Jøtul F 500 V3 Oslo Manual

Jøtul Komfur F 500 V3 Oslo

Læs gratis den danske manual til Jøtul F 500 V3 Oslo (32 sider) i kategorien Komfur. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Jøtul F 500 V3 Oslo, eller vil du spørge andre brugere om produktet?

Side 1/32
JøtulF500V3
Oslo
CatalyticWoodHeater
Classic and Clean Face Models
Installation and Operating Instructions
for the United States and Canada
JøtulF500V3
Oslo
The Jøtul F 500 V3 wood stove is listed
to burn solid wood only. Do not burn
any other fuels.
Read this entire manual before you
install and use this appliance.
Save these instructions for future
reference and make them available to
anyone using or servicing this wood
heater.
This wood heater contains a catalytic
combustor that requires periodic
inspection and maintenance for
proper operation. See this manual
for specific maintenance information.
It is against federal regulations to
operate this wood heater in a manner
inconsistent with the operating
instructions in this owner’s manual, or
if the catalytic element is deactivated
or removed.
Classic
Clean Face
Une version française de ce manuel est disponible au-
près de votre revendeur et sur le site www. jotul.ca.
139946-22 F 500 V3 Oslo July 2025
2
Table of Contents
CombustionSpecifications,
BuildingCodes,
SafetyNotices............................................................... 3
1. Installation
1.1AssemblybeforeInstallation................................. 4
2. Chimney and Connector Requirements
2.1ChimneyConnector................................................ 4
2.2GeneralRequirements............................................ 4
2.3MasonryChimneys................................................. 5
2.4PrefabricatedChimneys......................................... 5
2.5ChimneyHeight..................................................... 5
2.6WallPass-through................................................... 6
3. Connecting to the Chimney
3.1MasonryChimneyThimbles................................... 6
3.2HearthmountintoaMasonryFireplace................. 6
3.3PrefabricatedChimneys......................................... 7
4. Clearances to Combustibles
4.1FloorProtection...................................................... 7
4,2ClearancestoWallsandCeilings............................ 7
4.3UsingShieldstoreduceClearances....................... 7-8
4.4AlcoveInstallation.................................................. 8
4.5MobileHomeInstallation....................................... 8
5. Operation
5.1CombustionEiciency........................................... 9
5.2COEmissions.......................................................... 9
5.3WoodFuelandPerformance................................ 9-10
5.4StoveControl-FunctionsandSettings................ 10
5.5CatalyticCombustorMonitor................................ 10-11
5.6Break-inProcedure............................................... 11
5.7StartingandMaintainingaFire............................. 11-12
5.8CreosoteFormationandRemoval........................ 12
5.9AddingFuel............................................................ 12
Standards
TheJøtulF500V3Oslosolidfuelheaterhasbeentestedand
listedtoANSI/UL1482-11intheU.S.and
ANSIULC-S627-M20inCanada.
CertifiedSafetyTestsperformedby
IntertekTestingServices,Middleton,WIU.S.A.
Manufacturedby
JøtulNorthAmerica,Inc.
55HutchersonDrive
Gorham,Maine04038,U.S.A.
6. Maintenance
6.1AnnualStoveInspection........................................ 13
6.2AshRemoval........................................................... 13
6.3ChimneySystem ................................................... 13
6.4EnamelCare.......................................................... 14
6.5GlassCare/GlassReplacement.............................. 14
6.6Gaskets................................................................... 14
7. Accessories .............................................15
8. Illustrations
Figures........................................................................... 16-21
ClearanceChartandDiagrams..................................... 22-23
9. Appendix 
A.CatalyticCombustorMaintenance.......................... 24
CatalyticCombustorReplacement.......................... 25-26
B.AlternateFloorProtection....................................... 27
10. Warranty ................................................................. 28-30
WARNING !
THIS WOOD HEATER HAS A MANUFACTURER-
SET MINIMUM LOW BURN RATE THAT MUST
NOT BE ALTERED. IT IS AGAINST FEDERAL
REGULATIONS TO ALTER THIS SETTING
OR OTHERWISE OPERATE THIS WOOD
HEATER IN A MANNER INCONSISTENT WITH
OPERATING INSTRUCTIONS IN THIS MANUAL.
This heater meets the 2020 U.S.
Environmental Protection Agency’s
emission limits for wood heaters
manufactured aer May 15, 2020.
NOTE: It is normal for a new, painted stove
to emit odor and smoke during initial fires,
depending upon temperatures over time. This
is caused by the curing of high temperature
paint and manufacturing materials. This
condition can be alleviated by opening
a window or door to provide additional
ventilation. See Break-in Procedure, Sect. 5.6
for details.
This manual describes the installation and
operation of the Jøtul F 500 V3 catalytic equipped
wood heater. This heater meets the 2020 U.S.
Environmental Protection Agency’s crib wood
emission limits for wood heaters sold aer May
15, 2020. Under specific test conditions, this
heater has been shown to deliver heat at rates
ranging from 13,000 to 37,000 Btu/hr.