Liberty Pumps 405HV Manual


Læs gratis den danske manual til Liberty Pumps 405HV (15 sider) i kategorien Pumpe. Denne vejledning er vurderet som hjælpsom af 21 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 11 anmeldelser. Har du et spørgsmål om Liberty Pumps 405HV, eller vil du spørge andre brugere om produktet?

Side 1/15
©Copyright 2014 Liberty Pumps Inc. All rights reserved
IMPORTANT:
Prior to installation, record Model, Serial Number, and
Code Number from pump nameplate for future reference.
MODEL ________________________
SERIAL ______________________
CODE ______________________
INSTALLATION
DATE _____________________ __
7000 Apple Tree Avenue
Bergen, NY 14416
Phone: (800) 543-2550
Fax: (585) 494-1839
www.libertypumps.com
Contents
1.) General Information and Safety
Guidelines
2.) Installation
3.) Maintenance and Troubleshooting
Installation Manual 7212000D
Model 404 and 405 Automatic Drain Pump
MODEL 404 Residential
115 volt
MODEL 405 Commercial 115 volt
MODEL 405HV Commercial 230 volt
Contains Certified pump
©Copyright 2014 Liberty Pumps Inc. All rights reserved 2
Side view
404
Top view
404 and 405
Dimensions are rounded to the nearest 1/8”
Before installation, read the following instructions carefully. Each Liberty pump is individually factory tested to insure proper
performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service.
Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments.
The electrical connections and wiring for a pump installation should only be made by qualified personnel.
Explosion hazard during installation. PVC cleaners, primers, and cements can release explosive vapors. These heavier than
air vapors can accumulate in the tank. The heat of soldering or sweating copper or other metal pipe can ignite these vapors
causing a violent explosion. If the unit is to be connected to copper discharge or vent piping, all solvent welded PVC joints must be
allowed to cure a minimum of 24 hours. The access cover must be removed to allow the tank to be thoroughly ventilated prior to
sweating copper pipe near the unit.
This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be
certain that it is connected to a Ground Fault Circuit Interrupter (GFCI) receptacle that meets the latest requirements per UL 943
including End of Life Provision and protection from Reverse Line-Load Miswire.
Always wear rubber boots when water is on the floor and you must unplug the pump.
DO NOT bypass grounding wires or remove ground prong from attachment plugs. DO NOT use an extension cord.
This pump requires a separate, properly fused and grounded branch circuit. Make sure the power source is properly sized for the
voltage and amperage requirements of the pump, as noted on the nameplate.
The electrical outlet shall be within the length limitations of the pump power cord, and at least 4 feet above floor level to minimize
possible hazards from flood conditions.
The installation must be in accordance with the National Electric Code, Uniform Plumbing Code, International Plumbing Code, as
well as all applicable local codes and ordinances.
Keep clear of suction and discharge openings. To prevent injury, never insert fingers into pump while it is plugged in.
DO NOT use this product for flammable or corrosive liquid.
DO NOT use this product in applications where human contact with the pumped fluid is common (such as swimming pools,
fountains, etc.)
NEVER dispose of materials such as paint thinner or other chemicals down drains, as they can chemically attack and damage
pump components, potentially causing product malfunction or failure.
Model 404 Do not use this pump in water over 140
F.
Model 405 Do not use these pumps in water over 180°F
DO NOT DO NOT use pumps in mud, sand, cement, oil or chemicals.
DO NOT modify the pump in any way.
DO NOT lift or carry pump by power cord.
DO NOT remove any tags from pump or cords.
If pump is installed during construction before power is available, it
must be protected from the environment to prevent water from
entering through the cord plug end, etc.
Fig. 1 – Typical Resident
Installation
This is a recommended
installation only.
1. General Information and Safety Guidelines
2. Installation


Produkt Specifikationer

Mærke: Liberty Pumps
Kategori: Pumpe
Model: 405HV

Har du brug for hjælp?

Hvis du har brug for hjælp til Liberty Pumps 405HV stil et spørgsmål nedenfor, og andre brugere vil svare dig




Pumpe Liberty Pumps Manualer

Pumpe Manualer

Nyeste Pumpe Manualer

Flo

Flo 79811 Manual

16 Juni 2025
Flo

Flo 79880 Manual

16 Juni 2025
Flo

Flo 79944 Manual

10 Juni 2025
Flo

Flo 79771 Manual

9 Juni 2025
Flo

Flo 79812 Manual

9 Juni 2025
Flo

Flo 79772 Manual

9 Juni 2025
Flo

Flo 79775 Manual

9 Juni 2025
Flo

Flo 79773 Manual

9 Juni 2025
Flo

Flo 79774 Manual

9 Juni 2025
Flo

Flo 79810 Manual

9 Juni 2025