Læs gratis den danske manual til Imperial IR-2-G12 (9 sider) i kategorien Komfur. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Imperial IR-2-G12, eller vil du spørge andre brugere om produktet?

Side 1/9
1
OWNERS MANUAL
INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS
®
1128 Sherborn Street ▪ Corona, CA 92879-2089 ▪ (951) 281 1830 ▪ - FAX (951) 281-1879
IR SERIES RANGES & OVENS
All Imperial Mfg. Co. equipment is manufactured for use with the type of gas specified on the rating plate
National Gas Installation Code, C /B149.1 or the Propane Installation code, CSA SA/B149.1, as applicable. Copies
may be obtained from the American Gas Association, 1515 Wilson Blvd, Arlington, VA 22209.
Instructions to be followed in case the user smells gas are to be posted in a prominent location in the
kitchen area. This information shall be obtained by contacting the local gas company or gas supplier.
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
IMPORTANT
Safe and satisfactory operation of your equipment depends to a great extent on its proper installation.
Z223.1 /B149./NFPA 54, the National Gas Installation Code, CSA 1or the Propane Installation code, C 1SA/B149. , as
applicable.
Imperial cooking appliances are restaurant grade. Ranges are free standing and available in widths from
two to six feet. A large number of different range top arrangements are assembled over one or two ovens or a
cabinet base. Installation is the same for any range top regardless of whether it has an oven below or not; in like
manner, installation is the same for all cooking equipment regardless of the top arrangement. This unit may also be
equipped with a salamander broiler. A Cheesemelter may be mounted on the high shelf as long as the Broiler is not
wider than the range.
IMPORTANT
Installing, Operating and Service Personnel:
Installation of the equipment should be performed by qualified, certified, licensed and/or authorized
personnel who are familiar with and experienced in state/local installation codes. Operation of the equipment should
be performed by qualified or authorized personnel who have read this manual and are familiar with the function of
the equipment. Service of the equipment should be performed by qualified personnel who are knowledgeable with
Imperial Ranges
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause property
damage, injury or death. Read the installation,
operating and maintenance instructions thoroughly
before installing or servicing this equipment.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER
APPLIANCE
.
2
GENERAL
(1) A manual gas shut-off valve must be installed in the gas supply (service) line ahead of the appliance and
gas pressure regulator in the gas stream for safety and ease of future service.
(2) The gas pressure regulator supplied must be installed on the appliance prior to connecting the equipment to
the gas line. Failure to install a regulator will void the equipment warranty and result in a potentially
hazardous condition.
(3) The appliance and its individual shut off valve must be disconnected from the gas supply piping system
during any pressure testing of the system at test pressures in excess of ½ PSI.
(4) The appliance must be isolated from the gas supply piping system by closing its individual manual shut off
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½
PSI.
(5) Please contact the factory, the factory representative, or a local service company to perform maintenance
and repairs.
RATING PLATE
The rating plate is located in front of the range below the oven section (7 fro om the floor). Informati n on
this plate includes the model and serial numbers. When communicating with factory about a unit or requesting
special parts or information, this data is essential for proper identification. Other information on this plate is the
BTU/hr input o the burners, operating gas pressure in inc es WC, and whetf h her the unit is orificed for natural or
propane gas. Pilot lighting instructions (ovens only) are also located in the same area. The Salamander broiler or
Cheesemelter (if provided) is supplied with its own rating plate located on the unit.
IMPERIAL COOKING APPLIANCES MUST BE CONNECTED
ONLY TO THE TYPE OF GAS IDENTIFIED ON THE RATING PLATE
CLEARANCES
The appliance area must be kept free and clear of all combustibles. This unit is design-certified for the following
installations only:
The clearances from construction for ranges and range mounted Salamander combustible and noncombustible
broiler or Cheesemelter are as follows:
Combustible Noncombustible
Back 4 0
Sides 8 0
If legs or casters are not used, the unit must extend 2 beyond the front edge of a noncombustible curb or platform.
SHIPPING DAMAGE CLAIM PROCEDURE
The equipment is inspected & crated carefully by skilled personnel before leaving factory. The transportation company
assumes full responsibility for safe delivery upon acceptance of this equipment. If shipment arrives damaged:
1. Visible loss or damage: Note on freight bill or express delivery and have signed by person making delivery.
2. File claim for damages immediately: Regardless of extent of damages.
3. Concealed loss or damage: If damage is noticed after unpacking, notify transportation company immediately and file
Concealed Damage claim with them. This should be done within fifteen (15) days from date delivery is made to
you. Retain container for inspection.


Produkt Specifikationer

Mærke: Imperial
Kategori: Komfur
Model: IR-2-G12

Har du brug for hjælp?

Hvis du har brug for hjælp til Imperial IR-2-G12 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Komfur Imperial Manualer

Komfur Manualer

Nyeste Komfur Manualer

Globe

Globe GSP18G Manual

15 Juni 2025
PKM

PKM IF2BG Manual

15 Juni 2025
Rosseto

Rosseto SM382 Manual

15 Juni 2025
Wolf

Wolf WX24 Manual

15 Juni 2025
Vulcan

Vulcan SX60 Manual

15 Juni 2025