Læs gratis den danske manual til GE DCCD330EGWC (18 sider) i kategorien Tørretumbler. Denne vejledning er vurderet som hjælpsom af 13 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 7 anmeldelser. Har du et spørgsmål om GE DCCD330EGWC, eller vil du spørge andre brugere om produktet?

Side 1/18
Installation
Instructions
Electric Dryer
01
TOOLS YOU
WILL NEED
MATERIALS YOU WILL NEED
PHILLIPS SCREWDRIVER
SLIP JOINT PLIERS
LEVEL
GLOVES
SAFETY
GLASSES
DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
NOTE: Installation and service of this dryer requires basic
mechanical and electrical skills. It is your responsibility to
contact a qualified installer to make the electrical connections.
3/4" STRAIN
RELIEF
UL RECOGNIZED
4" DIA. METAL
ELBOW
Step 1 Prepare the Area and Exhaust for Installation of
New Dryer (see section 1).
Step 2 Check and Ensure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications (see section 3).
Step 3 Remove the Foam Shipping Pads (see section 1).
Step 4 Move the Dryer to the Desired Location.
Step 5 Connect the Power Supply (see section 2).
Step 6 Connect the External Exhaust (see section 4).
Step 7 Level Your Dryer (see section 5).
Step 8 Check the Operation of the Power Supply
and Venting.
Step 9 Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation, see section 6.
For Bathroom or Bedroom Installation, see section 7.
For Mobile or Manufactured Home see, section 8.
For side or bottom exhaust, see section 9.
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
FLAT BLADE SCREWDRIVER
DUCT TAPE
WARNING RISK OF FIRE
To reduce the risk of severe injury or death, follow all installation instruc-
tions.
Clothes dryer installation must be performed by a qualified installer.
Install the clothes dryer according to these instructions and in accordance
with local codes.
This dryer must be exhausted to the outdoors.
Use only 4” rigid metal ducting for exhausting the clothes dryer to the
outdoors.
Do not install or store this appliance in any location where it could be
exposed to water and or weather.
Save these instructions. (Installers: Be sure to leave these instructions with
the customer).
DO NOT install a clothes dryer with flexible plastic ducting materials. If
flexible metal (semi-rigid or foil-type) duct is installed, it must be UL listed
and installed in accordance with the instructions found in "Connecting The
Dryer To House Vent" on page 5 of this manual. Flexible venting materials
are known to collapse, be easily crushed, and trap lint. These conditions will
obstruct dryer airflow and increase the risk of fire.
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT- Save these
instructions for local inspector’s use.
IMPORTANT- Observe
all governingcodes and ordinances.
Note to Installer - Be sure to leave these
instructions with the customer.
Note to Customer - Keep these instruct-
ions with your Use and Care Book for
future reference.
Before the old dryer is removed from
service or discarded, remove the dryer
door.
Service information and the wiring dia-
gram are located in the control console.
Do not allow children on or in the appli-
ance. Close supervision of children is
necessary when the appliance is used
near children.
Install the dryer where the temperature
is above 50°F for satisfactory operation of
the dryer control system.
UL RATED
120/240V,30A
WITH 3 OR 4 PRONGS.
IDENTIFY THE PLUG
TYPE AS PER THE
HOUSE RECEPTACLE
BEFORE PURCHASING
LINE CORD.
Installation Instructions
1 PREPARING FOR INSTALLATION
OF NEW DRYER
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration
must be given to provide adequate clearance for installation and service.
2 ELECTRICAL CONNECTION
INFORMATION
TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer exhaust.
REMOVING LINT FROM WALL
EXHAUST OPENING
2
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
DO NOT E AN EXTENSION CORD OR ANUS
ADAPTER PLUG WITH THIS A LIANCE.PP
Dryer must be electrically grounded in accordance with
local codes and ordinances, or in the absence of local
codes, in accordance with the NAT NAL ELECTRI-IO
CAL C E, ANSI/NFPA NO. 70. OD
WAR NG - TO DUCE THE RISK OFNI RE
FIRE, ELECTRICAL SHOCK AND PERSONAL
I URY:NJ
ELECTRICAL REQUIREMENTS
This dryer must be connected to an individual branch circuit,
protected by the required time-delay fuses or circuit breakers. A
four or three-wire, single phase, 120/240V or 120/208V, 60Hz,
30 amp circuit is required.
If the electric supply does not meet the above specifications, then
call a licensed electrician.
GROUNDING INSTRUCTIONS
This dryer must be connected to a grounded metal, permanent
wiring system, or an equipment-grounding conductor must be run
with the circuit conductors and connected to the equipment-
grounding terminal on the appliance.
RELOCATE GREEN
GROUND SCREW
HERE
STRAIN
RELIEF
BRACKET
GREEN OR
YELLOW WIRE
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
SCREWS
(3)
HOT
WIRE
COVER
NEUTRAL
(White)
REMOVE GROUND STRAP
AND DISCARD. KEEP GREEN
GROUND SCREW
4 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH
CLOSED LOOP OR SPADE TERMINALS
WITH UPTURNED ENDS (NOT SUPPLIED).
INTERNAL DUCT
OPENING CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.
WALL
WARNING:Only a 4-conductor cord shall be used when the
appliance is installed in a location where grounding through the
neutral conductor is prohibited. Grounding through the neutral is
prohibited for the new branch-circuit installations, mobile homes,
recreational vehicles, and areas where local codes prohibit
grounding through the neutral conduction.
CONNECTING DRYER USING 4-WIRE
CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTES: SInce January 1,1996, the National Electric code requires
that the new constructions utilize a 4-wire connection to
an electric dryer
Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition
duct.


Produkt Specifikationer

Mærke: GE
Kategori: Tørretumbler
Model: DCCD330EGWC

Har du brug for hjælp?

Hvis du har brug for hjælp til GE DCCD330EGWC stil et spørgsmål nedenfor, og andre brugere vil svare dig




Tørretumbler GE Manualer

GE

GE GTD58GBPVDG Manual

17 Juni 2025
GE

GE GTD58EBPVDG Manual

17 Juni 2025
GE

GE HTX26GASWWW Manual

21 Februar 2025
GE

GE GTD42EASJWW Manual

17 Januar 2025
GE

GE GFDN110EDWW Manual

17 Januar 2025
GE

GE GFD45GSSKWW Manual

17 Januar 2025
GE

GE GFD45GSPKDG Manual

17 Januar 2025
GE

GE GTX42GASJWW Manual

9 Januar 2025
GE

GE GTDS855EDMC Manual

9 Januar 2025

Tørretumbler Manualer

Nyeste Tørretumbler Manualer