Hager XEM510 Manual

Hager Skifte XEM510

Læs gratis den danske manual til Hager XEM510 (2 sider) i kategorien Skifte. Denne vejledning er vurderet som hjælpsom af 14 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 7.5 anmeldelser. Har du et spørgsmål om Hager XEM510, eller vil du spørge andre brugere om produktet?

Side 1/2
Interfaces LAN (10/100 Mbit)
RS485 (half-duplex,
max. 115200 baud)
Protection class ll
Overvoltage category III
IP IP2X
Connection cross
section in line with
10-25 mm² *
* Mechanical: 1.5-25 mm
(e.g. for connecting
external current
transformers)
Tightening torque
for screw terminals
2.0Nm
Weight 0.3 kg
Dimensions 88 x 70 x 65mm
Ambient temperature
in operation (direct
measurement)
With reduced measuring
current IN < 32 A (direct
measurement)
-25 °C…+45 °C
-25 °C…+55 °C
Ambient temperature
during transportation /
storage
-25 °C…+70 °C
Relative humidity (non-
condensing)
Up to 75% as an
annual average,
up to 95% on up
to 30 days/year
Max. altitude during
operation
2000 m above sea
level
Degree of polution 2
Usage Indoor use only or in a
waterproof enclosure
Mains power supply
Starting current < 25mA
Supply voltage /
frequency
110 V ~ ±10 % /
60 Hz ± 5%
or
230 V ~ ±10 % /
50 Hz ± 5%
Internal consumption
P
max
5.0 W
Measuring current circuit
for measurement category lll
Limit current I
N
/ phase 63A
Rated voltage max. 230/400 V ~
Frequency range 50/60 Hz ± 5%
A Outer conductors, L1, L2, L3 outputs
B(A) RS485 modbus RTU connection
B(B) Not used
C Connection Ethernet LAN1 (switch mode)
D Connection Ethernet LAN2 (switch mode)
E PWR: Power LED
F APP: Application LED
G NET: Network LED
H BTN: Button (reset)
I Outer conductors, L1, L2, L3 Inputs
J Neutral conductor N
7. Modbus interface
Note the following points when connecting
external devices to the RS485 Modbus RTU
interface of the Local Load Manager.
Controller:
Requirement for the cable:
Nominal voltage/wire insulation:
300V RMS
• Cable cross section: 0.25 ... 1.5mm²
• Cable type: Rigid or fl exible
Recommendation: Use AlphaWire standard
cable, designation 2466C. Alternatively, a
CAT5e cable can also be used.
Requirement for cable installation:
In the area for connecting the RS485
Modbus RTU interface on the Local Load
Manager, mechanical means must be
provided to ensure that individual wires of
the connecting cable are at least 10mm
away from live parts.
The connecting cable must be run
separately from the mains cables in the
distribution board and on the permanent
link.
The RS485 Modbus RTU interface of the
connected unit must meet the safety extra
low voltage requirements.
Power LED
Colour Status Description
Green Flashing Device is starting.
Green On Application launched correctly and running.
Orange Flashing Application on update. Try to realize an hardware reboot.
Orange On Application not launched: an issue appears in application lifecyc le. Try to
realize an hardware reboot. If system doesn’t go back to normal, please
take contact with hager support.
Red On Application / System Dead: Try to realize an hardware reboot. If system
doesn’t go back to normal, please take contact with hager support.
Application LED
Colour Status Description
Green On Installation is running.
Orange On Product not fully confi gured.
Red On Critical error occur, see hager website https://hgr.io/r/XEM520 or https://
hgr.io/r/XEM510
Orange Flashing rapidly Date and time are not synchronizing, connect to the webserver in order to
solve the issue.
Network LED
Colour Status Description
/ Off No connection.
Green On Internet connected.
Green Flashing rapidly Admin password set to default during 10 min (press between 2 and 4
seconds).
Orange On No internet connection.
Red On Network issue: confl ict on IP, no address got from DHCP server…
XEM520
Danger of death by electric shock.
Live components carry potentially fatal
voltages.
Before starting any installation or
maintenance work, switch off the power to
the distribution board and secure to prevent it
being switched on again accidentally.
Make sure that the conductors to be
connected to the meter are voltage-free.
All installation and maintenance work on this
unit must be carried out by a trained and
authorised electrician.
The Local Load Manager is supplied with
power via outer conductor L1. At least the
outer conductor L1 and neutral conductor N
need to be connected for the unit to switch on.
1. Introduction
This product makes it possible to manage a
cluster of charging stations for electric cars.
It is able to adapt the charging power
of electric vehicles according to the
consumption of the building (dynamic
management) or according to a fi xed value
(static management). It avoids an electrical
shutdown of the building due to an overload.
The product is also able to manage access
to the charging station by confi guring RFID
badges and manage di erent charging modes.
An „open“ access is accessible for the
end user, in order to check in real time the
availability of the terminals.
2. Documentation
The latest and complete documentation
is available on https://hgr.io/r/XEM510 or
https://hgr.io/r/XEM520
3. Safety instructions
4. Technical data
5. Operation of the Local Load
Manager at ambient temperature
of 55°C
The Local Load Manager must not be run
continuously at ambient temperatures of 55
°C. If such condition can be present, please
consider the usage of Current Transformer
and to install the Local Load Manager in an
appropriate environment.
8. Led statuses
6. Product description
Avoid damage to or destruction of the Local
Load Manager
Do not connect an ISDN cable to the Local
Load Managers network connection.
• Damage to or destruction of the Local
Load Manager by voltage surges on the
network cable.
If network cables are installed outside the
building, voltage surges can be caused by
lightning strike, for example.
If installed outside the building, the network
cable must be protected with suitable
overvoltage protection.
• Damage to or destruction of the Local
Load Manager by improper use.
Do not operate the Local Load Manager
outside the specified technical tolerances.
The LAN1/2 Ethernet interface of the
connected unit must meet the safety extra
low voltage requirements.
• For outdoor use, install an network isolator
on the LAN1/2 Ethernet input of the product.
Danger of death by electric shock.
Live components carry potentially fatal
voltages.
Only use the Local Load Manager in a dry
environment and keep it away from liquids.
Install the Local Load Manager only in
approved enclosures or distribution boards
downstream of the electricity supply
companys meter so that the connections for
the outer and neutral conductors are located
behind a cover or guard to prevent accidental
contact.
Before starting any installation or
maintenance work, switch off the power to
the distribution board and secure to prevent it
being switched on again accidentally.
Maintain the prescribed minimum distances
between the network cable and mains
voltage installation components or use
suitable insulation.
Danger of death by electric shock or fire Live
components carry potentially fatal voltages.
If the ambiant temperature exceed 45°C:
• Electrical protection must not exceed 32A.
External current transformers should be used
for higher currents.
The Local Load Manager must be connected
with cables that are at least 10mm² in cross
section and no less than 1m long.
Maximal modbus cable length = 10m.
B
A
1
2
3
4
1
2
3
4
Connection diagram for RS485 connector:
Pin Description Color
1 Not used
2 Com. / C/C’ / OVL Brown
3 D1 / B/B’ / (+) Green
4 D0 / A/A’ / (-) Yellow
z
Local Load Manager
6LE009017B
XEM510, XEM520
1
D
B(A)
XEM520
A
B(B)
C
E
F
G
H
J
I
HagerEnergy GmbH, Ursula-Flick-Straße 8, 49076 Osnabrück, Germany


Produkt Specifikationer

Mærke: Hager
Kategori: Skifte
Model: XEM510

Har du brug for hjælp?

Hvis du har brug for hjælp til Hager XEM510 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Skifte Hager Manualer

Hager

Hager ARF970D Manual

3 April 2025
Hager

Hager ARF920D Manual

3 April 2025
Hager

Hager ARF960D Manual

31 Marts 2025
Hager

Hager ARF906D Manual

31 Marts 2025
Hager

Hager ARF925D Manual

31 Marts 2025
Hager

Hager ARF975D Manual

31 Marts 2025
Hager

Hager HIB420M Manual

31 Marts 2025
Hager

Hager FWU00C3 Manual

6 Februar 2025
Hager

Hager UW71V Manual

6 Februar 2025
Hager

Hager ESC225 Manual

1 Januar 2025

Skifte Manualer

Nyeste Skifte Manualer