Læs gratis den danske manual til Little Giant T1500 (2 sider) i kategorien Pumpe. Denne vejledning er vurderet som hjælpsom af 4 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 2.5 anmeldelser. Har du et spørgsmål om Little Giant T1500, eller vil du spørge andre brugere om produktet?

Side 1/2
T-SERIES
TORPEDO PUMP
EN
ENGLISH
This instruction sheet provides you with the information required
to safely own and operate your Cal Pump product. Retain these
instructions for future reference.
This Cal Pump product is of the highest quality workmanship and
material, and has been engineered to give you long and reliable
service. Cal Pump products are carefully tested, inspected, and
packaged to ensure safe delivery and operation. Please examine
your item(s) carefully to ensure that no damage occurred during
shipment. If damage has occurred, please contact the place
of purchase. They will assist you in replacement or repair, if
required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE
YOUR CAL PUMP PRODUCT. KNOW THE PRODUCT’S
APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL
SAFETY INFORMATION. FAILURE TO COMPLY WITH THESE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE!
DESCRIPTION
WARNING
The T-series torpedo pumps are designed for use in water displays,
ponds, waterfalls, aeration applications, and to power large bio-
filters. They come with a 20-foot power cord (40-foot on models
T7500 and T10000) and can be used in or out of water.
SAFETY GUIDELINES
WARNING
The National Electric Code and most local codes require that a
ground fault circuit interrupter (GFCI) be installed in the branch
circuit feeding your pump. For your own safety we urge you to
comply with this regulation.
DO NOT use extension cords or splices with submersible pumps.
WARNING! Risk of electrical shock. This pump is supplied with
a grounding conductor and grounding–type attachment plug.
To reduce the risk of electrical shock, connect only to a properly
grounded, grounding–type receptacle with ground fault circuit
interrupter (GFCI).
Do not lift, carry, or support the pump by its power cord.
Do not use to pump flammable, corrosive, gaseous, or explosive
liquids.
Do not run the pump dry.
INSTALLATION AND OPERATION
WARNING
WARNING: Before connecting the pump to the power source, verify
that the power source is of the same voltage and frequency listed
on the pump.
NOTE: The pump may be mounted out of water, below water line
in any position. When mounting the pump out of water, the intake
must remain flooded at all times.
1
NOTE: The PC50 power control center can be used with the T1500
and the T4000, and is available through your dealer.
1. Ensure that the maximum temperature of the pumped liquid will
not exceed 86˚F (30˚C) in continuous operation.
2. If the bottom of the pond is sandy or muddy, install the pump
suspended from a rope or chain or install it on a suitable base
to prevent its intake from clogging.
3. To facilitate pump priming, connect and submerge the inlet
hose, then fill the volute chamber by sinking the pump with its
discharge outlet facing up.
4. Complete the discharge connections.
5. Check that the power cable and/or socket are not tampered
with or damaged.
6. Start the pump by plugging it into a properly grounded,
grounding–type receptacle. There is no on/off switch.
MAINTENANCE
WARNING
WARNING: Before working on the pump, unplug the power cord
from the receptacle.
CAUTION: The power cord must not be used to lift or carry the
pump. To lower or lift the pump from pond, attach a rope to the
handle.
CAUTION: This pump is factory-sealed. Do not disassemble it. This
will void the warranty.
1. The pump requires cleaning periodically. If a reduction in
flow is noticed, large debris may have entered and lodged in
the pump and/or the impeller. If so, remove the hose fittings,
backflush the pump, and remove the debris from the suction
end of pump.
2. At the end of the season, remove the pump from the water and
clean it.
3. In freezing temperatures, remove the pump from the water
and drain it. Do not leave the pump in a frozen body of water,
or with any residual water left in the pump. Store the pump in
a bucket of water to keep the seals from drying out. Run the
pump once a week in the bucket to keep the seals from sticking
together.
4. At the start of the next season, we recommend the impeller
be manually rotated, by using a small screwdriver, before
installing in your pond.
Franklin Electric Co., Inc.
P. O. Box 12010
Oklahoma City, OK 73157-2010
888-956-0000
www.lg-outdoor.com
customerservice@lgpc.com


Produkt Specifikationer

Mærke: Little Giant
Kategori: Pumpe
Model: T1500

Har du brug for hjælp?

Hvis du har brug for hjælp til Little Giant T1500 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Pumpe Little Giant Manualer

Pumpe Manualer

Nyeste Pumpe Manualer

ProFlo

ProFlo PF92331 Manual

1 Januar 2026
ProFlo

ProFlo PF92341 Manual

31 December 2026
Liberty Pumps

Liberty Pumps PRG101M Manual

31 December 2026
ProFlo

ProFlo PF93782 Manual

31 December 2026
ProFlo

ProFlo PF92511 Manual

30 December 2026
ProFlo

ProFlo PF92952 Manual

30 December 2026
ProFlo

ProFlo PF92017 Manual

30 December 2026
Liberty Pumps

Liberty Pumps LE41A-2 Manual

30 December 2026
ProFlo

ProFlo PF93781 Manual

30 December 2026
ProFlo

ProFlo PF92352 Manual

30 December 2026