Læs gratis den danske manual til IFM IG0401 (1 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 24 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 12.5 anmeldelser. Har du et spørgsmål om IFM IG0401, eller vil du spørge andre brugere om produktet?

Side 1/1
Mounting Instructions
Flush mountable tubular switches / CSA Div. 2
702797/01
Concerning Safety…ifm efector makes every effort to build a
dependable product, but every product will eventually fail. Therefore,
your equipment must be designed to prevent property damage and
personal injury if our products fail. ifm efector proximity switches are
not designed to be used as stand-alone devices to protect or guard
human life or limb.
When mounting tubular switches next to each other,
the spacing distance shown here should be maintained.
D = switch diameter
Flush mountable switches can be mounted
so that the active face is flush with a metal surface.
Any metal in front of the switch should be kept at
a distance of three times the nominal sensing range.
s = nominal sensing range
b = maximum thread length
M8 - 8mm, M12 - 8mm
M18 - 8mm, M 30 - 16mm
Sr = nominal sensing range
When mounting tubular switches opposite each other,
the spacing distance shown here should be maintained.
Two flat nuts are provided to hold
the installed switch in place.
3xs
b
D
DD
active face
active face
8 x Sr
active face
TEL: 800-441-8246 FAX: 800-329-0436
www.ifmefector.com
ifm efector
ELECTRICAL
DO NOT operate an incandescent light bulb as a load.
The current inrush when the bulb is cold can cause a
current overload.
DO NOT operate a proximity sensor directly from a voltage
supply without a load. This is a short circuit and can cause
damage. Note: insert a miniature fuse according to the tech-
nical data sheet, if specified.
WARNING
Explosion Hazard — substitution of components may
impair suitability of Class 1, Div. 2.
CAUTION
Nonmetallic enclosure does not provide grounding
between conduit connections. Use grounding type
bushing and jumper wires.
Use only ifm efector conduit adapters (U30029, U30030,
U30031) or other CSA certified conduit adapters.


Produkt Specifikationer

Mærke: IFM
Kategori: Ikke kategoriseret
Model: IG0401

Har du brug for hjælp?

Hvis du har brug for hjælp til IFM IG0401 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret IFM Manualer

IFM

IFM M9H202 Manual

8 September 2025
IFM

IFM AL1591 Manual

29 August 2025
IFM

IFM QCM110 Manual

29 August 2025
IFM

IFM AL1590 Manual

28 August 2025
IFM

IFM SMF320 Manual

28 August 2025
IFM

IFM SMF720 Manual

28 August 2025
IFM

IFM SMF620 Manual

27 August 2025
IFM

IFM VMB301 Manual

25 August 2025
IFM

IFM EVT289 Manual

22 August 2025
IFM

IFM EVC874 Manual

20 August 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Autel

Autel MaxiEV BCE100 Manual

12 September 2025
M-Audio

M-Audio iControl Manual

12 September 2025
Steinberg

Steinberg VST Live 2 Manual

12 September 2025
PCE

PCE FLEX 16-E Manual

12 September 2025
Tineco

Tineco iFloor 3 Breeze Manual

12 September 2025
V7

V7 RMWC9UV450-1N Manual

12 September 2025
Parisot

Parisot Taylor 2319LISU Manual

12 September 2025
Leen Bakker

Leen Bakker Bergen Manual

12 September 2025
Redragon

Redragon GA-200 Manual

12 September 2025