Liberty Pumps X8 Manual


Læs gratis den danske manual til Liberty Pumps X8 (4 sider) i kategorien Pumpe. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 4.0 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Liberty Pumps X8, eller vil du spørge andre brugere om produktet?

Side 1/4
IMPORTANT: All Liberty Pumps systems are supplied with their own separate
Installation/Operation/Maintenance manuals. Ensure receipt of these
manuals, and that they are read and understood prior to installation. For
questions, call Liberty Pumps customer service at 1-800-543-2550.
Installer: Manual must remain with owner or
system operator/maintainer.
Record information:
System:
7000 Apple Tree Avenue
Bergen, NY 14416
ph: 1-800-543-2550
fax: 1-585-494-1839
www.LibertyPumps.com
Keep this manual handy for future reference.
For replacement manual, visit LibertyPumps.com,
or contact Liberty Pumps.
Retain dated sales receipt for warranty.
Model(s):
Serial(s):
Date Code:
Install Date:
Installation Manual
7264000H
Copyright © Liberty Pumps, Inc. 2025
All rights reserved.
8” Basin Extension for Pro-Series Systems
Models
X8
For Pro370 and Pro380 Systems
X8-D
For Pro680 Systems
Features
•8 Molded Extension
Rubber Gasket Seal
Sixteen Stainless Steel Studs and Flange
Nuts
Discharge Pipe Extenders
Pro370
Pro380
Pro680
2 | EN Copyright © Liberty Pumps, Inc. 2025
All rights reserved. 7264000H
Contents
Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 | EN
X8 and X-D Extension Installation . . . . . . . . . . . . . . . 2 | EN
QuickTree (Float Tree) . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Safety Guidelines
Safety Precautions
Single-phase 208/230V pumps shall only be operated without
the float switch by using the circuit breaker or panel
disconnect.
Energizing the control panel or breaker for the first time is
potentially dangerous. Licensed electrical personnel should
be present when the panel or breaker is energized for the first
time. If faults caused by damage or poor installation practices
have not been detected, serious damage, injury or death can
result when power is applied.
X8 and X-D Extension Installation
Before installing the X8 or X8-D basin extension, the pump and
cover must be removed from an assembled Pro-Series system.
1. Remove the small access cover that is secured by 6 fasteners.
2. Remove the QuickTree
®
(float rod and floats) from the basin
by lifting the unit out of its holder.
3. Unscrew the fasteners securing the main cover to the tank. In
order to remove the main cover, it must be separated from
the PVC discharge pipe. This can be done by rotating the
cover back and forth while pulling upward.
Re-assembly:
1. The short length of pipe and the coupling must be “glued” to
the current discharge pipe(s).
2. Place the pump(s) with pipe into the basin and position it
within the torque stops. (The torque stops are the three round
pockets located at the bottom of the basin.) Each leg of the
pump should be inside one of the pockets.
3. Install the threaded stainless steel studs in tank (finger-tight)
until they bottom out in the threaded inserts. Standard
systems use 8 studs; XL systems require 16 for proper sealing.
4. The rubber gasket seal can now be placed over the studs and
seated onto the tank’s rim.
4a. For 8 bolt systems, it is highly recommended that
the installer apply liberal amounts of sealant (such
as silicone) on both sides of the rubber gasket seal
surface to ensure proper sealing.
5. Lower the extension over the studs until it is firmly seated on
the rubber gasket seal.
6. Install the stainless steel flange nuts on the studs and torque
to 40 in-lbs. IMPORTANT: Do not over tighten.
7. Re-attach the main cover. To facilitate assembly, wet the PVC
pipe with soapy water and insert into the rubber seal under
the cover. The cover can be twisted back and forth while
pushing down until the cover meets the extension. Re-attach
the cover with the same screws that were removed. Note:
XL-systems will have 16 screws.
8. A new, longer QuickTree rod is provided with the X8/X8-D
extension. Remove the floats from the original QuickTree rod
by loosening the screw on the clamp. For systems with an
optional alarm, two floats need to be removed.
9. Re-attach the float(s) to the new, longer QuickTree
rod
referencing Figure 5 or Figure 6 (according to system).
IMPORTANT: It is critical that the tether length remains the
same after re-installation. The tether length is the cord
distance from the clamp to the top of the float ball.
This safety alert symbol is used in the manual
and on the pump to alert of potential risk for
serious injury or death.
This safety alert symbol identifies risk of
electric shock. It is accompanied with an
instruction intended to minimize potential risk
of electric shock.
This safety alert symbol identifies risk of fire.
It is accompanied with an instruction intended
to minimize potential risk of fire.
This safety alert symbol identifies risk of
serious injury or death. It is accompanied
with an instruction intended to minimize
potential risk of injury or death.
This safety alert symbol identifies battery
hazards. It is accompanied with an instruction
intended to minimize potential risk from the
battery.
Warns of hazards which if not avoided will
result in serious injury or death.
Warns of hazards which if not avoided could
result in serious injury or death.
Warns of hazards which if not avoided could
result in minor or moderate injury.
Signals an important instruction related to the
pump. Failure to follow these instructions
could result in pump failure or property
damage.
Read every supplied manual before using this
product. Specifications are subject to change
without notice. Follow all the safety
instructions in manual(s) and on the pump.
Failure to do so could result in serious injury or
death.
W ARNING
RISK OF ELECTRIC SHOCK
W ARNING
RISK OF SERIOUS INJURY OR DEATH


Produkt Specifikationer

Mærke: Liberty Pumps
Kategori: Pumpe
Model: X8

Har du brug for hjælp?

Hvis du har brug for hjælp til Liberty Pumps X8 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Pumpe Liberty Pumps Manualer

Pumpe Manualer

Nyeste Pumpe Manualer

Guede

Guede GTT 900.1 Manual

15 September 2025
Guede

Guede GMP 7.21 Manual

15 September 2025
Ubbink

Ubbink Xtra Manual

12 September 2025
Hilti

Hilti NUN 10K-22 Manual

12 September 2025
T.I.P.

T.I.P. Dio 85/10 Flex Manual

9 September 2025
T.I.P.

T.I.P. GP 6000 INOX Manual

8 September 2025
T.I.P.

T.I.P. Garten Jet 750 Manual

8 September 2025
T.I.P.

T.I.P. GP 4000 INOX Manual

8 September 2025