FERM Multimeter MMM1005

Læs gratis den danske manual til FERM MMM1005 (14 sider) i kategorien Multimeter. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 4.0 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om FERM MMM1005, eller vil du spørge andre brugere om produktet?

Side 1/14
Ferm B.V. • P.O.Box 134 • 8280 AC Genemuiden• NL • www.ferm.com 0208/28
Ferm MM-925
Digital multimeter (2)
Digitales Universalmeßgerät (4)
Digitale multimeter (6)
Multimètre digital (8)
Multímetro digital (10)
Digitala multimeter (12)
Digitaalinen multimittari (14)
Digitalt multimeter (16)
Digitale multimeter (18)
Digitális multiméter(20)
æËÊÈ·Îfi ¶ÔχÌÂÙÚÔ
(22)
ñËÙÓ‚ÓÈ ÏÛθÚËÏÂÚ
(24)
USERS MANUAL
GEBRAUCHSANWEISUNG
GEBRUIKSAANWIJZING
MODE D’EMPLOI
MODEO DE EMPLEO
BRUKSANVISNING
KÄYTTÖOHJE
BRUKSANVISNING
BRUGER VEJLEDNING
O¢∏°π∂™ Ã∏™∂ø™
HASZNÁLATI UTASÍTÁS
êìäéÇéÑëíÇé èé ùäëèãìÄíÄñàà
Art.nr. 185925
UK Subject to change
D Änderungen vorbehalten
NL Wijzigingen voorbehouden
F Sous réserve de modifications
SV Ändringar förbehålles
SU Pidätämme oikeuden muutoksiin
NO Rett till endringer forbeholdes
DK Ret til ændringer forbeholdes
ES Reservado el derecho de modificaciones
technicas
P Reservado o direito a modificações
I Con reserva di modifiche
H Változtatás jogát fenntartjuk
CZ Změny vyhrazeny
R Комлания Ferm постоянно
совершенству ет выпускаему ю ею
проедукцию. Позтому в техничесие
характеристики могут вноситься без
предварительного уведомления.
GR ηρούµε το δικαίωµα αλλαγών
2 Ferm
Product: Ferm Digital Multimeter
Type MM-925, Art. nr. 185925
Ferm, Genemuiden, The Netherlands
For a proper operation of this multimeter
please read this instruction manual care-
fully before use.
Do no apply an input which exceeds the maximum
and the measurement range.
For an accurate measurement, change the battery
when ‘ ‘appears on the display.
If the fuse needs to be replaced, a fuse of the same spe-
cification (200 mA / 250 V) must be used.
Keep the test lead away from the circuit and put the
switch into the "power off" position when the battery
needs to be changed, the fuse be replaced or the ca-
sing opened.
Do not store the multimeter in a place with extreme
temperatures or high relative humidity.
When the multimeter has not been used for a long pe-
riod of time, rotate the switch back and forth several
times in order to promote proper functioning.
Do not use volatile or corrosive cleaning agents for
the multimeter; use a soft cotton cloth with a mild de-
tergent instead.
WARNING:
Please observe the WARNINGS in this manual. Impro-
per use can lead to bodily injury.
The following legend applies to this manual:
- Dangerous voltage (Take care not to receive an
electric shock when measuring the voltage).
- Ground (Voltage between input terminal and
earth).
- Direct current (DC).
- Alternating current (AC).
- Replace fuses with the amp/Volt ratings shown (spe-
cifications).
Brief description
This multimeter has been designed to ensure the ef-
fective protection of the LCD display. The built-in
test lead ensures safe and easy use.
The multimeter can be opened by simply pressing the
one-touch button on the cover.
The multimeter can be switched off automatically by
closing the cover. This will save battery energy.
Standard features
3 1/2 digit LCD display, max. display 1999, height 11
mm.
When taking measurements in the overmeasuring
range, 'I' will appear on the display. In that case the me-
asuring range needs to be increased.
Equipped with diode checking and logic testing.
Indicates when the battery needs to be replaced.
• 9 V battery.
Outside dimensions: 139 x 75 x 26 mm.
Weight: approx. 200 g (incl. battery and test lead).
The multimeter is protected with a 230 V / 200 mA fu-
se in voltage and current measurement.
The multimeter has a 230 V AC/DC max. overvoltage
protection in resistance measurement.
Front panel lay-out:
A) Display
B) Transistor socket
C) Function switch
D) Range selector
Technical specification and operating procedure
Ambient temperature: 23 + 5 °C
Relative humidity: < 75%
1.DC Voltage
RANGE RESOLUTION
2000 mV 1 mV
20 V 10 mV
200 V 100 mV
450 V 1 V
Input resistance: 1 M
Max. input: 450 V DC
Operating procedure:
A. Put the function switch into the position.
B. Select the correct measuring range. In case of doubt,
select the maximum range. If possible, switch back to
a smaller range for a more accurate measurement.
C. Apply the test lead to the testing point.
D. Check the reading on the display.
UK
English
9 V Type 6F22
---
V
Ferm 27


Produkt Specifikationer

Mærke: FERM
Kategori: Multimeter
Model: MMM1005

Har du brug for hjælp?

Hvis du har brug for hjælp til FERM MMM1005 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Multimeter FERM Manualer

FERM

FERM MM-1000 Manual

20 September 2025
FERM

FERM MM-960 Manual

3 September 2024
FERM

FERM MM-940 Manual

14 August 2024
FERM

FERM MMM1007 Manual

6 Oktober 2022
FERM

FERM MMM1005 Manual

6 Oktober 2022

Multimeter Manualer

Nyeste Multimeter Manualer

REV

REV EM8900A Manual

21 September 2025
Testboy

Testboy TB 317 Manual

18 September 2025
Testboy

Testboy TB 318 Manual

18 September 2025
Amiko

Amiko TSC-1100 Manual

14 September 2025
Velleman

Velleman VTTEST22 Manual

13 September 2025
GW Instek

GW Instek GVM-9102 Manual

9 September 2025
GW Instek

GW Instek GDM-9042 Manual

9 September 2025
VOREL

VOREL 81783 Manual

9 September 2025