2
GENERAL SPECIFICATIONS
Klein Tools CL490 is an auto-ranging true root mean square (TRMS)
digital clamp meter that measures AC/DC current via the clamp, AC/DC
voltage, DC microamps, resistance, continuity, frequency, capacitance,
tests diodes via test-leads, and temperature via a thermocouple probe.
It features high visibility, reverse contrast transflective LCD main and
secondary displays that optimize viewability in dark or bright ambient
environments.
• Environment: Indoor. DO NOT expose to moisture, rain, or snow.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <75% non-condensing
• Operating Temp: 32° to 122°F (0° to 50°C)
• Storage Temp: 14° to 122°F (-10° to 50°C)
• Accuracy: Values stated at 65° to 83°F (18° to 28°C)
• Temp Coefcient: 0.1 x (Quoted Accuracy) per °C above 28°C
or below 18°C, corrections are required when ambient working
temp is outside of Accuracy Temp range
• Dimensions: 8.46" x 3.54" x 1.50" (215 x 90 x 38 mm)
• Weight: 12.20 oz. (346 g) including batteries
• Calibration: Accurate for one year
• Auto Power-Off (APO): After approx. 5 minutes of inactivity
• Standards: IEC EN 61010-1, 61010-2-032.
IEC EN 61326-1, 61326-2-2.
Conforms to UL STD.61010-1, 61010-2-032;
Certified to CSA STD.C22.2 NO. 61010-1, 61010-2-032.
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 6.6 ft. (2m)
• Safety Rating: CATIII 600V, Class 2, Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building’s low-voltage MAINS installation.
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
5001748