701026 / 00 03 / 2011
Installation instructions
Retro-reflective sensor
OF
UK
2
1 Functions and features
In conjunction with a prismatic reflector or reflective tape the retro-reflective sen-
sor detects objects and materials without contact and indicates their presence by
a switched signal.
Range: OFR...: 2 m; OFP... (retro-reflective sensor with polarisation filter):
800 mm; (values referred to prismatic reflector with Ø 80 mm).
2 Installation
Place prismatic reflector / reflective tape in desired position. Align the photocell
and fasten to a mounting bracket with the lock nuts provided.
Maximum range is only achieved with precise alignment.
3 Electrical connection
Disconnect power before connecting the sensor.
Connection strictly to the indications on the type label.
Core colours: BN = brown, BU = blue, BK = black
Programming of the output function by wiring according to type label.
Load of the function check output (fc output): max. 10 mA