Side 1/4
Installation
Instructions
BEFORE YOU BEGIN
Read these instructions carefully and completely.
IMPORTANT Save these instructions
for local inspector’s use.
IMPORTANT Observe all governing
codes and ordinances.
Note to Installer Be sure to leave these
instructions with the consumer.
Note to Consumer Keep these instructions for
future reference.
Proper installation is the responsibility of the installer
Product failure due to improper installation is not
covered under the Warranty.
Range Hood Connection to
Wall Switch
JVX3240, JVX3300, JVX5305 and JVX5365
TOOLS NEEDED
If you have questions, call GE Appliances at 800.GE.CARES (800.432.2737).
31-11120-1 09-17 GEA
1/4” Nutdriver
Flat blade and Phillips
Head Screwdrivers
FOR YOUR SAFETY
WARNING Before beginning the installation,
switch power o at service panel and lock the
service disconnecting means to prevent power from
being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to
the service panel.
WARNING TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A Installation work and electrical wiring must be
done by qualied person(s) in accordance with
all applicable codes and standards, including
re-rated construction.
B When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
POWER SUPPLY
IMPORTANT (Please read carefully)
WARNING FOR PERSONAL SAFETY, THIS
APPLIANCE MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Codes or
prevailing local codes and ordinances.
Electrical supply
These vent hoods must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp circuit
breaker or time delay fuse.
Wiring must be 2 wire with ground.
If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
Route house wiring as close to the installation
location as possible in the ceiling or wall.
Connect the wiring to the house wiring in
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING The improper connection of the
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician
or service representative if you are in doubt whether
the appliance is properly grounded.
Wire cutter/stripper


Produkt Specifikationer

Mærke: GE
Kategori: Emhætte
Model: JVX5365SJSS

Har du brug for hjælp?

Hvis du har brug for hjælp til GE JVX5365SJSS stil et spørgsmål nedenfor, og andre brugere vil svare dig




Emhætte GE Manualer

GE

GE JVX5365SJSS Manual

6 Februar 2024
GE

GE JV376VBB Manual

30 Januar 2024
GE

GE CVW93043PDS Manual

29 Januar 2024
GE

GE JV356VAA Manual

2 Januar 2024
GE

GE ZX48AY Manual

21 December 2023
GE

GE UVW8304SPSS Manual

10 November 2023
GE

GE ZV891YSS Manual

14 Oktober 2023

Emhætte Manualer

Nyeste Emhætte Manualer