IFM SF3410 Manual


Læs nedenfor 📖 manual på dansk for IFM SF3410 (5 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 18 personer og blev bedømt med 4.5 stjerner i gennemsnit af 9.5 brugere

Side 1/5
Installation Instructions
Flow sensor
SF ceramics
701777 / 03 06 / 2011
UK
2
1 Functions and features
In conjunction with the VS3000 control monitor the flow sensor monitors flows
in liquids. The sensor / control monitor combination senses whether there is a
preset flow rate (= medium flowing) or not (= medium not flowing) and provides a
switched signal.
2 Installation
The sensor tip must be completely immersed in the medium.
In the case of horizontal pipes mount the unit from the side, if possible (fig. 1).
- When the unit is to be mounted at the bottom of the pipe, it should be free
from deposits.
- When the unit is to be mounted at the top of the pipe, it should be completely
filled with the medium to be monitored.
In the case of vertical pipes mount the unit in a place where the medium flows
upwards (fig. 2).
A
B
1
A
B
2
A: mounting bush; B: packing washer
for units with thread
G¼ G½
Mounting bush (A) 15 mm 33 mm
Max. tightening torque 8 Nm 30 Nm
The thread of the mounting bush must be clean, undamaged and comply
with the standard (pipe thread to DIN ISO 228).
For sealing use the supplied PTFE packing washer.