Læs gratis den danske manual til Mercury Grand Marquis (1997) (6 sider) i kategorien var. Denne vejledning er vurderet som hjælpsom af 8 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 4.5 anmeldelser. Har du et spørgsmål om Mercury Grand Marquis (1997), eller vil du spørge andre brugere om produktet?

Side 1/6
Universal switch insert 1gang/ Universal switch insert 2gang
Page 1/6
6W-5833D 08-2013
Universal switch insert 1gang/
Universal switch insert 2gang
Order no.: 8512 11 0x, 8512 22 0x
Operating instructions
1. Safety instructions
Electrical equipment may only be installed and assembled by a qualied electrician in
accordance with the relevant installation standards, guidelines, regulations, directives,
safety and accident prevention regulations of the country.
Failure to comply with these instructions may result in damage to the device, re or other
hazards.
Hazard due to electric shock. Do not operate device without application module.
Hazard due to electric shock. The device is not suited for safe disconnection of the
mains supply. Even when the device is switched off, the load is not galvanically separa-
ted from the mains supply.
Do not connect any non-dimmable lamps, their transformers or operating devices.
Observe manufacturer's data.
Hazard of re. During operation with conventional transformers, fuse each transformer
on the primary side according to manufacturer's data. Use safety transformers that com-
ply with EN 61558-2-6 (VDE 0570 Part 2-6) only.
These instructions are an integral component of the product and must be retained by the
end user.
2. Design and layout of the device
(3)
(1)
(4)
(7)
(6)
(8)
Figure 1: Universal switch insert 1gang
Universal switch insert 1gang/Universal switch insert 2gang
Page 2/6
6W-5833D 08-2013
(3)
(7)
(6)
(8)
(2)
(5)
Figure 2: Universal switch insert 2gang
(1) Universal switch insert
(2) Universal switch insert 2gang
(3) Frames
(4) Application module
(5) Application module 2gang
(6) Screw for dismantling protection (not R.1/R.3)
(7) Button design cover
(8) Connecting terminals
3. Function
Correct use
Only suitable for use in indoor areas with no drip and no spray water.
Switching of incandescent lamps, HV halogen lamps, dimmable energy-saving and 230 V
retrot LED lamps; electronic and dual-mode transformers or conventional transformers
with low voltage halogen lamps
Suitable for mixed loads up to the specied total capacity (see "Technical Data")
Installation into wall box according to DIN 49073 (recommended for touch switch insert
2gang, deep box)
Operate with suitable aplication module (see "Accessories")
No mixed load operation of capacitive and inductive loads possible at the output.
Product characteristics
Power extension via universal power boosters (except for switch insert 2gang, see
catalogue)
automatic setting of load-dependent switching principle and additional, optional settings via
the application module e.g. for energy-saving lamps and 230 V retrot LED lamps
Soft start for bulb protection
Electronic short circuit protection
Electronic overload and overheating protection
Electronic interference signal suppression e.g. for ripple control impulses (tariff signals)
Connection of extension unit push-button (NO contact)