Mirage 59652 Manual

Mirage Komfur 59652

Læs gratis den danske manual til Mirage 59652 (12 sider) i kategorien Komfur. Denne vejledning er vurderet som hjælpsom af 4 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 2.5 anmeldelser. Har du et spørgsmål om Mirage 59652, eller vil du spørge andre brugere om produktet?

Side 1/12
Operator’s Manual
Mirage
®
Countertop and Drop-in Induction Ranges
©
2020 The Vollrath Company L.L.C. Part No. 351044-1 ml 1/10/20
Thank you for purchasing this Vollrath equipment. Before operating the
equipment, read and familiarize yourself with the following operating
and safety instructions. SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE. Save the original box and packaging. Use this packaging
to ship the equipment if repairs are needed.
SAFETY PRECAUTIONS
To ensure safe operation, read the following statements and understand
their meaning. This manual contains safety precautions which are
explained below. Please read carefully.
Warning is used to indicate the presence of a hazard that will or can
cause severe personal injury or death.
Caution is used to indicate the presence of a hazard that will or can
cause minor or major personal injury if the caution is ignored.
NOTICE: Notice is used to note information that is important but not
hazard-related.
To reduce risk of injury or damage to the equipment:
Plug only into grounded electrical outlets that match the voltage on
the rating label.
This equipment requires a dedicated circuit.
Do not use extension cords, power strips or surge protectors with
this equipment.
Unplug this equipment from the wall outlet when not in use.
Use this equipment only in a flat, level position.
To protect against electrical shock do not immerse the cord or plug
in water. Keep the cord away from heated surface. Do not let the
cord hang over the edge of table or counter.
As a precaution, persons using a pacemaker should stand back 12"
(30 cm) from an operating unit. Studies have shown that the
induction element will not disrupt a pacemaker.
Keep all credit cards, driver licenses and other items with a magnetic
strip away from an operating unit. The unit’s magnetic field will
damage the information on these strips.
The heating surface is made of a strong, non-porous material.
However, should it crack or break, stop using and immediately
unplug the unit. Cleaning solutions and spills could penetrate the
broken cook-top and create a risk of electrical shock.
Do not operate this equipment with a damaged cord or plug or if it is
not functioning properly.
Do not operate unattended. Closely supervise units operating in
public areas and/or around children.
Do not place any objects inside the air intake or exhaust panels.
Do not attach any accessory objects to this equipment.
FUNCTION AND PURPOSE
This equipment is intended for use in commercial food service
operations only. It is not intended for household, industrial or
laboratory use. It is intended to be used with induction-ready cookware.
WARNING
CAUTION
Item No. Description
Plug
59500
Mirage
®
Countertop Induction Range, US
NEMA 5-15P
59510
Mirage
®
Countertop Induction Range,
US, Canada
59650
Mirage
®
Countertop Induction Range
Schuko
59651 UK
59652 China
59655 AU
59501
Mirage
®
Drop-in Induction Range
NEMA 5-15P
59601 Schuko
59602 UK
59603 China
59605 AU
2 Mirage
®
Countertop and Drop-in Induction Ranges Operator’s Manual
COOKWARE REQUIREMENTS
Note: Cookware with inferior construction or material may not perform
well. Cookware with a larger base diameter can be used, however only
the area of the cookware above the induction coil will heat. The more
cookware extends past the coil, the more the overall performance will
be reduced.
FCC STATEMENT
This equipment has been tested and found to comply with Part 18 of
FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
To assure continued compliance, any changes or modifications not
expressly approved by the party Responsible for compliance could void
the user’s authority to operate this equipment.
COUNTERTOP RANGE INSTALLATION
Clearance and Environment Requirements
NOTICE: This unit is not designed to be enclosed or built into any
area. Sufficient airflow must be allowed around the unit.
Blocking the airflow could cause the unit to overheat.
Rear of the range to any surrounding surface: 4" (10 cm)
Bottom of the range to any surrounding surface: ¹⁄₂"(2cm)
Indoor use only.
Do not place the equipment on or near heat-producing equipment.
Installation
1. Place the induction range/warmer on a flat stable surface.
2. Plug the power cord into a grounded electrical outlets that match the
voltage on the rating label.
NOTICE: This equipment requires a dedicated circuit.
NOTICE: Using a voltage other than the nameplate rated voltage
will cause damage to the unit. Incorrect voltage,
modification to the power cord or electrical components
can damage unit and will void the warranty.
DROP-IN RANGE INSTALLATION
Before you begin
1. Download the specification sheet for your drop-in from
Vollrath.com. You will need to refer to this document for
dimensions, clearance, venting and power requirements.
2. Verify the proper electrical outlet is available at the installation site.
NOTICE: This equipment requires a dedicated circuit.
NOTICE: Do NOT modify the cord or plug on the drop-in. Modifying
any component may damage the drop-in or cause injury,
and will void the warranty. See the specification sheet on
Vollrath.com for electrical specifications.
3. Know the countertop manufacturer's requirements for preparing and
installing equipment into the countertop prior to starting installation.
Prepare the Countertop and Cabinet
NOTICE: Refer to the drop-in specification sheet for cutout
dimensions, air flow and venting requirements, minimum
clearance distances and environment requirements.
NOTICE: Countertop materials require specific preparation. Refer to
the countertop manufacturer for instructions regarding
proper installation of equipment into the material.
NOTICE: Exposed wood or particle board edges must be sealed with
an appropriate waterproofing material. Seal the edge
between the glass and the countertop with silicone or
similar material. Failure to do so may result in damage to
the countertop.
1. Cut required openings in the countertop and cabinet.
2. Clean debris from the cut out area(s).
3. Reinforce the countertop support as needed per the countertop
manufacturer guidelines and the weight of the equipment.
Mount the Drop-in
1. Choose a flat, level countertop for the mounting surface.
2. Measure the area for the cutout, including the countersink area. The
unit is designed to be countersunk. The depth of the surface around
the cutout must be reduced to allow for the countersink. See the
specification sheet.
Compatible
Drop-in Ranges: Flat base
4¾" to 12" (12.1 to 30.5 cm) in
diameter
Countertop Ranges: Flat base
4¾" to 10¼" (12.1 to 26.0 cm)
in diameter
Ferrous stainless steel, iron,
cast iron
Incompatible
Base is not flat
Base is less than 4¾" (12.1 cm)
in diameter
Pottery, glass, aluminum,
bronze or copper cookware
Metal disk on bottom of pan
NOTICE: Equipment Damage Hazard
Not intended for use with aluminum pans with a metal disk
on the bottom. Under high heat, the metal disk will separate
from the pan. These pans may damage your unit and void
your warranty.
less than 4¾"
mirage


Produkt Specifikationer

Mærke: Mirage
Kategori: Komfur
Model: 59652

Har du brug for hjælp?

Hvis du har brug for hjælp til Mirage 59652 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Komfur Mirage Manualer

Mirage

Mirage 59510P Manual

2 Oktober 2025
Mirage

Mirage 59601 Manual

1 Oktober 2025
Mirage

Mirage 59508DW Manual

1 Oktober 2025
Mirage

Mirage 59300 Manual

1 Oktober 2025
Mirage

Mirage 59508DW02 Manual

1 Oktober 2025
Mirage

Mirage 59651 Manual

1 Oktober 2025
Mirage

Mirage 59508DW04 Manual

1 Oktober 2025
Mirage

Mirage 59652 Manual

1 Oktober 2025
Mirage

Mirage 59500P Manual

1 Oktober 2025
Mirage

Mirage 59502DW Manual

1 Oktober 2025

Komfur Manualer

Nyeste Komfur Manualer

Consul

Consul CFS50A Manual

2 Oktober 2025
Consul

Consul CFC50D Manual

2 Oktober 2025
Respekta

Respekta SH1000-33 Manual

2 Oktober 2025
Airlux

Airlux ATIF64BKM Manual

2 Oktober 2025
ElectriQ

ElectriQ IQGH603S Manual

2 Oktober 2025
Airlux

Airlux TI83H Manual

2 Oktober 2025
Airlux

Airlux AT32K01 Manual

2 Oktober 2025
Airlux

Airlux ATIN4BK Manual

2 Oktober 2025