Gossen MAVOMAX RK5 Manual

Gossen Måling MAVOMAX RK5

Læs gratis den danske manual til Gossen MAVOMAX RK5 (2 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 4 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 2.5 anmeldelser. Har du et spørgsmål om Gossen MAVOMAX RK5, eller vil du spørge andre brugere om produktet?

Side 1/2
Operating Instructions
MAVOMAX 60, RK1, RK2/RK5
Interior Light Monitor . 4/12 21
The MAVO room light monitor is used wherever a constant illuminance has to be ensured. This applies, in MAX
particular, to compliance with the room classes according to DIN 6868-157 of diagnostic rooms, examination
rooms with immediate diagnostics, dental diagnostic workstations and in teleradiology, where diagnostic monitors
and light boxes for medical applications are used. For universally usable rooms with dimmable lighting, it supports
the setting of the permissible illuminance for diagnostic.
57, the MAVO can be used in order to extend the interval of constancy testing of image display devices for MAX
veiling luminance maximum contrast to 6 months. In the case of repeat measurements within the framework and
of acceptance or constancy testing, veiling luminance need not be measured again and the 60-minute waiting
time until the image display device has reached a stable state is eliminated.
Initial Start- Up
The MAVO is attached to the front edge of the monitor with the help of the double-faced tape at the bottom. MAX
The front of the MAVO must be ush mounted to the front of the monitor. Please note that the MAVO MAX MAX
can no longer be removed after attaching it to your monitor. Forcible removal of the monitoring unit will
destroy the base plate of the MAVOMAX!
The MAVO is supplied with electrical power by connecting it to either an available USB port or the included MAX
mains power pack via the permanently attached USB cable. The MAVO is designed for continuous operation MAX
and is now ready for use.
The indicates that ambient light is within the permissible range for the interpretation of ndings. The green LED
red LED indicates that the brightness is not within the permissible range.
Technical Data
Monitoring range: MAVO 60 lux), ( 50 lux), (MAX 60 (20… RK1 0… RK2/RK5 50…100 lux)
Power supply: Via permanently attached USB cable, approx. 2.75 m long
Mains power pack: 100 … 240 V, 50/60 Hz, 0.15 A, for indoor use only
Dimensions: 40 x 33 x 23 mm
Protection class: Class II per VDE 0106, part 1
Maintenance
The instrument does not require any special maintenance if used in accordance with the operating instructions. If
the instrument becomes contaminated during use, clean the surface of the housing with a slightly moistened cloth.
Avoid the use of cleansers, abrasives or solvents. If at any time your MAVO does not function to your full MAX
satisfaction, please contact our service department.
Printed in Germany • Subject to change without notice
GOSSEN Foto- und Lichtmesstechnik GmbH I Lina-Ammon-Str.22 I D-90471 Nuremberg I Germany