Hager JK104BGSPD Manual


Læs gratis den danske manual til Hager JK104BGSPD (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 8 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 4.5 anmeldelser. Har du et spørgsmål om Hager JK104BGSPD, eller vil du spørge andre brugere om produktet?

Side 1/2
JK1 Surge Protection Instructions
Instruction leaflet for fitting 125A Surge
Protection
4 pole busbar to be fitted after fitting incomer and phase links (see
incomer instructions).
Please refer to the incomer fitting instructions for fitting of incomer links.
Ensure that all electrical connections on the incomer device are
tightened to 3.5Nm.
Ensure the copper link upper connection points are tightened to 5Nm.
JK101SPD
JK102SPD
Pozidrive
PZ2
2.5mm
8mm
Socket
GB
1ZD0 - Issue 0 -1868 1 8 9
ZD00868ZD0868
Clip the odule device 4 m surge protection to the
dinrail next to the chosen incomer. (If 3 pole
substitute the neutral connection block with the
KRN199, copper neutral link and M6 carp nut and
tighten the nut to 5Nm.
M s tightened ake ure the phase not links are fitted but
into the incomer terminals.
P KB phaslace the 663E 4 busbar pole into the e
and neutral of the and terminals main switch tighten
the main switch screws. Push the shroud of the
busbar down onto the surge device making sure to
keep it level all and tighten 8 screw terminals to
3.5Nm.
Place the copper earth component into the bottom
two cage terminals and secure to 3.5Nm.
Connect the opposite end to the enclosure using the
2 hex head high-tourqe screws to 3.5Nm.
and fit the shroud provided with the incomer kit by
cutting out the extra modules to accommodate the
surge protection device.
1. 1 x Type I+II or Type II Surge
Protection device
2. 1 x Copper Earth Link
3. 2 Hex head Earth screws x
4. 1 x KB663E Busbar (4 pole)
5. 1 x KRN199 Terminal block
6. 1 x ZB0220 M6 Carp Nut
7. 1 x Neutral link
Parts list:
The device may only be connected and installed by an electrically skilled person. National standards and safety regulations must be observed.
The device must be checked for external damage prior to installation. If any damage or other defects are detected in this check, the device must not be installed.
Its use is only permitted within the limits shown and stated in the installation instructions.
Opening or otherwise tampering with the device invalidates the warranty.
Disconnect protective g the plu before conducting insulation
testing on h system. therwise aulty remen are t e O f measu ts
possible.
Reinsert the protective in plug to the base element after insu-
lation testing.
Insulation testing


Produkt Specifikationer

Mærke: Hager
Kategori: Ikke kategoriseret
Model: JK104BGSPD

Har du brug for hjælp?

Hvis du har brug for hjælp til Hager JK104BGSPD stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Hager Manualer

Hager

Hager WXF228 Manual

10 August 2025
Hager

Hager UKM340480 Manual

10 August 2025
Hager

Hager TRC301B Manual

10 August 2025
Hager

Hager GS20109011 Manual

10 August 2025
Hager

Hager AKB42000402 Manual

10 August 2025
Hager

Hager WXT312 Manual

10 August 2025
Hager

Hager BKSAN065110 Manual

10 August 2025
Hager

Hager VR10127011 Manual

10 August 2025
Hager

Hager UKM240280 Manual

10 August 2025
Hager

Hager ESR3336029 Manual

10 August 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Waterstone

Waterstone 7800 Manual

11 December 2025
Kwikset

Kwikset 258 Manual

11 December 2025
Schlage

Schlage F170 Manual

11 December 2025
Moen

Moen Align 7565EV Manual

11 December 2025
ALNO

ALNO MC10244 Manual

11 December 2025
JET

JET TAK-ZX Manual

11 December 2025
Waterstone

Waterstone 1455 Manual

11 December 2025
Laica

Laica NE2015 Manual

11 December 2025