Load break switch 4P 400A
Technical properties
Architecture
Type of order Long thumb-grip
Number of poles 4 P
Type of pole 4 P
Type of case Fixed built-in
Reversing switch No
Controls and indicators
Motor drive integrated No
Main electrical features
Rated operational voltage Ue 380 / 415 V
Voltage
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8000 V
Electric current
Rated operational current in AC21category
B 400 A
Acceptable current rating with AC22
category A 400 A
Cut off current 30 kA
Rated current 400 A
Short-circuit current with gI-gG fuses 50 kA
Rated short-time withstand current 1s 9 kA
Thermal rated current outside of housings 400 A
Rated operational current in AC21 category
A 400 A
Acceptable current rating with AC22
category B 400 A
Rated operational current in AC23 category
A 400 A
Acceptable current rating with AC23
category B 400 A
Conventional thermal current under
enclosure at 40°C 400 A
Power
Nominal power under 440/500, 50Hz 140 kW
Nominal power under 660 V, 50 Hz 90 kW
Subject to technical modifications
Active power under 380/415 V, 50 Hz 132 kW
Total power loss under IN 57.6 W
Power loss per pole at In 14.4 W
Contact rating with 400 V in AC1 263 kW
Cover, door
Interlockable Yes
Installation, mounting
Tightening torque 20
Fixation type Back plate monting
Connection
Connection cross-sect. rigid cable 1x240mm²
Type of connection Terminal
Equipment
Number of auxiliary contacts as normally
closed contact 0
Number of auxiliary contacts as normally
open contact 0
Number of auxiliary contacts as change-
over contact 0
Width available for insulation connection 185
Motor drive optional No
Standards
Standard text IEC 60947-3
European directive WEEE concerned
Safety
Protection index IP IP00
Use conditions
Operating temperature -20…70 °C
Identification
meta_keyword
Switch disconnector;Load disconnecting switch;Main
switch;Switch;Disconnector
Subject to technical modifications


Produkt Specifikationer

Mærke: Hager
Kategori: Afbryder
Model: HA457

Har du brug for hjælp?

Hvis du har brug for hjælp til Hager HA457 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Afbryder Hager Manualer

Hager

Hager HXS999H Manual

11 August 2025
Hager

Hager HNC040H Manual

11 August 2025
Hager

Hager HIC490E Manual

11 August 2025
Hager

Hager HXW040H Manual

10 August 2025
Hager

Hager HET040JR Manual

10 August 2025
Hager

Hager HNA160U Manual

10 August 2025
Hager

Hager HTC150H Manual

9 August 2025
Hager

Hager HND401H Manual

9 August 2025
Hager

Hager HXS920H Manual

9 August 2025
Hager

Hager HYA025H Manual

9 August 2025

Afbryder Manualer

Nyeste Afbryder Manualer