Installation
Step 1 — Mounting
ATTENTION:
• These power supplies are not suitable for use in air handling spaces or in
wall cavities. The power supply must be located within the vicinity of the
Extron AV equipment in an ordinary location with pollution degree2, and
secured to an equipment rack within a dedicated closet, podium, or desk.
• Ces sources d’alimentation ne sont pas appropriées pour une utilisation
dans les espaces d’aération ou dans les cavités murales. Cette source
d’alimentation doit être située à proximité de l’équipement audiovisuel
d’Extron, dans un endroit ordinaire avec une pollution IEC1010 degré2,
et xé à un équipement de rack au sein d’un placard, d’une estrade ou
d’un bureau qui lui est dédié.
• The installation must be in accordance with the applicable provisions
of National Electrical Code ANSI/NFPA70, article725 and Canadian
Electrical Code part1, section16. The power supply must not be
permanently xed to building or similar structure.
• Cette installation doit toujours être en accord avec les mesures qui
s’applique au National Electrical Code ANSI/NFPA70, article725, et au
Canadian Electrical Code, partie1, section16. La source d’alimentation
ne devra pas être xée de façon permanente à une structure de bâtiment
ou à une structure similaire.
• The PI 115 is intended for indoor use only. It is to be connected only to
networks or circuits that are not routed to the outside plant or building.
• Le PI 115 est destinée à une utilisation en intérieur uniquement. Elle doit
être connectée seulement à des réseaux ou des circuits qui ne sont pas
routés au réseau ou au bâtiment extérieur.
Using the ZipClip 200
To attach the power injector to the ZipClip 200 mounting clip:
1. Insert the bottom of the power injector down into the clip, starting with one
end.
2. Pivot the other end down and press until the clip
snaps into place.
To remove the power injector from the ZipClip:
1. Press the tab (1) on the ZipClip.
2. Pivot the power injector and lift it out of the
ZipClip (2).
To fasten the tie wraps for cable strain relief:
1. Attach the power injector to the
ZipClip 200 mounting clip as described
previously.
2. Fasten the power output cords to the
ZipClip base.
a. Insert tie wraps along the notches on the
side of the power injector and through the tie
wrap anchor points on the ZipClip, then around
the cord.
b. Connect and pull the tie wraps until they are
secure. Do not over tighten.
Mounting to a Rack Shelf
These power supplies are one-quarter rack
wide. Up to four power supplies can be
mounted side by side directly onto a rack shelf.
1. Align the threaded holes in
the bottom of the power
injector with the holes
in an Extron rack shelf.
Fasten the supply to the
shelf with two
4-40 x 3/16 inch screws
(1) as shown on the
right.
2. Bolt the rack shelf to the rack (2).
Furniture Mounting
1. Attach the ZipClip to the furniture
using two or more wood screws
(included) as shown at right (1).
Make sure the clip is oriented with the
appropriate side facing the mounting
surface and with the tab accessible
from the front of the furniture.
2. Insert the power injector into the
ZipClip as described previously and
press to snap it into place (2).
(2) 4-40 x 3/16"
Sc srew
RSB 312
Rack Shelf
Ra Mountedck
1
2
E
CATx
Important Safety Instructions
This symbol, when used on the product,
is intended to alert the user of important
operating and maintenance (servicing)
instructions in the literature provided with the
equipment.
This symbol, when used on the product, is
intended to alert the user of the presence
of uninsulated dangerous voltage within the
product enclosure that may present a risk of
electric shock.
• Read these instructions.
• Keep these instructions.
• Heed all warnings.
• Follow all instructions.
• Do not use this apparatus near water.
• Clean only with a dry cloth.
• Do not block any ventilation openings. Install in accordance with the
manufacturer instructions.
• Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat.
• Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the other. A
grounding type plug has two blades and a third grounding prong. The
wide blade or the third prong is provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for replacement
of the obsolete outlet.
• Protect the power cord from being walked on or pinched, particularly at
plugs, convenience receptacles, and the point where they exit from the
apparatus.
• Use only attachments and accessories specified by the manufacturer.
• Unplug this device apparatus during lightning storms or when unused
for long periods of time.
CAUTION: Risk of electric shock. To reduce
the risk of fire or electric shock, do not expose this apparatus to
rain, moisture, dripping, splashing, or objects filled with liquids.
ATTENTION : Risque de choc électrique: Afin
de réduire les risques d’incendie ou de choc électrique, protégez
cet appareil de la pluie ou de l’humidité. Cet appareil doit être
conservé à l’abri des éclaboussures et des projections, et aucun
objet contenant un liquide, tel qu’un vase, ne doit être posé sur
l’appareil.
Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as when
the power-supply cord or plug is damaged, liquid has been spilled
or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been
dropped.
ATTENTION:
• This apparatus is a Class I product. This product must be
connected to a mains socket outlet with a protective earthing
connection.
• Cet appareil est un produit de Classe1. Ce produit doit
être connecté à une prise femelle secteur équipée d’une
connexion de mise à la terre.
The mains plug is used as the disconnect device and shall remain readily
operable.
To prevent the risk of shock, do not attempt to service this equipment
yourself because opening or removing covers may expose you to
dangerous voltage or other hazards.
ATTENTION:
Power sources • This equipment should be operated only from
the power source indicated on the product. This equipment is
intended to be used with a main power system with a grounded
(neutral) conductor. The third (grounding) pin is a safety feature.
Do not attempt to bypass or disable it.
[Source d’alimentation] • Ce matériel ne devrait être alimenté
qu’à partir de la source d’alimentation stipulée sur le produit.
Ce matériel est prévu pour être relié à un circuit d’alimentation
général doté d’un conducteur (neutre) mis à la terre. La troisième
broche (de terre) est un composant de sécurité. N’essayez pas
de l’éviter ou de la désactiver.
Power disconnection • To remove power from the equipment safely,
remove all power cords from the rear of the equipment, or the
desktop power module (if detachable), or from the power source
receptacle (wall plug).
Déconnection de l’alimentation • Pour déconnecter le matériel de
sa source d’alimentation en toute sécurité, débranchez tous les
cordons d’alimentation de l’arrière du matériel ou débranchez
l’adaptateur secteur (si débranchable) ou de la prise secteur
(prise murale).
LED Indicators
A Front panel power LED indicator —
Lights to indicate the PI 115 is
receiving power.
B Rear panel PWR LED indicator —
Indicates various power states of the
connected endpoints (see the table below).
LED State Port Status
Unlit The endpoint is not connected or cannot be powered.
Lit The endpoint is receiving power from the PI 115.
Blinking There is a power overload fault, or power allocation is exceeded.
Step 2 — Cabling
For the best performance, see Twisted Pair Recommendations on page 2.
1. Connect a network switch or an Extron
twisted pair transmitter product to the
LAN port (A) of the power injector
using a straight-through cable. The
device plugged into this connector
needs to be powered by a local power
source.
2. Connect an Extron PoE compatible
product that requires remote power
to the port (LAN+PWR OUT B) using
a straight-through cable.
3. Connect AC power to the PI115 (C).
LAN + PWR OUT
PI 115
LAN
100/240V ,50-60Hz~
0.45A MAX
PWR
A
B