Læs gratis den danske manual til Fujitsu AOYG45KRTA (21 sider) i kategorien Aircondition. Denne vejledning er vurderet som hjælpsom af 42 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 21.5 anmeldelser. Har du et spørgsmål om Fujitsu AOYG45KRTA, eller vil du spørge andre brugere om produktet?

Side 1/21
En-1
WARNING
• Installationofthisproductmustbedonebyexperiencedservicetechniciansor
professionalinstallersonlyinaccordancewiththismanual.Installationbynonprofes-
sionalorimproperinstallationoftheproductmaycauseseriousaccidentssuchas
injury,waterleakage,electricshock,orre.Iftheproductisinstalledindisregardof
theinstructionsinthismanual,itwillvoidthemanufacturer’swarranty.
• Toavoidgettinganelectricshock,nevertouchtheelectricalcomponentssoon
afterthepowersupplyhasbeenturnedo󰀨.Afterturningo󰀨thepower,alwayswait
10minutesormorebeforeyoutouchtheelectricalcomponents.
• Donotturnonthepoweruntilallworkhasbeencompleted.Turningonthepowerbe-
foretheworkiscompletedcancauseseriousaccidentssuchaselectricshockorre.
• Ifrefrigerantleakswhileworkisbeingcarriedout,ventilatethearea.Iftherefrigerant
comesincontactwithaame,itproducesatoxicgas.
• Installationmustbeperformedinaccordancewithregulations,codes,orstandards
forelectricalwiringandequipmentineachcountry,region,ortheinstallationplace.
• Donotusethisequipmentwithairoranyotherunspeciedrefrigerantintherefriger-
antlines.Excesspressurecancausearupture.
• Duringinstallation,makesurethattherefrigerantpipeisattachedrmlybeforeyou
runthecompressor.
Donotoperatethecompressorundertheconditionofrefrigerantpipingnotattached
properlywith3-wayvalveopen.Thismaycauseabnormalpressureintherefrigera-
tioncyclethatleadstoruptureandeveninjury.
• Wheninstallingorrelocatingtheairconditioner,donotmixgasesotherthanthe
speciedrefrigerant(R32)toentertherefrigerantcycle.
Ifairorothergasenterstherefrigerantcycle,thepressureinsidethecyclewillriseto
anabnormallyhighvalueandcauserupture,injury,etc.
• Toconnecttheindoorunitandoutdoorunit,useairconditionerpipingandcables
availablelocallyasstandardparts.Thismanualdescribesproperconnectionsusing
suchinstallationset.
• Donotmodifypowercable,useextensioncableorbranchwiring.Improperusemay
causeelectricshockorrebypoorconnection,insu󰀩cientinsulationorovercurrent.
• Donotpurgetheairwithrefrigerantsbutuseavacuumpumptovacuumtheinstallation.
• Thereisnotextrarefrigerantintheoutdoorunitforairpurging.
• UseavacuumpumpforR32orR410Aexclusively.
• Usingthesamevacuumpumpfordi󰀨erentrefrigerantsmaydamagethevacuum
pumportheunit.
• UseacleangaugemanifoldandcharginghoseforR32orR410Aexclusively.
• Donotusemeanstoacceleratethedefrostingprocessortoclean,otherthanthose
recommendedbythemanufacturer.
• Theapplianceshallbestoredinaroomwithoutcontinuouslyoperatingignitionsources
(forexample:openames,anoperatinggasapplianceoranoperatingelectricheater).
• Donotpierceorburn.
• Beawarethatrefrigerantsmaynotcontainanodour.
• Duringthepump-downoperation,makesurethatthecompressoristurnedo󰀨before
youremovetherefrigerantpiping.
Donotremovetheconnectionpipewhilethecompressorisinoperationwith3-way
valveopen.
Thismaycauseabnormalpressureintherefrigerationcyclethatleadstoruptureand
eveninjury.
• Thisapplianceisnotintendedforusebypersons(includingchildren)withreduced
physical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unless
theyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebya
personresponsiblefortheirsafety.Childrenshouldbesupervisedtoensurethatthey
donotplaywiththeappliance.
• Ifthepowercableortheconnectioncableisdamaged,itmustbereplacedbythe
manufacturer,itsserviceagentorsimilarqualiedpersonsinordertoavoidasafety
hazard.
• Keepanyrequiredventilationopeningsclearofobstruction.
CAUTION
• Fortheairconditionertoworkappropriately,installitaswritteninthismanual.
• Thisproductmustbeinstalledbyqualiedpersonnelwithacapacitycerticationof
handlingrefrigerantuids.Refertoregulationandlawsinuseoninstallationplace.
• Installtheproductbyfollowinglocalcodesandregulationsinforceattheplaceof
installation,andtheinstructionsprovidedbythemanufacturer.
• Thisproductispartofasetconstitutinganairconditioner.Theproductmustnotbe
installedaloneorbeinstalledwithnon-authorizeddevicebythemanufacturer.
• Alwaysuseaseparatepowersupplylineprotectedbyacircuitbreakeroperatingon
allwireswithadistancebetweencontactof3mmforthisproduct.
• Toprotectthepersons,ground(earth)theproductcorrectly,andusethepowercable
combinedwithanEarthLeakageCircuitBreaker(ELCB).
• Thisproductisnotexplosionproof,andthereforeshouldnotbeinstalledinexplosive
atmosphere.
• Thisproductcontainsnouser-serviceableparts.Alwaysconsultexperiencedservice
techniciansforrepairing.
• Wheninstallingpipesshorterthan3m,soundoftheoutdoorunitwillbetransferred
totheindoorunit,whichwillcauselargeoperatingsoundorsomeabnormalsound.
• Whenmovingorrelocatingtheairconditioner,consultexperiencedservicetechni-
ciansfordisconnectionandreinstallationoftheproduct.
• Donottouchthensoftheheatexchanger.Touchingtheheatexchangernscould
resultindamagetothensorpersonalinjurysuchasskinrupture.
• Anindooruniterror(errorcode:2-3)occursifanindoorunitforR410Aisconnectedto
therefrigerantsysteminaconcurrentmultipleconnectionenvironment.Inthatcase,
notetheindoormodelnamethatexperiencestheerror,andcontactourservicecentre.
AIRCONDITIONER
OUTDOORUNIT
INSTALLATION MANUAL
PARTNo.9379069960-02
1. SAFETY PRECAUTIONS
• Besuretoreadthismanualthoroughlybeforeinstallation.
• Thewarningsandprecautionsindicatedinthismanualcontainimportantinformation
pertainingtoyoursafety.Besuretoobservethem.
• Handthismanual,togetherwiththeoperationmanual,tothecustomer.Requestthe
customertokeepthemonhandforfutureuse,suchasforrelocatingorrepairingthe
unit.
WARNING
Indicatesapotentiallyorimminentlyhazardoussituation
which,ifnotavoided,couldresultindeathorseriousinjury.
CAUTION
Indicatesapotentiallyhazardoussituationthatmayresultin
minorormoderateinjuryordamagetoproperty.
[Originalinstructions] Forauthorizedservicepersonnelonly.
Contents
1. SAFETYPRECAUTIONS............................................................................1
2. PRODUCTSPECIFICATION.......................................................................3
2.1.Installationtools....................................................................................3
2.2.Accessories..........................................................................................4
2.3.Piperequirements................................................................................4
2.4.Electricalrequirements.........................................................................5
2.5.Additionalchargeamount.....................................................................5
2.6.Generalinformation..............................................................................6
3. INSTALLATIONWORK...............................................................................6
3.1.Installationdimensions.........................................................................7
3.2.Transportingtheunit.............................................................................7
3.3.Mountingtheunit..................................................................................8
3.4.Draininstallation...................................................................................8
3.5.Pipeinstallation....................................................................................8
3.6.Sealingtest.........................................................................................10
3.7.Vacuumprocess.................................................................................10
3.8.Additionalcharging............................................................................. 11
3.9.Electricalwiring................................................................................... 11
4. TESTRUN.................................................................................................14
4.1.Pre-testruncheckitems.....................................................................14
4.2.Testoperationmethod........................................................................14
4.3.Checklist.............................................................................................14
5. FINISHING.................................................................................................15
5.1.Installinginsulation.............................................................................15
5.2.Fillingwithputty..................................................................................15
6. HOWTOOPERATEDISPLAYUNIT.........................................................15
6.1.Displayunitposition............................................................................15
6.2.Descriptionofdisplayandbuttons......................................................15
7. FIELDSETTING........................................................................................16
7.1.Fieldsettingbuttons...........................................................................16
7.2.Functionsettings................................................................................16
8. EXTERNALINPUTANDOUTPUT............................................................ 17
8.1.Externalinput......................................................................................17
8.2.Externaloutput...................................................................................18
9. PUMPDOWN............................................................................................18
9.1.Preparationforpumpdown................................................................ 19
9.2.Pumpdownprocedure.......................................................................19
10. ERRORCODES........................................................................................19
10.1.Errordisplaymode...........................................................................19
10.2.Errorcodechecktable......................................................................20
EnglishDeutschFrançaisEspañolItalianoEλληvIkάPortuguêsРусский
Türkçe
Türkçe


Produkt Specifikationer

Mærke: Fujitsu
Kategori: Aircondition
Model: AOYG45KRTA

Har du brug for hjælp?

Hvis du har brug for hjælp til Fujitsu AOYG45KRTA stil et spørgsmål nedenfor, og andre brugere vil svare dig




Aircondition Fujitsu Manualer

Aircondition Manualer

Nyeste Aircondition Manualer

Stiebel Eltron

Stiebel Eltron ETS300 Manual

28 September 2025
Stiebel Eltron

Stiebel Eltron ETS600 Manual

28 September 2025
Stiebel Eltron

Stiebel Eltron ETS400 Manual

27 September 2025
Gree

Gree ERAF 0721A Manual

1 September 2025
Bosch

Bosch Cool 2000 Manual

1 September 2025
Bosch

Bosch Cool 4000 Manual

31 August 2025
Equator

Equator PAC 162R Manual

27 August 2025
Equator

Equator PAC 8000 Manual

26 August 2025
DAB

DAB ESYLINK Manual

23 August 2025