Operating instructions
(Ex protection related part)
Inductive sensors
IG / II
80297014 / 00 09 / 2020
UK
UK
UK
UK
UK
2
Remarks for safe use in hazardous areas
Functions and features
Use in hazardous areas according to the classification
II 3D
(group II, category 3D, apparatus for dust atmosphere).
The requirements of the standards EN 60079-0 and EN 60079-31 are met.
Certificat d‘examen de type:
BVS 20 ATEX E 054 X
Certificat d‘examen IECEx de type:
IECEx BVS 20.0041X
Marking (see unit or technical data sheet)
II 3D Ex tc IIIC T80°C Dc X
Permissible operating temperature of the application (proper usage):
Ta: -20°C...+60°C
Installation / Set-up
The units must only be installed, connected and set up by qualified staff. The qualified staff
must have knowledge of protection classes, regulations and provisions for apparatus in
hazardous areas.
Check whether the classification (see „Marking“ above and marking on the unit) is suitable
for the application.
Installation remarks / Installation
Adhere to the respective national regulations and provisions as well as the relevant
installation regulations.
Avoid electrostatic charging on plastic units and cables.
To avoid electrostatic charging clean the unit with a damp cloth only. Rubbing with non-
conductive materials must be strictly avoided.
To avoid electrostatic charging steps must be taken to ensure the equalisation of potential
of metal parts (plug housing, fixing elements, protective housing, etc.).
Do not mount the unit in the dust flow.
Avoid dust deposits on the units.
Protect the units and the cables efficiently against damage.
For the connections and the electrical characteristics please see the unit marking or the
technical data sheet.
Avoid direct radiation with high UV components (sunlight). Mount the unit in a protected
place.
M12 plugs may only be opened or closed in a sufficiently clean environment.


Produkt Specifikationer

Mærke: IFM
Kategori: Ikke kategoriseret
Model: IG515A

Har du brug for hjælp?

Hvis du har brug for hjælp til IFM IG515A stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret IFM Manualer

IFM

IFM DX1041 Manual

28 Juli 2025
IFM

IFM TAD191 Manual

21 Juli 2025
IFM

IFM VVB302 Manual

20 Juli 2025
IFM

IFM UGT301 Manual

20 Juli 2025
IFM

IFM IEP201 Manual

20 Juli 2025
IFM

IFM AC2953 Manual

15 Juli 2025
IFM

IFM SU2050 Manual

11 Juli 2025
IFM

IFM SU9050 Manual

11 Juli 2025
IFM

IFM SU8651 Manual

10 Juli 2025
IFM

IFM SU2651 Manual

10 Juli 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer