Hikvision DS-KAD706Y-S Manual


Læs gratis den danske manual til Hikvision DS-KAD706Y-S (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 13 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 7 anmeldelser. Har du et spørgsmål om Hikvision DS-KAD706Y-S, eller vil du spørge andre brugere om produktet?

Side 1/2
DS-KAD706Y-S(P)
1
3
2
1 2 3
4 5
1
4 5 6
3
2
6
4
Two-Wire Video & Audio Distributor
4
12
3
1
2
NetworkNetwork
DS-KAD706Y-S DS-KAD706Y
Door Station
UD29994B
Model Manufacturer
KPL-060M-II Channel Well Technology Co., Ltd
The detail for the power adapter contained in the DS-
KAD706Y-SP package is as follows:
MAX
MAX
MAX
MAXMAX
6W
6W
6W
6W6W
24VDC
24VDC
24VDC
24VDC24VDC
24 VDC
Power Input
24 VDC
Power Input
24AWG(0.2 mm², 9
Ω/100 m)
20AWG(0.5 mm², 3.5
Ω/100 m)
18AWG(0.8 mm², 2.5
Ω/100 m)
All
DS-KAD706Y - DS-KAD706Y-S Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
DS-KAD706Y - DS-KAD706Y Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
DS-KAD706Y-DS- KD8003Y-IME2 Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
DS-KAD706Y-DS-KH6320Y-WTE2 Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
Twisted Pair Parallel lines
Routing Path
Diagram References
Appearance
Power Indicator
Network Interface Network Indicator
Terminals Reset Button
Power Input
Wiring
Wire the devices with power supply cables as picture shown.
Distributor should be connected to any terminal of CH1 toCH6 of the device with two-wire cables.
Caution: Make sure all the related equipment is power-off during the installation.
Installation
Before you begin:
● Make sure the device in the package is in good condition.
Make sure all the related equipment is power-off during the installation.
● Check the product specification for the installation environment.
Wall Mounting
1. Fix the DIN rail onto the wall.
Note: You are required to utilize a matched DIN rail.
2. Press the red clip upward, and lock it to the DIN rail.
Tips for Cables and Installation
Cables and Wiring
When there are multiple cores in one parallel line, only one pair of closed cores are allowed to
transmit signal. It is not allowed to use multiple pair of cores in one cable to transmit signal.
When using parallel lines, it is suggested to use those with shielding layer. If dual core or
multiple core parallel lines without shielding layer are routed, stability of signal transmission
can be effected. You need to run a test before installation.
Impedance of cable should not be over suggested value, or distributor cannot transmit
enough power to indoor station or door station.
Strong electricity and weak electricity cannot be wired in the same route, they need to be wired
separately and the distance should be more than 0.5 meter.
All the cables used need to follow the restriction in the following table.
Device Installation
Installation environment (temperature, moisture etc.) needs to follow requirements in
specification or power output can be effected.
Power supply must be certified by Hikvision.
Note:
The indoor station and doorstation are not contained in
the package.
Note: The power source should be qualified and meet limited power
source or PS2 requirements according to IEC 60950-1 or IEC 62368-1 standard.


Produkt Specifikationer

Mærke: Hikvision
Kategori: Ikke kategoriseret
Model: DS-KAD706Y-S

Har du brug for hjælp?

Hvis du har brug for hjælp til Hikvision DS-KAD706Y-S stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Hikvision Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

IFM

IFM EBT004 Manual

31 Oktober 2025
Nebula

Nebula P1 Manual

31 Oktober 2025
Philips

Philips BG3470 Manual

31 Oktober 2025
IFM

IFM EBC029 Manual

31 Oktober 2025
Adventys

Adventys DTIC 6000 Manual

31 Oktober 2025
Blizzard

Blizzard wiCICLE Ion Manual

31 Oktober 2025
Adventys

Adventys GLN 3000 Manual

31 Oktober 2025
EtherWAN

EtherWAN EX46100 Manual

31 Oktober 2025
Cudy

Cudy M3600 Manual

31 Oktober 2025