Hager VM410AH Manual


Læs nedenfor 📖 manual på dansk for Hager VM410AH (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 17 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Hager Ltd. Hortonwood 50, Hortonwood, Telford, TF1 7FT / 01952 675 675 1
Design 30
RCCB Incomer Consumer Unit
Consumer Unit
Design 30 RCCB Incomer
For the distribution of power in a residential
application, conforming to BS EN 61439-3
including Annex ZB (16kA rating).
Design 30 is the enhanced board for use in applications where the
consumer unit is located in a living area of the dwelling and allows
compliance with BS 7671:2018;
Regulation 421.1.201 within domestic (household) applications consumer
units and similar assemblies shall comply with BS EN 61439-3 and shall
have their enclosure manufactured from a non-combustible material.
Regulation 411.3.3 additional protection by means of a 30mA RCD
Regulation 522.6.202 protection of wiring concealed in walls or partitions
with RCD 30mA.
Regulation 531.3.3 Selection of appropriate RCD. Type A RCCBs can
detect and respond to both AC and pulsating DC components.
RCCB incomer boards are generally used as sub distribution boards in
residential applications where all outgoing circuits share the same 30mA
RCD protection.
Description Size Cat ref.
Cat ref.
with Knockouts
2 Way 40A 30mA Type A RCCB Incomer 2 VM402AH VM402AHK
Con.unit,D30,6w,63A,30mA Type A RCCB 3 VM406AH VM406AHK
Con.unit,D30,8w,63A,30mA, Type A RCCB 4 VM410AH VM410AHK
Con.unit,D30,6w,100A,30mA type A RCCB 3 VM306AH VM306AHK
10 Way 100A 30mA Type A RCCB Incomer 4 VM310AH VM310AHK
14 Way 100A 30mA Type A RCCB Incomer 5 VM314AH VM314AHK
VM306 HA
Features & Benefits
- Type A RCCBs for general purpose circuits and circuits containing
equipment incorporating electronic components.
- Cable clamp – Secures supply cables on entry to main incoming
device preventing any movement being transmitted through metertails
to device.
- Square cable entry points top and bottom for use with cable trunking.
- Meter tail cable entry plate (VM04CE) provided
- Rear knockouts for ease of cable entry – Cable protector plate
(VM02CE) provided
- Rigid top wallEnhances rigidity to prevent distortion when removing
knockouts.
- Front cover retained screws – Prevents loss during installation
- Locate and hold cover allows use of both hands whilst tting cover.
- Full metal din rail – Secure and stable attachment of devices.
- Quick release clip on MCB/RCBO Allows tting and removal of
device with busbar in place.
- Optimised cabling space – Din rail positioned to provide maximum
space at top of board.
- Top mounted terminal rail makes the wiring of the neutral and earth
connections neat and simple.
- Health and safety lock allows the door to be secured with circuits
isolated during construction (via accessory see overleaf)
- Torque settings displayed inside front cover – easily accessible to
electrician during installation and maintenance.
RCCB


Produkt Specifikationer

Mærke: Hager
Kategori: Ikke kategoriseret
Model: VM410AH
Bredde: 292 mm
Dybde: 102 mm
Højde: 240 mm
Husmateriale: Stål
Monteringstype: Overflade

Har du brug for hjælp?

Hvis du har brug for hjælp til Hager VM410AH stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Hager Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer