Jøtul GF 300 BV Allagash Manual

Jøtul Komfur GF 300 BV Allagash

Læs gratis den danske manual til Jøtul GF 300 BV Allagash (28 sider) i kategorien Komfur. Denne vejledning er vurderet som hjælpsom af 19 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 10 anmeldelser. Har du et spørgsmål om Jøtul GF 300 BV Allagash, eller vil du spørge andre brugere om produktet?

Side 1/28
1
137945_22 GF 300 BV 01/22
Installation and
Operation Instructions
Jøtul GF 300 BV Ver. 2
Allagash
Natural Vent Gas Stove
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
In the Commonwealth of Massachusetts,
a carbon monoxide (CO) detector shall
be installed in the same room as the
appliance.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or loss of life.
This appliance may be installed in an aftermarket,
permanently located, manufactured home or
mobile home, where not prohibited by local codes.
This appliance is only for use with the types of gas
indicated on the rating plate. A conversion kit is
supplied with the appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.











2
137945_22 GF 300 BV 01/22
We recommend that
our gas products be
installed and serviced by
professionals who are
certified in the U.S. by
the National Gas stove
Institute® (NFI) as NFI Gas
Specialists.
58.68%
Jøtul GF 300 BV
Installation Requirements for the
Commonwealth of Massachusetts
THIS PRODUCT MUST BE INSTALLED BY
A LICENSED MASTER OR JOURNEYMAN
PLUMBER OR GASFITTER WHEN
INSTALLED IN THE COMMONWEALTH OF
MASSACHUSETTS.
MA Approval Code G3-0817-12
1. If there is not one already present, on each
floor level where there are bedroom(s),
a carbon monoxide detector and alarm
shall be placed in the living area outside
the bedroom(s). The carbon monoxide
detector shall comply with NFPA 720
(2005 Edition).
2. A carbon monoxide detector shall:
a) Be located in the room that houses the
appliance or equipment;
b) Be either hard-wired or battery
powered or both; and
c) Shall comply with NFPA 720 (2005
Edition).
3. A Product-approved vent terminal must
be used, and if applicable, a Product-
approved air intake must be used.
Installation shall be in strict compliance
with the manufacturer’s instructions. A
copy of the installation instructions must
remain with the appliance or equipment
at the completion of the installation.
THIS OWNER’S MANUAL PROVIDES INFORMATION TO ENSURE
SAFE INSTALLATION AND EFFICIENT, DEPENDABLE OPERATION
OF YOUR GAS STOVE. PLEASE READ THESE INSTRUCTIONS IN
THEIR ENTIRETY AND MAKE THEM AVAILABLE TO ANYONE
USING OR SERVICING THIS APPLIANCE.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION
OF THIS APPLIANCE OR ITS COMPONENTS. ANY
MODIFICATION OR ALTERATION WILL VOID THE WARRANTY,
CERTIFICATION AND LISTING OF THIS APPLIANCE.
THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A
QUALIFIED SERVICE AGENCY.
Suggested Tools for
Installation and Service
External regulator (for Propane only)
Piping which complies with local code
Manual shut-off valve -
T-Handle required in Massachusetts
Sediment trap - if required by code
Tee joint
Pipe wrench
Pipe sealant
10 mm open end wrench
1/2”, 7/16” open end wrench
Phillips head screwdriver
Flat head screwdriver
1/4” nut driver
Gloves
Safety glasses
Torx T-20 screwdriver
Tin snips
PLEASE NOTE:
It is normal for smoke and odor to occur during
the initial stages of operation, depending upon
temperatures generated over time. This curing”
condition can be alleviated by promoting fresh
air circulation within the immediate vicinity of
the appliance.
Based on CSA P.4.1-15


Produkt Specifikationer

Mærke: Jøtul
Kategori: Komfur
Model: GF 300 BV Allagash

Har du brug for hjælp?

Hvis du har brug for hjælp til Jøtul GF 300 BV Allagash stil et spørgsmål nedenfor, og andre brugere vil svare dig