Læs gratis den danske manual til Jøtul GF 520 DV IPI (44 sider) i kategorien Komfur. Denne vejledning er vurderet som hjælpsom af 29 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 15 anmeldelser. Har du et spørgsmål om Jøtul GF 520 DV IPI, eller vil du spørge andre brugere om produktet?

Side 1/44
1
130084_Rev A GF 520 DV IPI 11/22
Jøtul GF 520 DV IPI
Direct Vent Gas Stove
Installation and
Operation Instructions
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier,
call the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
In the Commonwealth of Massachusetts,
a carbon monoxide (CO) detector shall
be installed in the same room as the
appliance.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or loss of life.
This appliance may be installed in an aftermarket,
permanently located, manufactured home or mobile
home, where not prohibited by local codes.
This appliance is only for use with the types of gas
indicated on the rating plate. A conversion kit is
supplied with the appliance.
INSTALLER: Leave this manual with the appliance.
OWNER: Retain this manual for future reference.











Certified to ANSI Z21.88-2019 • CSA 2.33-2019
and CAN/CGA 2.17-M17.
Pilot-on-Demand Ignition
130084_Rev A GF 520 DV IPI 11/22
We recommend that
our gas products be
installed and serviced
by professionals who are
certified in the U.S. by
the National Fireplace
Institute® (NFI) as NFI
Gas Specialists.
Jøtul GF 520 DV IPI
Suggested Tools for Installation and Service
External regulator (for Propane only)
Piping which complies with local code
Manual shut-o valve -
T-Handle required in Massachusetts
Sediment trap - if required by code
Tee joint
Pipe wrench
Pipe sealant
10 mm open end wrench
1/2”, 7/16” open end wrench
Phillips head screwdriver
Flat head screwdriver
1/4” nut driver
Gloves
Safety glasses
Torx T-20 screwdriver for
Fuel Conversion
Installation Requirements for the
Commonwealth of Massachusetts
THIS PRODUCT MUST BE INSTALLED BY
A LICENSED MASTER OR JOURNEYMAN
PLUMBER OR GASFITTER WHEN
INSTALLED IN THE COMMONWEALTH
OF MASSACHUSETTS.
1. If there is not one already present, on each floor
level where there are bedroom(s), a carbon
monoxide detector and alarm shall be placed
in the living area outside the bedroom(s). The
carbon monoxide detector shall comply with
NFPA 720 (Current Edition).
2. A carbon monoxide detector shall:
a) Be located in the room that houses the
appliance or equipment;
b) Be either hard-wired or battery powered or
both; and
c) Shall comply with NFPA 720 (Current
Edition).
3. A Product-approved vent terminal must be
used, and if applicable, a Product-approved
air intake must be used. Installation shall be
in strict compliance with the manufacturer’s
instructions. A copy of the installation
instructions must remain with the appliance or
equipment at the completion of the installation.
4. A Manual gas supply line shut-o valve must
be installed.
THIS OWNER’S MANUAL PROVIDES INFORMATION
TO ENSURE SAFE INSTALLATION AND EFFICIENT,
DEPENDABLE OPERATION. PLEASE READ THESE
INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM
AVAILABLE TO ANYONE USING OR SERVICING THE
APPLIANCE.
DO NOT ATTEMPT TO ALTER OR MODIFY THE
CONSTRUCTION OF THIS APPLIANCE OR ITS
COMPONENTS. ANY MODIFICATION OR ALTERATION
WILL VOID THE WARRANTY, CERTIFICATION AND
LISTING OF THIS APPLIANCE.
THIS APPLIANCE MUST BE INSTALLED AND MAIN
TAINED BY A QUALIFIED SERVICE TECHNICIAN OR
AGENCY.
Natural Gas / 64.19%
Propane / 65.47%
Based on CSA P.4.1-15
PLEASE NOTE:
Initial Break-in
It is normal for smoke and odor to occur during the
initial stages of operation, depending upon temperatures
generated over time. This “curing” condition can be
alleviated by promoting fresh air circulation within the
immediate vicinity of the appliance. Please see page 23 for
further information.
Operation Sound
Please be aware that cast iron and steel components expand
and contract with temperature fluctuations that are often
accompanied by “creaking”
or “pinging” sounds. This is
the result of natural thermal
activity.
The blower fan will also
generate a slight hum at the
low setting and progressively
increase with the velocity of
forced air.