Milwaukee M12 2579-20 Manual


Læs gratis den danske manual til Milwaukee M12 2579-20 (9 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.1 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Milwaukee M12 2579-20, eller vil du spørge andre brugere om produktet?

Side 1/9
Cat. No. / No de cat.
2579-20
M12 STICK TRANSFER PUMP
POMPE DE TRANSFERT SANS FIL M12
BOMBA DE TRANSFERENCIA SIN CABLES M12
OPERATOR'S MANUAL
MANUEL de L'UTILISATEUR
MANUAL del OPERADOR
WARNING To reduce the risk of injury, user must read and understand operator's manual.
comprendre le manuel.
ADVERTENCIA Para reducir el riesgo de lesiones, el usuario debe leer y entender el manual.
WARNING To reduce the risk of injury, user must read and understand operator's manual.
comprendre le manuel.
ADVERTENCIA Para reducir el riesgo de lesiones, el usuario debe leer y entender el manual.
2
GENERAL PUMP SAFETY
WARNINGS
WARNING
Read all safety warnings, instruc-
tions, illustrations and specica-
tions provided with this pump. Failure to follow all
instructions listed below may result in electric shock,
re and/or serious injury. Save all warnings and
instructions for future reference.
WORK AREA SAFETY
Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
Do not operate pump in explosive atmospheres,
such as in the presence of ammable liquids,
gases or dust.
Keep children and bystanders away while
operating a pump. Distractions can cause you to
lose control.
PERSONAL SAFETY
Stay alert, watch what you are doing and use
common sense when operating pump. Do not
use pump while you are tired or under the inu-
ence of drugs, alcohol or medication. A moment
of inattention while operating may result in serious
personal injury.
Use personal protective equipment. Always
wear eye protection. Protective equipment such
as a dust mask, non-skid safety shoes, hard hat or
hearing protection used for appropriate conditions
will reduce personal injuries.
Prevent unintentional starting. Ensure the switch
is in the o󰀨-position before connecting to power
source and/or battery pack, picking up or carrying
the pump. Carrying pumps with your nger on the
switch or energizing pumps that have the switch on
invites accidents.
Do not overreach. Keep proper footing and
balance at all times. This enables better control
of the pump in unexpected situations.
Dress properly. Do not wear loose clothing or
jewelry. Keep your hair and clothing away from
moving parts. Loose clothes, jewelry or long hair
can be caught in moving parts.
Do not let familiarity gained from frequent use
of pump allow you to become complacent and
ignore pump safety principles. A careless action
can cause severe injury within a fraction of a second.
PUMP USE AND CARE
Do not force the pump. Use the correct pump for
your application. The correct pump will do the job
better and safer at the rate for which it was designed.
Do not use the pump if the switch does not turn
it on and o󰀨. Any pump that cannot be controlled
with the switch is dangerous and must be repaired.
Remove the battery pack from the pump before
making any adjustments, changing accessories,
or storing. Such preventive safety measures reduce
the risk of starting the pump accidentally.
Store idle pump out of the reach of children and
do not allow persons unfamiliar with the pump or
these instructions to operate the pump. Pumps
are dangerous in the hands of untrained users.
Maintain pump and accessories. Check for mis-
alignment or binding of moving parts, breakage
of parts and any other condition that may a󰀨ect
the pumps operation. If damaged, have the pump
repaired before use. Many accidents are caused
by poorly maintained pumps.
Use the pump, accessories and etc. in accordance
with these instructions, taking into account the
working conditions and the work to be performed.
Use of the pump for operations di󰀨erent from those
intended could result in a hazardous situation.
Keep handles and grasping surfaces dry, clean
and free from oil and grease. Slippery handles and
grasping surfaces do not allow for safe handling and
control of the pump in unexpected situations.
BATTERY USE AND CARE
Recharge only with the charger specied by the
manufacturer. A charger that is suitable for one type
of battery pack may create a risk of re when used
with another battery pack.
Use pump only with specically designated
battery packs. Use of any other battery packs may
create a risk of injury and re.
When battery pack is not in use, keep it away
from other metal objects, like paper clips, coins,
keys, nails, screws or other small metal objects,
that can make a connection from one terminal
to another. Shorting the battery terminals together
may cause burns or a re.
Under abusive conditions, liquid may be ejected
from the battery; avoid contact. If contact ac-
cidentally occurs, flush with water. If liquid
contacts eyes, additionally seek medical help.
Liquid ejected from the battery may cause irritation
or burns.
Do not use a battery pack or pump that is dam-
aged or modied. Damaged or modied batteries
may exhibit unpredictable behavior resulting in re,
explosion or risk of injury.
Do not expose a battery pack or pump to re
or excessive temperature. Exposure to re or
temperature above 265°F (130°C) may cause
explosion.
Follow all charging instructions and do not
charge the battery pack or pump outside the
temperature range specied in the instructions.
Charging improperly or at temperatures outside the
specied range may damage the battery and increase
the risk of re.
SERVICE
Have your pump serviced by a qualied repair
person using only identical replacement parts.
This will ensure that the safety of the pump is
maintained.
Never service damaged battery packs. Service
of battery packs should only be performed by the
manufacturer or authorized service providers.
SPECIFIC SAFETY RULES FOR
PUMPS
CAUTION
This pump has been evaluated for
use with water only.
-Do NOT use in a ammable or explosive atmo
sphere. Do NOT pump brine, laundry discharge,
or any other application which may contain
caustic chemicals and/or foreign material. Do
NOT pump uids such as gasoline, fuel oil, or
kerosene.
WATER ONLY - Do not pump gasoline or other
ammable liquids.
Not for potable water.
Acceptable for indoor or outdoor use.
Do not submerge handle or battery.


Produkt Specifikationer

Mærke: Milwaukee
Kategori: Ikke kategoriseret
Model: M12 2579-20

Har du brug for hjælp?

Hvis du har brug for hjælp til Milwaukee M12 2579-20 stil et spørgsmål nedenfor, og andre brugere vil svare dig