Extron Quantum Ultra Manual

Extron Ikke kategoriseret Quantum Ultra

Læs gratis den danske manual til Extron Quantum Ultra (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 51 personer og har en gennemsnitlig bedømmelse på 3.5 stjerner ud af 26 anmeldelser. Har du et spørgsmål om Extron Quantum Ultra, eller vil du spørge andre brugere om produktet?

Side 1/4
Product Category
1
IMPORTANT:
Go to www.extron.com for the complete
user guide,
installation instructions,
and
specifications bef
ore connecting the
pr
oduct to the po
wer source.
Replacing the Quantum Ultra® Power Supplies
The Quantum Ultra has a primary and a redundant power supply unit (PSU) to ensure continued,
uninterrupted operation if a power supply should fail. However, if a power supply does fail, you should replace it as soon as
possible. The power supplies are hot-swappable, that is, one can be replaced while the unit is operating with the other PSU
supplying power.
NOTE: For full installation, configuration, and operation details, see the , available at Quantum Ultra User Guide
www.extron.com.
Replacing the Primary Power Supply
This section describes the procedure for replacing the primary power supply. If the redundant power supply needs to be replaced,
some additional steps are required (see on page 4).
Replacing the Redundant Power Supply
To replace the Quantum Ultra primary power supply:
1. Using a screwdriver or other tool, loosen the two thumbscrews on the power supply and the two thumbscrews on the
protective cover panel (see gure 1, 1).
ATTENTION:
Thumbscrews should be tightened with a tool after both initial installation and subsequent access to the panel.
Les vis doivent être serrées avec un outil adapté après la première installation et l’accès postérieur au panneau.
NOTE: The thumbscrews cannot be removed completely from the plates.
3
3
4
1
2
Figure 1. Unfastening the Power Supply
2. Remove the cover panel (2).
3. Rotate the primary power supply lever to the right (3) until it is in a horizontal position, parallel to the top and bottom of the
unit.
NOTE: If you are removing the , rotate lever (see figure 1, redundant power supply its 4) to the right instead of the
primary supply lever (3).
Replacing the Quantum Ultra Power Supplies (Continued)
2
4. As you rotate the lever, the power supply slides to the right. If necessary, continue sliding the PSU to the right as far as
possible (see gure 2, 1).
1
2
Figure 2. Rotating the Latch and Sliding the Primary Power Supply to the Right and Out
5. Lift the power supply up slightly and slide it toward you, out of the chassis (2).