Hager REQ004X Manual


Læs gratis den danske manual til Hager REQ004X (6 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 44 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 22.5 anmeldelser. Har du et spørgsmål om Hager REQ004X, eller vil du spørge andre brugere om produktet?

Side 1/6
1
6LE000691A
REQ0..X, REQ1..X
Door station AUDIO 2wire
z
z
Safety instructions
Electrical equipment may only be installed and
assembled by a qualifi ed electrician in accord-
ance with the relevant installation standards,
guidelines, regulations, directives, safety and
accident prevention regulations of the country.
When installing and laying cables, always com-
ply with the applicable regulations and stand-
ards for SELV electrical circuits.
These instructions are an integral component
of the product and must be retained by the end
user.
Design and layout of the device
(5)
(4)
(1)
(2)
(3)
(6)
Figure 1: Design and layout of the device front
(1) Front plate stainless steel
(2) Microphone
(3) Door loudspeaker
(4) Twilight sensor for call button
(5) Button panel with call push-buttons
(6) Cover strip for dismantling protection
(10)
(7)
(8)
(9)
TOP
(11)
(12)
Figure 2: Design and layout of the device back
(7) Adjustment button Upwards
(8) 7-segment display
(9) Selection button
(10) Adjustment button downwards
(11) Module bus connector
(12) Connection terminal block
Function
The audio door station works in the 2wire bus sys-
tem and enables communication via sound.
Correct use
- for surface- or  ush-mounted installation
- not compatible with intercom systems of other
manufacturers
- suitable for use exterior applications
Product characteristics
- completely pre-assembled
- protected against vandalism
- with brushed 2 mm stainless steel front plate
- Name plate can be changed from the front with-
out any special tools
- One-man commissioning
- call button with acknowledge tone (can be
switched off) and tactile feedback
- call button, light release or door release can be
adjusted even without any function
- durable, homogeneous, white LED call
push-button backlighting
- Twilight controlled call push-button backlighting
with adjustable switch-on brightness level
- Opening of door station only with enclosed
opening tool
- break-proof  ush-mounted call buttons
- Loudspeaker and microphone protected against
sabotage
- Volume and microphone sensitivity settable
- Door release contact on 1 ... 10 s adjustable
- Door release without previous call adjustable in
single door systems
- Safety rope as installation aid
Operation
Establish call (ringing)
zPress the call push-button assigned to the
desired subscriber.
If con gured, the call push-button activation is
con rmed by an acknowledge tone. Addressed
indoor stations are called.
Switch-on lights
A call push-button is con gured and labelled for
lighting control (light insert supplied).
zPress the call push-button for lighting.
zIf con gured, the call push-button activation is
con rmed by an acknowledge tone. The light
contact of a line power supply is closed for the
set time.
Label call push-button
zKeep call push-button pressed on one side.
On the opposite side, the lever opening (14) is
accessible for a screwdriver.
zPosition the screwdriver in the lever opening
(13) and release the interlock (Figure 3).
zRemove cover with name plate insert.
2
(13)
Figure 3: name plate change
(13) Lever opening
zLabel name plate insert if required.
zInsert name plate insert, prepared foil or pre-
pared labelling strip into the cover and press on
cover.
Do not use any paper for the name plate insert,
since moisture and UV light will damage the
paper and labelling.
UV-resistant foil with laser printing is suitable
for labelling as well as labelling devices for
labelling strip:
- small buttons - 12 mm
- medium buttons - 30 mm
Door stations with status indication
Dis-
play
Cause Function/Lighting
duration
A subscriber is
called.
After 90 s without call
acceptance or an opera-
tion on the door station,
goes out.
A subscriber
accepts the
door call.
goes out, lights up
as long as the intercom
connection is pressed
down, max. 3 min.
The door is
unlocked.
Call not accepted:
Symbol goes out and
lights up for the un-
locking time set on the
door station.
Call accepted:
In addition to the
,
the
lights up for the un-
locking time set on the
door station. goes out
approx. 5 sec after the
symbol.
Table 1: Status indications of door station
Cleaning and care
Commercially available products for stainless
steel and car paintwork care containing a wax
component for conservation are recommended for
cleaning and care.
Do not use wire wool, wire brushes or any
similar products for cleaning. This will prevent
damage to the surface and accumulation of
ash rust.
P
P
P
Information for electricians
Installation and electrical connection
DANGER!
Touching live parts in the installation
environment can result in an electric
shock!
An electric shock can be lethal!
Before working on the device or load,
disconnect all associated circuit brea-
kers. Cover all live parts in the area!
ç
When installing door communication systems,
comply with the general safety regulations for tele-
communications systems according to VDE 0800:
- Separate routing of power and door communi-
cation cables with a minimum spacing of 10 cm
- Partitions between power and door communica-
tion cables in shared trunkings
- Use of standard telecommunications' cables, e.
g. J-Y (St) Y with 0.8 mm diameter
Bus cables
- J-Y(ST)Y or A-2Y(L)2Y
Use wrapped wire pair.
Recommendation: white/yellow
- CAT
Use wrapped wire pair.
Recommendation: orange/white
- YR
Use adjacent wires.
Mounting door station
Surface-mounted or  ush-mounted housing is
installed (see Assembly instruction housing).
The connection cables and indoor stations are
connected to the line power supply while taking
the maximum cable lengths and attenuations into
account (see operating instructions of the line power
supply).
zThe fastening elements supplied with the
ush-mounted housing must be assembled with
the nuts on the top and bottom on the threaded
bolts. The support bracket (14) of the fastening
elements must be located on the wall surface.
(14)
Figure 4: Support bracket of the fastening elements
(14) Support bracket of the fastening elements
zInsert opening tool (15) into the mounting de-
vice of the lower fastening element (16) on the
housing (Figure 5).
(15)
(16)
Figure 5: Inserted opening tool
(15) Opening tool
(16) Fixing element
zAttach the loops of the safety rope (17) to the
upper left suspension of the door station and to
the upper fastening element (18) in the housing.
Place the door station for installation onto the
opening tool (Figure 5).
(18)
(17)
Figure 6: installation position of door station
Individual call push-
button address/function
Automatic call push-
button addressing
Door speaker
volume
Microphone sensiti-
vity
Operating sig-
nal sound volume
Door release
unlocking time
Door release
function
set
door address
Camera present
Call push-button
Backlighting
settings
(switch-on bright-
ness level)
Display error
codes (max. 5 can
be saved)
Reset error codes
factory setting
Confi rm the call
push-button to be set
= Cancel
= Start addressing
...
Default setting
...
Default setting
...
= Acoustic signal off
Default setting
... Seconds
Default setting seconds
= only with door call
= also without door call 1)
Default setting
x ... x
x = received line
address
Default setting
= No camera
= with camera
Default setting: Audio
Video
...
= Off
= lowest value
= highest value
= always on
Default setting
... Error codes
= module communication
= sticking call button
= module address
= no error present
= Cancel
= Reset
= Cancel
= Reset
1) Door release functions without door call only possible
Figure 7: Overview


Produkt Specifikationer

Mærke: Hager
Kategori: Ikke kategoriseret
Model: REQ004X

Har du brug for hjælp?

Hvis du har brug for hjælp til Hager REQ004X stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Hager Manualer

Hager

Hager CEA225U Manual

10 Juni 2025
Hager

Hager CFA263U Manual

10 Juni 2025
Hager

Hager ADZ366C Manual

10 Juni 2025
Hager

Hager LLD100 Manual

12 Januar 2025
Hager

Hager GS11019016 Manual

30 December 2025
Hager

Hager EG203 Manual

30 December 2025
Hager

Hager MZN131 Manual

30 December 2025
Hager

Hager FN097E Manual

30 December 2025
Hager

Hager FN117E Manual

30 December 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer