Læs gratis den danske manual til Extron KNX 100G (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 20 personer og har en gennemsnitlig bedømmelse på 3.6 stjerner ud af 10.5 anmeldelser. Har du et spørgsmål om Extron KNX 100G, eller vil du spørge andre brugere om produktet?

Side 1/4
KNX 100G • Setup Guide
This setup guide covers the physical installation of the KNX 100G and KNXnet/IP tunneling from a PC to a KNX network during
conguration and commissioning.
The KNX 100G allows better integration of control with KNX building management systems (BMS). The product serves as a
gateway for control systems and ETS software to the KNX bus, and it is designed to be installed onto a DIN rail with a width of 1
unit (18 mm).
Power is supplied via the KNX bus; an external power supply is not necessary. The KNX bus can be accessed from any point on
the LAN. The IP address can be obtained by a DHCP server or by manual conguration. There are ve simultaneous connections
possible for access via KNXnet.
1
Figure 2. KNX 100G DIN Rail Installation
Installing Onto DIN Rail
1. Ensure the DIN rail is securely mounted onto the wall or furniture.
2. Place top rear against wall/furniture (Figure 2, 1).
3. Slide the unit down onto top of rail (Figure 2, 2).
4. Tilt the unit and snap onto the rail (Figure 2, 3).
Figure 1. KNX 100G Controls and Displays
DIN Rail
KNX 100G
Patent(s): www .extron.com/patents
33-2700-01 A
E
Prog. KNX
__.__.____
E
E
KNX 100G
KNX
Mode
IP
P/Esc
Conn
Up
Conn
Dn
e t
e t
KNX 100G
Place top rear against
wall/furniture.
Slide down the unit
onto top of rail.
Tilt the unit an
d
snap into rail.
1
2
3
KNX 100G
Pat ent(s): w ww.extron.com/pa tents
33-2700-01 A
E
KNX 100G
P
at ent(s):
www.ext ron.com/patents
33-2700-01 A
E
E
Prog. KNX
__.__.____
E
E
KNX 100G
KNX
Mode
IP
P/Esc
Conn
Up
Conn
Dn
est
e t
LAN
33-2558-01 B
www.e xtron.com/pat ents
Bottom View
I
A
B
E
G
H
C
D
F
A KNX Bus connector
B Programming Mode Button
C Programming Mode LED (Red)
D KNX LED (multicolor)
E Mode LED (multicolor)
F IP LED (multicolor)
G Button Connection Up
H Button Connection Down
I Ethernet/LAN Connector
Figure 3. KNX 100G Application Diagram
2
LED Status Indicators
C Programming Mode LED
LED STATUS Meaning
LED lights red Programming mode is active
LED Off Programming mode is not active
E Mode LED
LED STATUS Meaning
LED lights green Device is working in standard operation mode
LED lights red Programming mode is active
LED ashes green 1x...5x Programming mode is not active
Manual operation is active
The selected tunnel (1-5) is not used and free
LED ashes orange 1x...5x Programming mode is not active
Manual operation is active
The selected tunnel (1-5) is used and free
LED ashes red Programming mode is not active
Manual operation is not active
The device is not properly loaded for example after an interrupted download
F IP LED
LED STATUS Meaning
LED lights green The device has an active Ethernet link and valid IP settings.
LED lights red The device has an active Ethernet link and invalid IP settings or not yet received the IP settings by a
DHCP server.
LED ashes green IP telegram trafc
D KNX LED
LED STATUS Meaning
LED lights green KNX 100G successfully powered
LED ashes green Telegram trafc on the KNX bus
LED lights red shortly Communication failure on the KNX bus
est
est
KNX 100G
Patent(s): www.extron.com/patents
33-2700-01 A
E
Prog. KNX
__.__.____
E
KNX 100G
KNX
Mode
IP
P/Esc
Conn
Up
Conn
Dn
Ethernet
Twisted Pair
Cable
IPC P PRO
550
OV
ER
2
1
4
3
LIMIT
R
IR
1
2 3
4 5 6 7 8
Tx
Rx
T
x
Rx
RTS
CTS
COM
IR/S
ER
IAL
1
3
2
4
REL
AYS
FLE
X
I/
O
S
LIMI
T
OVE
R
eBU
S
SW
ITC HED
12 V DC
100 0
LINK
ACT
2
1
5
6
3
7
4
8
2
1
5 6
3
7
4
8
Light
Shutters
Dimmer
e
Thermostat
(Temperature)
Dimme
Volum
KNX 100G
IPCP Pro 550
IPCP
Pro 550
TLP Pro 725M
Net work
IPCP PRO 550
OVER
2
1
4
3
LIMIT
R
I
R
1
2
3
4 5 6
7
8
Tx
Rx
Tx
Rx
RTS
C
TS
COM
IR
/SE
R
IAL
1
3
2
4
REL
AYS
FLEXI/O
S
LIMIT
OV
ER
eBU
S
S
WITCH E D
12 V
DC
1000
LINK
A
CT
21
5 6
3
7
4
8
2
1
5 6
3
7
4
8
TLP Pro 725M
KNX
Bus
KNX 100G Network Installation
1. Using a certied KNX twisted pair cable, connect to the
KNX BUS located on the top of the device (see gure 3).
2. Connect an ethernet cable between the Ethernet port
located at the bottom of the KNX 100G and the local
network.
3. Congure the KNX 100G using ETS.
4. Congure your Extron Control System using the Extron
driver targeted at your congured KNX 100G.
NOTE: Engineering Tool Software (ETS) is an application
for designing, commissioning, and debugging KNX
installations. Click this to view and purchase ETS link
for your KNX setup. KNX system setup should be done
by a certied KNX professional.


Produkt Specifikationer

Mærke: Extron
Kategori: Ikke kategoriseret
Model: KNX 100G

Har du brug for hjælp?

Hvis du har brug for hjælp til Extron KNX 100G stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Extron Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer