Fluke 323 Manual


Læs gratis den danske manual til Fluke 323 (2 sider) i kategorien Måleudstyr. Denne vejledning er vurderet som hjælpsom af 33 personer og har en gennemsnitlig bedømmelse på 4.0 stjerner ud af 17 anmeldelser. Har du et spørgsmål om Fluke 323, eller vil du spørge andre brugere om produktet?

Side 1/2
PN 4637502 March 2015
© 2015 Fluke Corporation. All rights reserved.
323/324/325
Clamp Meters
Quick Reference Guide
 Warning
To prevent possible electrical shock, fire, or personal
injury, read the “323/324/325 Safety Sheet” before you
use this Product.
30 0 V
CAT
60 0 V
CAT
30 0 VCAT
60 0 VCAT
325
TRUE RMS CLAMP METER
30 0 V
CAT
60 0 V
CAT
30 0 VCAT
60 0 VCAT
323
TRUE RMS CLAMP METER
30 0 V
CAT
60 0 V
CAT
30 0 VCAT
60 0 VCAT
324
TRUE RMS CLAMP METER
30 0 V
CAT
60 0 V
CAT
300 VCAT
600 VCAT
325
TRUE RMS CLAMP METER
V
CAT
60 0 V
CAT
300 VCAT
600 VCAT
325
TRUE RMS CLAMP METER
325
323, 324
300 VCAT
VV
or >30 V
V
323 V dc -
324, 325
V dc & V ac -
V
323 V ac -
20
OFF
ON V
Hz AC
DC
A
k
MAXMIN
F
FC
ON
323
324/325
ON
2:00
2:00
MIN
MAX
300 V
CAT
600 V
CAT
300 VCAT
600 VCAT
325
TRUE RMS CLAMP METER
300 V
CAT
600 V
CAT
300 VCAT
600 VCAT
325
TRUE RMS CLAMP METER
<70323
324/325 <30
325
324
323
Electrical Specifications
AC Current (Jaw)
Range 323 . . . . . . . . 400.0 A
324, 325 . . . . (40.00, 400.0) A
Resolution 323 . . . . . . . . 0.1 A
324, 325 . . . . (0.01, 0.1) A
Accuracy 323, 325 . . . . 2.0 % ±5 digits (45 – 65 Hz)
2.5 % ±5 digits (65 – 400 Hz)
324 . . . . . . . . 1.5 % ±5 digits (45 – 400 Hz)
Note: Add 2 % for position sensitivity.
DC Current with Jaw (325)
Range . . . . . . . . . . . (40.00, 400.0) A
Resolution . . . . . . . . . . . (0.01, 0.1) A
Accuracy . . . . . . . . . . . 2.0 % ± 5 digits
AC Voltage
Range . . . . . . . . . . . 600.0 V
Resolution . . . . . . . . . . . 0.1 V
Accuracy (45 – 400 Hz) . . 1.5 % ± 5 digits
DC Voltage
Range . . . . . . . . . . . 600.0 V
Resolution . . . . . . . . . . . 0.1 V
Accuracy . . . . . . . . . . . 1 % ±5 digits
Resistance
Range 323, 324 . . . . (400.0, 4000)
325 . . . . . . . . (400.0, 4000, 40000)
Resolution . . . . . . . . . . . (0.1, 1, 10)
Accuracy . . . . . . . . . . . 1 % ±5 digits
Continuity Beeper
323 . . . . . . . . 70 ≤ Ω
324/325 . . . . . 30 ≤ Ω
Capacitance (324, 325)
Range . . . . . . . . . . . (100.0, 1000) Fµ
Resolution . . . . . . . . . . . (0.1, 1) Fµ
Accuracy . . . . . . . . . . . 1 % ±4 digits
Frequency with Jaw (325)
Range . . . . . . . . . . . 5.0 to 500.0 Hz
Resolution . . . . . . . . . . . 0.1 Hz
Accuracy . . . . . . . . . . . 0.5 % ±4 digits
Trigger Level . . . . . . . . . . 5 to 10 Hz, 10 A
10 to 100 Hz, 5 A
100 to 500 Hz, 10 A
Specifications
Contact Temperature (324, 325)
Range . . . . . . . . . . . . . . -10.0 °C to 400.0 °C
Resolution . . . . . . . . . . . . . . 0.1 °C
Accuracy . . . . . . . . . . . . . . 1 % ±8 digits
Note: Temperature uncertainty (accuracy) does not include error of
the thermocouple probe.
Mechanical Specifications
Size (L x W x H) . . . . . . . . . . (207 x 75 x 34) mm
Weight
323 . . . . . . . . . . . 265 g
324 . . . . . . . . . . . 208 g
325 . . . . . . . . . . . 283 g
Environmental Specifications
Operating Temperature . . . . . -10 °C to +50 °C
Storage Temp . . . . . . . . . . . . -30 °C to +60 °C
Operating Humidity . . . . . . . . Non Condensing ( 10 °C)
90 % RH (at 10 °C to 30 °C)
75 % RH (at 30 °C to 40 °C)
45 % RH (at 40 °C to 50 °C)
(Without Condensation)
Operating Altitude . . . . . . . . . 2000 meters
Storage Altitude . . . . . . . . . . . 12,000 meters
EMI, EMC
Electromagnetic
Compatibility . . . . . . . . . . . . . Applies to use in Korea only. Class A
Equipment (Industrial Broadcasting &
Communication Equipment) [1]
[1] This product meets requirements for
industrial (Class A) electromagnetic
wave equipment and the seller or
user should take notice of it. This
equipment is intended for use in
business environments and is not to
beused in homes.
Temperature Coefficients . . . . Add 0.1 x specified accuracy for each
degree C above 28 °C or below 18 °C
Over Voltage Category . . . . . CAT IV 300 V, CAT III 600 V
Safety Compliance . . . . . . . . EN/IEC 61010-1, Pollution Degree 2
EN/IEC 61010-2-032
EN/IEC 61010-031:2002/A1:2008
Agency Approvals . . . . . . . . . Complies with CAN/CSA-C22.2
No. 61010-1, 2nd edition, including
Amendment 1.,  ,
IP Rating . . . . . . . . . . . . . . IP 30 Per IEC 60529:2001;
Non-operating
Batteries . . . . . . . . . . . . . . 2 AAA, NEDA 24A, IEC LR03
300 V
CAT
600 V
CAT
300 V
CAT
600 VCAT
325
TRUE RMS CLAMP MET ER
300VCAT
600VCAT
325
TRUE RMS CLAMP METER
Hz
Hz
324, 325 325
AAA
300VCAT
600VCAT
325
TRUE RMS CLAMP METER
324, 325
HOLD
20 V 30 V
>
300VCAT
600VCAT
325
TRUE RMS CLAMP METER
AC/DC & ZERO
AC/DC
ZERO
AC/DC
ZERO
AC/DC
ZERO 2 sec


Produkt Specifikationer

Mærke: Fluke
Kategori: Måleudstyr
Model: 323

Har du brug for hjælp?

Hvis du har brug for hjælp til Fluke 323 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måleudstyr Fluke Manualer

Fluke

Fluke 323 True RMS Manual

14 September 2024
Fluke

Fluke FEV350 Manual

3 September 2024
Fluke

Fluke 319 Manual

22 August 2024
Fluke

Fluke T150/VDE Manual

22 August 2024
Fluke

Fluke 301E Manual

30 Juli 2024
Fluke

Fluke 3002 FC Manual

30 Juli 2024
Fluke

Fluke 362 Manual

30 Juli 2024
Fluke

Fluke 369 Manual

29 Juli 2024
Fluke

Fluke T130 Manual

29 Juli 2024
Fluke

Fluke 365 Manual

28 Juli 2024

Måleudstyr Manualer

Nyeste Måleudstyr Manualer

Uni-T

Uni-T UT220 Manual

3 April 2025
Uni-T

Uni-T UT681C Manual

3 April 2025
Uni-T

Uni-T UT216C Manual

3 April 2025
Uni-T

Uni-T UT611 Manual

3 April 2025
Uni-T

Uni-T UT210D Manual

3 April 2025
Uni-T

Uni-T UT210C Manual

3 April 2025
Uni-T

Uni-T UT210B Manual

3 April 2025
Uni-T

Uni-T UT682 Manual

3 April 2025
Uni-T

Uni-T UT275 Manual

3 April 2025
Uni-T

Uni-T UT08A Manual

3 April 2025