Læs gratis den danske manual til Mean Well APV-12-12 (6 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 23 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 12 anmeldelser. Har du et spørgsmål om Mean Well APV-12-12, eller vil du spørge andre brugere om produktet?

Side 1/6
12W Single Output Switching Power Supply APV-12 series
Model: APV-12-12 Test Report 1 / 6
MODEL
APV-12-12
OUTPUT FUNCTION TEST
NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT
1 RIPPLE & NOISE V1: 120 mVp-p (Max ) I/P: 230 VAC
O/P:FULL LOAD
Ta:25
V1: 16 mVp-p (Max )
PASS
2 OUTPUT VOLTAGE
TOLERANCE
V1: -5 %~ +5 % (Max)
I/P: 100VAC / 264 VAC
O/P:FULL/ 0% LOAD
Ta:25
V1: -0.933%~ 1.133 %
PASS
3 LINE REGULATION V1: -1 %~ +1 % (Max)
I/P: 100 VAC ~ 264VAC
O/P:FULL LOAD
Ta:25
V1: -0.008 %~ 0.025 %
PASS
4 LOAD REGULATION V1: -2 %~ +2 % (Max)
I/P: 230 VAC
O/P:FULL ~MIN LOAD
Ta:25
V1: -0.09 %~ 0.09 %
PASS
5 SET UP TIME
230VAC/ 1500 ms (Max)
115VAC/ 1500 ms (Max)
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25
230 VAC/ 439.98 ms
115 VAC/ 889.77 ms
PASS
6 RISE TIME 230VAC/ 30 ms (Max)
115VAC/ 30 ms (Max)
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25
230 VAC/ 19.24 ms
115 VAC/ 21.18 ms
PASS
7 HOLD TIME 230VAC/ 20 ms (Typ)
115VAC/ 15 ms (Typ)
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25
230 VAC/ 82.47 ms
115 VAC/ 17.24 ms
PASS
8 OVER/UNDERSHOOT TEST < ±5 % I/P: 230 VAC
O/P:FULL LOAD
Ta:25
TEST: ±1.317%
PASS
9 DYNAMIC LOAD V1: 1200 mVp-p I/P: 230 VAC
O/P: (1)FULL /Min LOAD
90%DUTY/1KHZ
(2)FULL /Min LOAD
50%DUTY/120HZ
Ta:25
(1) 170 mVp-p
(2) 530 mVp-p
PASS
12W Single Output Switching Power Supply
APV-12 series
Model: APV-12-12 Test Report 2 / 6
INPUT FUNCTION TEST
NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT
1 INPUT VOLTAGE RANGE 90 VAC~ 264 VAC I/P:TESTING
O/P:FULL LOAD
Ta:25
90 V~ 264 V
PASS
(1)I/P: LOW-LINE-3V= 87 V
HIGH-LINE+15%= 300 V
O/P:FULL/MIN LOAD
ON: 30 Sec . OFF: 30 Sec 10MIN
(2) I/P:230VAC
ON: 0.5 Sec . OFF: 0.5 Sec 20MIN
( AC POWER ON/OFF NO DAMAGE )
TEST:
(1) OK
(2) OK
2 INPUT FREQUENCY RANGE 47HZ ~63 HZ
NO DAMAGE OSC
I/P: 90 VAC ~264 VAC
O/P:FULL~MIN LOAD
Ta:25
TEST: OK
PASS
3 EFFICIENCY 82 % (Typ) I/P: 230 VAC
O/P:FULL LOAD
Ta:25
84.17 %
PASS
4 INPUT CURRENT 230 V/ 0.2 A (Typ)
115 V/ 0.35 A (Typ)
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25
I =0.162A/ 230VAC
I =0.238A/ 115VAC
PASS
5 INRUSH CURRENT 230 V/ 70 A
115 V/ 35 A
COLD START
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25
I =57.69 A/ 230VAC
I =26.20 A/ 115VAC
PASS
PROTECTION FUNCTION TEST
NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT
1
OVER LOAD PROTECTION Above 105%
RATED OUTPUT POWER
I/P: 264 VAC
I/P: 230 VAC
I/P: 100 VAC
O/P:TESTING
Ta:25
143 %/264VAC
140 %/ 230VAC
121 %/ 100 VAC
Hiccup Mode
PASS
2
OVER VOLTAGE PROTECTION CH1: 13.8 V~ 16 V I/P: 264 VAC
I/P: 230 VAC
I/P: 90 VAC
O/P:MIN LOAD
Ta:25
14.72 V/264VAC
14.78 V/ 230VAC
14.64 V/ 90VAC
Shut off O/P voltage, clamping by
zener diode
PASS
3 SHORT PROTECTION SHORT EVERY OUTPUT
1 HOUR NO DAMAGE
I/P: 264 VAC
O/P: FULL LOAD
Ta:25
NO DAMAGE
Hiccup Mode
PASS


Produkt Specifikationer