Jøtul GF 300 DV Allagash Manual

Jøtul Komfur GF 300 DV Allagash

Læs gratis den danske manual til Jøtul GF 300 DV Allagash (32 sider) i kategorien Komfur. Denne vejledning er vurderet som hjælpsom af 14 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 7.5 anmeldelser. Har du et spørgsmål om Jøtul GF 300 DV Allagash, eller vil du spørge andre brugere om produktet?

Side 1/32
Jøtul GF 300 DV
Allagash
Direct Vent Gas Stove
Steel Burner
v.2
Installation and
Operation Instructions
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
In the Commonwealth of Massachusetts,
a carbon monoxide (CO) detector shall
be installed in the same room as the
appliance.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or loss of life.
This appliance may be installed in an aftermarket,
permanently located, manufactured home or
mobile home, where not prohibited by local codes.
This appliance is only for use with the types of gas
indicated on the rating plate. A conversion kit is
supplied with the appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.











Conforms to ANSI Z21.88-2019 • CSA 2.33-2019,
and CAN/CGA 2.17-M91.
For stoves Serial Number 42005149 and above
137775-Rev 28 GF 300 DV 01/22
We recommend that
our gas products be
installed and serviced by
professionals who are
certified in the U.S. by
the National Fireplace
Institute® (NFI) as NFI Gas
Specialists.
65.75%
Jøtul GF 300 DV MV
THIS OWNER’S MANUAL PROVIDES INFORMATION TO
ENSURE SAFE INSTALLATION AND EFFICIENT, DEPENDABLE
OPERATION OF YOUR FIREPLACE INSERT. PLEASE READ
THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM
AVAILABLE TO ANYONE USING OR SERVICING THIS GAS
INSERT.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION
OF THIS APPLIANCE OR ITS COMPONENTS. ANY
MODIFICATION OR ALTERATION WILL VOID THE WARRANTY,
CERTIFICATION AND LISTING OF THIS APPLIANCE.
THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A
QUALIFIED SERVICE AGENCY.
Suggested Tools for
Installation and Service
External regulator (for Propane only)
Piping which complies with local code
Manual shut-off valve -
T-Handle required in Massachusetts
Sediment trap - if required by code
Tee joint
Pipe wrench
Pipe sealant
10 mm open end wrench
1/2”, 7/16” open end wrench
Phillips head screwdriver
Flat head screwdriver
1/4” nut driver
Gloves
Safety glasses
Torx T-20 screwdriver
Tin snips
Installation Requirements for the
Commonwealth of Massachusetts
THIS PRODUCT MUST BE INSTALLED BY
A LICENSED MASTER OR JOURNEYMAN
PLUMBER OR GAS-FITTER WHEN
INSTALLED IN THE COMMONWEALTH OF
MASSACHUSETTS.
1. If there is not one already present,
on each floor level where there are
bedroom(s), a carbon monoxide detector
and alarm shall be placed in the living
area outside the bedroom(s). The carbon
monoxide detector shall comply with
NFPA 720 (2005 Edition).
2. A carbon monoxide detector shall:
a) Be located in the room that houses the
appliance or equipment;
b) Be either hard-wired or battery
powered or both; and
c) Shall comply with NFPA 720 (2002
Edition).
3. A Product-approved vent terminal must
be used, and if applicable, a Product-
approved air intake must be used.
Installation shall be in strict compliance
with the manufacturer’s instructions. A
copy of the installation instructions must
remain with the appliance or equipment
at the completion of the installation.
Based on CSA P.4.1-15
PLEASE NOTE:
Initial Break-in
It is normal for smoke and odor to occur during the initial
stages of operation, depending upon temperatures
generated over time. This curing” condition can be
alleviated by promoting fresh air circulation within the
immediate vicinity of the appliance.
Operation Sound
Please be aware that cast iron and steel components
expand and contract with temperature fluctuations that
are often accompanied by “creaking” or “pinging” sounds.
This is the result of natural
thermal activity.
The optional blower fan
will also generate a slight
hum at the low setting and
progressively increase with the
velocity of forced air.


Produkt Specifikationer

Mærke: Jøtul
Kategori: Komfur
Model: GF 300 DV Allagash

Har du brug for hjælp?

Hvis du har brug for hjælp til Jøtul GF 300 DV Allagash stil et spørgsmål nedenfor, og andre brugere vil svare dig