IFM SF321A Manual


Læs gratis den danske manual til IFM SF321A (8 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 7 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 4 anmeldelser. Har du et spørgsmål om IFM SF321A, eller vil du spørge andre brugere om produktet?

Side 1/8
Operating instructions /
Mounting instructions
Flow sensor
SF***A
704181 / 02 06 / 2012
UK
2
Before installation, read the safety-related section of the operating
instructions, enclosed separately!
1 Installation
The sensor tip must be completely immersed in the medium.
In the case of horizontal pipes mount the unit from the side, if possible (fig. 1).
- When the unit is to be mounted at the bottom of the pipe, it should be free
from deposits.
- When the unit is to be mounted at the top of the pipe, it should be completely
filled with the medium to be monitored.
In the case of vertical pipes mount the unit in a place where the medium flows
upwards (fig. 2).
A
B
1
A
B
2
A: mounting bush (15 mm for units with M12 x 1 and G¼ thread; 33 mm for units with G½
thread).
B: packing washer
To avoid malfunction a minimum
distance between the flow monitor and
bends, valves or such like must be ob-
served (fig 3). Min. 5 x pipe diameter
upstream (A), min. 3 x pipe diameter
downstream (B).
D
A
B
min.
5 x D
min.
3 x D
3