Kichler 15483CBR Manual

Kichler Lys 15483CBR

Læs gratis den danske manual til Kichler 15483CBR (1 sider) i kategorien Lys. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.2 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Kichler 15483CBR, eller vil du spørge andre brugere om produktet?

Side 1/1
MODEL # 15483CBR
M 8 A LR CCENT IGHT
INSTRUCTIONS PERTAINING TO A RISK OF FIRE,OR INJURY TO PERSONS
IMPORTANT SAFETY INSTRUCTIONS
Lighted lamp is HOT!
WARNING — To reduce the risk of FIRE OR INJURY TO PERSONS.
1) urn off / unplug and allow to cool before replacing lamp.T
2) Lamp gets HOT quickly!
4) Do not touch lamp or fixture if warm.
5) Do not look directly at lamp when on.
6) Keep lamp away from combustible materials.
7) Use only with wattage and lamp marked on fixture.
8) Do not touch the inner glass envelope of the lamp at any time. Use a soft cloth. Oil
from skin may damage lamp.
9) Do not operate the fixture with a damaged or missing lens.
SAFETY INSTRUCTIONS
READ THIS FIRST
KEEP THESE INSTRUCTIONS
This fixture is intended for installation in accordance with the National Electric
Code (NEC) and Local code specifications. Failure to adhere to these codes and
instructions may result in serious injury and/or property damage and will void the
warranty.
1)
2)
WARNING: This fixture is not to be installed within 10 feet (3M) of a pool, spa
or fountain.
This fixture is to be used only with a power unit (transformer) rated a maximum
of 300 W (25 AMPS) 15 volts per circuit
.
3) The #18 ga. fixture wire is not intended for direct burial or direct connection to
transformer.
4) Direct burial rated wire is to be buried a minimum of 6” (152mm) beneath the
surface of the ground. If additional Direct Burial wire is needed, contactNOTE:
your local Kichler
®
landscape distributor.
8 GA wire can be purchased in length of 250’ (76 M), 15503-BK.
10 GA wire can be purchased in length of 250’ (76 M), 15504-BK.
12 GA wire can be purchased in lengths of 100’ (30 M), 15501-BK; 250(76 M),
15502-BK; 500’ (152M), 15505-BK; and 1000’ (304 M), 15506-BK.
5) Fixture shall not use a tungsten halogen lamp unless the fixture is marked for
use with such lamps.
6) Wiring connections must be made with approved/listed wire connection device(s)
suitable for the application. Do not exceed manufacturers’ wiring combination
specifications for size and quantity of conductors.
CAUTION
WHEN INSTALLING KICHLER LANDSCAPE LIGHTING (LINE VOLTAGE OR LOW VOLTAGE), CARE SHOULD BE TAKEN TO KEEP CLEAR OF POTENTIALL Y COMBUSTIBLE
MATERIALS.
WHEN MAINTAINING THE FIXTURES, BE SURE TO REMOVE LEAVES, PINE NEEDLES, OR ANY DEBRIS THAT HAS ACCUMULATED ON THE GRASS CLIPPINGS, MULCH,
LIGHT BULB, LENS, OR BODY OF THE FIXTURE.
ASSEMBLY AND INSTALLATION
1. TURN OFF POWER.
2. Determine desired location for mounting fixture.
3. At desired location, hammer stake into ground. To avoid damage to stake, place a board on top of stake or use a rubber mallet. If
ground is hard and stake is difficult to install, make a crosscut in ground using a flat shovel.
4. wire-wayClear away area in ground at opening in stake.
5. Unscrew cowl from accent light. Cowl is removed by unscrewing set screw with counter-clockwise turns.
6. Remove housing to expose socket. Housing is removed by unscrewing the housing with counter-clockwise turns.
7. Install lamp to socket inside accent light. NOTE: Use caution when installing. Hold lamp by outer housing. DO NOT touch glass
envelope inside. If this happens, clean lamp with denatured alcohol and a lint free cloth.
8. Install cowl onto accent light housing. Cowl is installed with clockwise turns.
9. wire-wayRoute fixture cable through opening and install fixture in stake. Care should be taken to ensure wire is not twisted. Adjust
to desired aiming direction.
10. Adjust angle of accent light by loosening swivel screw.thumb
11. e nutsMake wire connections using an approved wir (not supplied.)
For warranty information please visit:
http://www.landscapelighting.com/portal/warranty_page
Para informacion de la garantia por favor visite: www.landscapelighting.com/portal/warranty_page
Date Issued: 4/27/17
IS- -US15483
Cowl
Stake
Lock Nut
Grommet
Knuckle
O-ring
Socket
Housing
Set Screw
Thumb Screw
Lens
Weʼre here to help 844-542-4537
Hrs: M-F 8am to 6:30pm EST


Produkt Specifikationer

Mærke: Kichler
Kategori: Lys
Model: 15483CBR

Har du brug for hjælp?

Hvis du har brug for hjælp til Kichler 15483CBR stil et spørgsmål nedenfor, og andre brugere vil svare dig




Lys Kichler Manualer

Kichler

Kichler 15475BKB Manual

21 December 2025
Kichler

Kichler 15483CBR Manual

20 December 2025
Kichler

Kichler 15374 Manual

20 December 2025
Kichler

Kichler 9530CMB Manual

11 December 2025
Kichler

Kichler 15005MST Manual

11 December 2025
Kichler

Kichler 15079BKT Manual

10 December 2025
Kichler

Kichler 15205MST Manual

10 December 2025
Kichler

Kichler 15268 Manual

10 December 2025
Kichler

Kichler 15079CBR Manual

10 December 2025
Kichler

Kichler 337005 Manual

10 December 2025

Lys Manualer

Nyeste Lys Manualer

Vaxcel

Vaxcel Malie W0220 Manual

21 December 2025
ET2

ET2 Alumilux E41333 Manual

21 December 2025
Vaxcel

Vaxcel W0157 Manual

21 December 2025
Vaxcel

Vaxcel Bartlett P0328 Manual

21 December 2025
Vaxcel

Vaxcel Rainier H0231 Manual

21 December 2025
Vaxcel

Vaxcel Gresham H0301 Manual

21 December 2025
Vaxcel

Vaxcel P0387 Manual

21 December 2025