Læs gratis den danske manual til Mean Well LPS-100-3.3 (3 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 14 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 7.5 anmeldelser. Har du et spørgsmål om Mean Well LPS-100-3.3, eller vil du spørge andre brugere om produktet?

Side 1/3
Quality Engineering Test Report
SERIES: LPS-100 100.8 WATTS SIGLE OUTPUT SWITCHING POWER SUPPLY
SAMPLE: A.LPS-100-3.3 3.3V / 20A D.LPS-100-12 12V /8.4A G.LPS-100-24 24V / 4.2A
B.LPS-100-5 5V / 20A E.LPS-100-13.5 13.5V /7.5 A H.LPS-100-27 27V / 3.8A
C.LPS-100-7.5 7.5V / 13.3A F.LPS-100-15 15V / 6.7A I. LPS-100-48 48V / 2.1A
NO TEST ITEM TEST CONDITION / SPECIFICATION RESULT VERDICT
1
A
C INPUT VOLTAGE
RANGE
I/P:TESTING SPEC:88~132V 176~264V
O/P:FULL LOAD A : 129V~267VAC P
2LINE REGULATION
I/P:176~264VAC SPEC:
O/P:FULL LOAD A: ±0.5%
B: ±0.5%
C:
±0.5%
D:
±0.5%
E: ±0.5%
F: ±0.5%
G:
±0.5%
H:
±0.5%
I : ±0.5%
A: +0.00% ~ +0.00%
B: +0.00% ~ +0.00%
C: -0.08% ~ +0.00%
D: +0.00% ~ +0.00%
E: +0.09% ~ -0.06%
F: -0.00% ~ +0.04%
G: -0.05% ~ +0.03%
H: -0.04% ~ +0.11%
I : -0.02% ~ +0.06%
P
3LOAD REGULATION
I/P:230VAC SPEC:
O/P:0% LOAD
TO FULL LOAD
A: ±2%
B: ±2%
C: ±1.5%
D: ±1.5%
E: ±1.5%
F: ±1.5%
G: ±0.5%
H: ±0.5%
I : ±0.5%
A: -0.18% ~ +0.18%
B: -0.35% ~ +0.25%
C: -0.33% ~ +0.41%
D: -0.10% ~ +0.10%
E: -0.04% ~ +0.04%
F: -0.12% ~ +0.21%
G: -0.03% ~ +0.15%
H: -0.15% ~ +0.15%
I : -0.06% ~ +0.11%
P
4OUTPUT VOLTAGE
TOLERANCE
I/P:176~264VAC SPEC:
O/P: 20% LOAD
TO FULL LOAD
A: ±3%
B: ±3%
C: ±2%
D: ±2%
E: ±2%
F: ±2%
G: ±1%
H: ±1%
I : ±1%
A: +0.00% ~ +0.36%
B: -0.76% ~ +0.00%
C: -0.59% ~ +0.08%
D: -0.10% ~ +0.05%
E: +0.00% ~ -0.13%
F: -0.33% ~ +0.00%
G: -0.13% ~ +0.10%
H: -0.02% ~ +0.39%
I : -0.19% ~ +0.03%
P
5RIPPLE&NOISE
I/P:230VAC SPEC:
O/P: FULL LOAD A:150mV
B:100mV
C:100mV
D:100mV
E:100mV
F:100mV
G:150mV
H:150mV
I :200mV
A: 26mV
B: 73mV
C: 43mV
D: 28mV
E: 21mV
F: 37mV
G: 28mV
H: 22mV
I : 23mV
P
6
A
C INPUT CURRENT
I/P:230VAC SPEC: 1.5A
O/P:FULL LOAD D:1.1A P
7MAX. INRUSH CURRENT
I/P:230VAC SPEC: 60A
O/P:FULL LOAD D:38A P
NO TEST ITEM TEST CONDITION / SPECIFICATION RESULT VERDICT
8O/P VOLTAGE
A
DJ.RANGE
I/P:230VAC SPEC: -5%~+10%
O/P:MIN. LOAD A:3.0V~3.6V
B:4.5V~5.7V
C:6V~9V
D:10V~13.2V
E:12V~15V
F:13.5V~18V
G:20V~26.4V
H:26V~32V
I:41V~56V
A:2.76V~4.04V
B:4.44V~6.25V
C:5.92V~9.28V
D:9.10V~13.70V
E:11.36V~16.12V
F:12.81V~17.00V
G:20.2V~27.6V
H:24.4V~32.6V
I :37.5V~59.4V
P
9SET UP TIME I/P:230VAC SPEC:800ms
O/P:FULL LOAD D : 580mS P
10 HOLD UP TIME I/P:230VAC SPEC:20mS
O/P:FULL LOAD D : 47mS P
11 EFFICIENCY
I/P:230VAC SPEC:
O/P: FULL LOAD A: 69%
B:77%
C:77%
D:79%
E:79%
F: 80%
G:80%
H:81%
I :81%
A: 71.91%
B: 77.64%
C: 78.99%
D: 79.40%
E: 80.22%
F: 81.03%
G: 83.37%
H: 82.70%
I : 81.87%
P
12 OVER LOAD
PROTECTION
I/P:230VAC SPEC:105%~140%
O/P:TESTING
A: 120%
B: 120%
C: 112.52%
D: 128%
E: 125%
F: 113.96%
G: 119.28%
H: 128%
I : 123.8%
P
13 OVER VOLTAGE
PROTECTION
I/P:230VAC SPEC: 110%~135%
O/P: TESTING A:3.8~4.45V
B:5.75~6.75V
C:9.4V~10.9
D:13.8V~16.2V
E:15.5V~18.2V
F:18V~21V
G:27.6V~32.4V
H:33.7V~39.2V
I:57.6V~67.2V
A: 4.17V
B: 6.30V
C: 9.29V
D: 15.14V
E: 17.31V
F: 17.01V
G: 28.2V
H: 38.0V
I : 59.5V
p
14 GROUND LEAKAGE
CURRENT
I/P:240VAC SPEC:
L-FG--<1mA
N-FG--<1mA
D: L-FG:0.75mA
N-FG:0.60mA p
15 INSULATION
RESISTANCE
SPEC: O/P-FG 500VDC / 100M Ohms MIN.
I/P-O/P 500VDC / 100M Ohms MIN.
I/P-FG 500VDC / 100M Ohms MIN.
D: O/P-FG >100M Ohms
I/P-O/P >100M Ohms
I/P-FG >100M Ohms
P
16
DIELECTRIC /
WITHSTAND
VOLTAGE
SPEC: I/P- O/P: 3000VAC/ 1 sec
(10mA CUT-OFF)
I/P - FG: 1500VAC/ 1 sec
(10mA CUT-OFF)
O/P - FG : 500VAC/1sec
(10mA CUT-OFF)
D: I/P-O/P :4.84mA
I/P-FG :3.79mA
O/P- FG :8.76mA
P
17 BURN-IN TEST I/P: 230VAC O/P:FULL LOAD
TA:27.2ºC BURN-IN DURATION : 2.0 hrs D: NON BREAK P