IFM IN503A Manual


Læs gratis den danske manual til IFM IN503A (3 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 14 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 7.5 anmeldelser. Har du et spørgsmål om IFM IN503A, eller vil du spørge andre brugere om produktet?

Side 1/3
704303/00 10/2007
UK
Operating instructions
(Ex protection related part) for Inductive proximity switches / Capacitive
proximity switches / Photoelectric sensors / Speed monitors / Pressure
sensors / Flow sensors according to EU directive 94/9/EC Annex VIII
(ATEX) group II, equipment category 3D
2
Instructions for the safe use in hazardous areas
Function and features
Use in hazardous areas according to the classification
II 3D
(group II, category 3D, apparatus for dust atmosphere).
The requirements of the EN50014 and EN50281-1-1 standards are met.
Shock test to EN60947-5-2 with 0.5 Joule.
Marking (see unit or technical data sheet)
II 3D IP67 T = 80°C X -20°C =< Ta <= 60°C
II 3D IP65 T = 80°C X -20°C =< Ta <= 60°C
II 3D IP65 T = 95°C X -20°C =< Ta <= 60°C
Permissible operating temperature of the application (proper usage):
- 20 to + 60 °C
Installation / Set-up
The units should only be mounted, connected and set up by qualified staff. The qualified
staff must have knowledge of protection classes, regulations and provisions for apparatus in
hazardous areas.
Check whether the classification (see „Marking“ above and marking on the unit) is suitable
for the application.
Installation remarks / Mounting
Adhere to the respective national regulations and provisions as well as the relevant
installation regulations.
Avoid electrostatic charging from plastic units and cables.
To avoid electrostatic charging clean the unit with a damp cloth only.
Do not mount the unit in the dust flow.
Avoid dust deposits on the units.
Protect the units and the cables efficiently against damage.
For the connections and the electrical technical data please see the unit marking or the
technical data sheet.
Remove any cover plugs from the cable gland or the plug upon introducing the cables or
screwing on the socket to avoid soiling.


Produkt Specifikationer

Mærke: IFM
Kategori: Ikke kategoriseret
Model: IN503A

Har du brug for hjælp?

Hvis du har brug for hjælp til IFM IN503A stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret IFM Manualer

IFM

IFM AL4032 Manual

8 Juni 2025
IFM

IFM AL4132 Manual

8 Juni 2025
IFM

IFM AL4133 Manual

7 Juni 2025
IFM

IFM AL4033 Manual

6 Juni 2025
IFM

IFM DW3003 Manual

9 April 2025
IFM

IFM IG6084 Manual

13 Marts 2025
IFM

IFM PV2102 Manual

10 Marts 2025
IFM

IFM OVP812 Manual

25 Januar 2025
IFM

IFM AE3400 Manual

25 Januar 2025
IFM

IFM DTE932 Manual

25 Januar 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer