704492 / 00 10 / 2008
UK
Operating instructions
(Ex protection related part) for inductive sensors according to
EU directive 94/9/EC annex VIII (ATEX) group II, equipment category 3D/3G
2
Remarks for safe use in hazardous areas
Functions and features
Use in hazardous areas according to the classification
II 3D
(group II, category 3D, apparatus for dust atmosphere).
The requirements of the standards EN 61241-1 and EN 61241-0 are met.
Use in hazardous areas according to the classification
II 3G
(group II, category 3G, apparatus for gas atmosphere).
The requirements of the standard EN 60079-15 are met.
Marking (see unit or technical data sheet)
II 3D Ex tD A22 IP67 T80°C X Ta: 0°C...+60°C
II 3G Ex nA T6 X
Permissible operating temperature of the application (proper usage):
Ta: 0°C...+60°C
Installation / Set-up
The units must only be installed, connected and set up by qualified staff. The qualified staff
must have knowledge of protection classes, regulations and provisions for apparatus in
hazardous areas.
Check whether the classification (see "Marking" above and marking on the unit) is suitable
for the application.
Installation remarks / Installation
Adhere to the respective national regulations and provisions as well as the relevant
installation regulations.
Avoid electrostatic charging on plastic units and cables.
To avoid electrostatic charging clean the unit with a damp cloth only. Rubbing with non-
conductive materials must be strictly avoided.
To avoid electrostatic charging steps must be taken to ensure the equalisation of potential
of metal parts (plug housing, fixing elements, protective housing, etc.).
Do not mount the unit in the dust flow.
Avoid dust deposits on the units.
Protect the units and the cables efficiently against damage.
For the connections and the electrical technical data please see the unit marking or the
technical data sheet.
To avoid soiling, do not remove the connector cover until attaching the socket.
Avoid direct radiation with high UV components (sunlight). Mount the unit in a protected
place.
M12 plugs may only be opened or closed in a sufficiently clean environment.


Produkt Specifikationer

Mærke: IFM
Kategori: Ikke kategoriseret
Model: IG509A

Har du brug for hjælp?

Hvis du har brug for hjælp til IFM IG509A stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret IFM Manualer

IFM

IFM AL4032 Manual

8 Juni 2025
IFM

IFM AL4132 Manual

8 Juni 2025
IFM

IFM AL4133 Manual

7 Juni 2025
IFM

IFM AL4033 Manual

6 Juni 2025
IFM

IFM DW3003 Manual

9 April 2025
IFM

IFM IG6084 Manual

13 Marts 2025
IFM

IFM PV2102 Manual

10 Marts 2025
IFM

IFM OVP812 Manual

25 Januar 2025
IFM

IFM AE3400 Manual

25 Januar 2025
IFM

IFM DTE932 Manual

25 Januar 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer