Læs gratis den danske manual til Fantini Cosmi Sicurgas P71 (3 sider) i kategorien Gasdetektor. Denne vejledning er vurderet som hjælpsom af 41 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 21 anmeldelser. Har du et spørgsmål om Fantini Cosmi Sicurgas P71, eller vil du spørge andre brugere om produktet?

Side 1/3
36
Gas type Power
supply
Contacts
rating
Test
button
Operating
Protection
degree
P71 METHANE 230 Vac 50Hz 5(3)A - 250Vac YES (pull cord) 0 ÷ 40 °C IP42
P72 LPG 230 Vac 50Hz 5(3)A - 250Vac YES 0 ÷ 40 °C IP42
Sicurgas P71-P72
Flush mounting gas leak detectors for methane and LPG,
for civil environments
Sicurgas is a device that through a sensitive sensor, detects methane gas concentration (P71) and LPG concentration
(P72) in civil environments.
ELECTRICAL CHARACTERISTICS
Power supply: 230Vac - 50Hz.
Consumption: 3 VA.
Output through electromagnetic relays.
Contacts rating: 5(3)A - 250Vac.
STANDARDS AND APPROVALS
Complies with EN 60730-1 standards
P71 ANTHRACITE
P71B WHITE
P71C SILVER
Dimensions (mm)
115
65
37
INSTALLATION
Flush mounting in 3-module 503 embedded boxes by means of 2 screws (supplied).
METHANE is a gas lighter than air, the maximum concentration
is located near the ceiling.
Install the unit on the wall, about 30 cm from the ceiling and at a
distance from gas using device, between a minimum of 1 meter
and a maximum of 4 meters.
LPG is a gas heavier than air; the maximum concentration is
located near the floor.
Install the unit approximately 2 meters (minimum 1m, maximum
4m) from the gas using device and about 30 cm from the floor.
OPERATION
Sicurgas operates when the gas concentration in the air is much under the lower explosion limit (L.E.L.), immediately turning on the
red light.
In case of alarm, interferes as well an acoustic alarm that is going to prevent the danger. Simultaneously Sicurgas is making the relay
to interfere in order to control the gas interception valve.
Sicurgas has three warning lights:
green LED - indicates that the detector works properly;
yellow LED - indicates detector failure;
red LED - indicates the gas presence in the environment (ALARM).
The detector controls, through a relay, the normally closed (NC) and normally open (NO) valves with manual reset.
Sicurgas sensor, as all available on the market sensors, while being very selective can also participate for other substances, for
example: alcohol vapors, wine etc.
For example, during the use of wine while preparing food is possible, that the detector will enter in alarm situation. To avoid this
inconvenience, Sicurgas is equipped with an alarm silencing key (P61AE excluded), operated with:
pull cord for Sicurgas P71 for methane gas (mounted up on the wall, 30 cm from ceiling);
key under Sicurgas P72 body for LPG (mounted down on the wall, 30 cm from the floor).
N.B. silencing key must be pressed for at least 1 second.
max. 30 cm
min. 1 mt
max. 4 mt
GPL
max. 30 cm
min. 1 mt
max. 4 mt
BTICINO Living International, Living di transizione
BTICINO Light, Light Tech
BTICINO Living-light round LNA and square LNB
BTICINO Axolute
VIMAR Idea, Rondò and Plana
GEWISS Playbus e Playbus Young
AVE sistema 45, Noir, Blanc
AVE Banquise, Ave Yes
Siemens Delta Futura Graphit
Legrand Vela square and round
COMPATIBLE PLATES


Produkt Specifikationer

Mærke: Fantini Cosmi
Kategori: Gasdetektor
Model: Sicurgas P71

Har du brug for hjælp?

Hvis du har brug for hjælp til Fantini Cosmi Sicurgas P71 stil et spørgsmål nedenfor, og andre brugere vil svare dig