UK
Operating instructions
(Ex protection related part) for temperature sensors according to
EU directive 2014/34/EU annex VIII (ATEX) group II, equipment
category 3D / 3G
TS502A, TS522A
706291 / 00 02 / 2019
2
Remarks for safe use in hazardous areas
Functions and features
This sensor is used for temperature measurement and is intended for industrial plants.
The technical data on the type label must be absolutely adhered to. The documentation
must be observed. For applications in which the failure of the sensor may lead to a risk for
persons corresponding safety measures must be provided.
Use in hazardous areas according to the classification
II 3D
(group II, category 3D, apparatus for dust atmosphere).
The requirements of the standards EN 60079-0 and EN 60079-31 are met.
Marking
II 3D Ex tc IIIC T135°C Dc X IP67
Use in hazardous areas according to the classification
II 3G
(group II, category 3G, apparatus for gas atmosphere).
The requirements of the standards EN 60079-0 and EN 60079-15 are met.
Marking
II 3G Ex nA IIC T4 Gc X
Permissible operating temperature of the application (proper usage):
-20 °C...+115 °C
Installation / Set-up
The units / sensors must only be installed, connected and set up by qualified staff. The
qualified staff must have knowledge of protection classes, regulations and provisions for
apparatus in hazardous areas.
Check whether the classification (see "Marking" above and marking on the unit) is suitable
for the application.
There must be no explosive atmosphere present during any task such as transport, storage,
mounting, electrical connection, commissioning, maintenance or repair.
Installation remarks / Installation
The temperature sensors must be tightly, firmly and safely connected to the measuring
application according to the current state of technology.
Adhere to the respective national regulations and provisions as well as the relevant instal-
lation regulations.
The sensor must be firmly and safely connected to its evaluation electronics to ensure a
permanent electrical connection.
The cable must be effectively protected against damage. Abrasion or sharp-edged objects
might damage the cable. This can lead to failure of the unit or make ATEX-conform operati-
on impossible.
The cable is intended for fixed laying. Minimum bending radius: 15 x cable diameter.


Produkt Specifikationer

Mærke: IFM
Kategori: Ikke kategoriseret
Model: TS522A

Har du brug for hjælp?

Hvis du har brug for hjælp til IFM TS522A stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret IFM Manualer

IFM

IFM M9H202 Manual

8 September 2025
IFM

IFM AL1591 Manual

29 August 2025
IFM

IFM QCM110 Manual

29 August 2025
IFM

IFM AL1590 Manual

28 August 2025
IFM

IFM SMF320 Manual

28 August 2025
IFM

IFM SMF720 Manual

28 August 2025
IFM

IFM SMF620 Manual

27 August 2025
IFM

IFM VMB301 Manual

25 August 2025
IFM

IFM EVT289 Manual

22 August 2025
IFM

IFM EVC874 Manual

20 August 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Avanti

Avanti FF1013D3S Manual

13 September 2025
Anybus

Anybus ProfiHub B2FO2+ Manual

13 September 2025
Liebherr

Liebherr CNsdh 762i Manual

12 September 2025
Urbanista

Urbanista Palo Alto Manual

12 September 2025
Autel

Autel MaxiEV BCE100 Manual

12 September 2025
M-Audio

M-Audio iControl Manual

12 September 2025
Steinberg

Steinberg VST Live 2 Manual

12 September 2025