorization(RA) mustnumber
be any freight,issuedbefore productis isreturned.Thesender responsibleforshippingcharges,
insuranceandproperpackagingto topreventdamage does notintransit.Thiswarranty apply
defects action asresultingfrom oftheusersuch misuse,improperwiring, ofoperationoutside
specification,impropermaintenance or or repair, unauthorizedmodification.FLIRSystems,Inc.
specificallydisclaimsany forimpliedwarrantiesor ormerchantability fitness a specificpurpose
and be anywillnot liablefor direct,indirect,incidentalor
consequential damages. FLIR’s total
liabilityis islimitedtorepairor ofreplacement theproduct.Thewarrantysetforthabove
inclusiveand no otherwarranty,whetherwrittenor ororal,isexpressed implied.
X X
1 2
3
4
5
6
7
Support 439 8324;Lines:U.S.(877) International:+1 (603) 324 7800
TechnicalSupport:Option3; support@extech.com E mail:
Repair & Returns:Option4; E mail:repair@extech.com
Productspecificationsaresubjecttochangewithoutnotice
Pleasevisitourwebsiteforthe datemostupto information
www.extech.com
FLIRCommercialSystems,Inc., 9 TownsendWest,Nashua,NH03063
USA


Produkt Specifikationer

Mærke: Extech
Kategori: Måling
Model: RF30

Har du brug for hjælp?

Hvis du har brug for hjælp til Extech RF30 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måling Extech Manualer

Extech

Extech HD300 Manual

28 November 2025
Extech

Extech ET10 Manual

28 November 2025
Extech

Extech VT10 Manual

28 November 2025
Extech

Extech MA430 Manual

28 November 2025
Extech

Extech RF30 Manual

28 November 2025
Extech

Extech WQ510 Manual

28 November 2025
Extech

Extech EC150 Manual

28 November 2025
Extech

Extech RHT50 Manual

28 November 2025
Extech

Extech DT500 Manual

28 November 2025
Extech

Extech CT70 Manual

28 November 2025

Måling Manualer

Nyeste Måling Manualer

FLIR

FLIR E75 Manual

28 November 2025
Terraillon

Terraillon COACH Manual

27 November 2025
FLIR

FLIR T530 Manual

27 November 2025
FLIR

FLIR TG268 Manual

27 November 2025
Testo

Testo 558s Manual

26 November 2025
Eastron

Eastron SEM1 Manual

25 November 2025
Vevor

Vevor SC256M Manual

25 November 2025
Vevor

Vevor SD304 Manual

25 November 2025