Læs gratis den danske manual til Moxa ioLogik R1214-T (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 22 personer og har en gennemsnitlig bedømmelse på 3.5 stjerner ud af 11.5 anmeldelser. Har du et spørgsmål om Moxa ioLogik R1214-T, eller vil du spørge andre brugere om produktet?

Side 1/2
1 2 3
P/N: 1802012002011
ioLogik R1200 Series
Quick Installation Guide
Second Edition, April 5 201
Overview
The ioLogik R1200 comes with 2 RS-485 serial ports, which can be
used in one of two ways:
1. For backup or asset monitoring, or
2. As an RS-485 repeater.
The ioLogik R1200 has the industry’s first all- -one design and in
provides Automatic Field Configuration via USB. No technical
background is needed, and maintenance is easy since users can
upload a device’s configuration settings and firmware via USB,
without needing to take a PC to the field site.
Model Selection:
ioLogik
DI
DIO
Relay
AI
AO
R1210
16
R1212
8
8
R1214
6
6
R1240
8
R1241
4
Package Checklist
1 ioLogik R1200 series remote I/O product
Documentation and software CD
Quick installation guide (printed)
Specifications
System
Serial IO
2 x -485-2W: Data+, Data-, GND RS
(5-contact terminal block)
Protection
8 KV ESD, 1 KV surge, 3 KV EFT
Protocols
Modbus/RTU
Power Input
24 VDC nominal, 12 to 48 VDC
Wiring
I/O cable max. 14 AWG
Dimensions
27.8 x 124 x 84 mm (1.09 x 4.88 x 3.31 in)
Weight
under 200 g
Operating Temperature
Standard Models: -10 to 75°C (14 to
167°F)
Wide Temperature Models: -40 to 85°C
(-40 to 185°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
5 to 95% (non-condensing)
Up to 2000 m
Note: Please contact Moxa if you require products guaranteed to
function properly at higher altitudes.
UL 508, CE, FCC Class A
5 years (excluding ioLogik R1214*)
See www.moxa.com/warranty
*Because of the limited lifetime of power relay, products that use
this component are covered by a 2-year warranty.
Communication Parameters (Initial mode)
Parity
None, Even, Odd (default = None)
Data Bits
8
Stop Bits
1 2 (default = 1),
Flow Control
None, XON/XOFF (default = None)
Baudrate
1200 to 921.6 kbps (default = 9600)
Digital Input
NPN, PNP, and Dry contact
DI or Event Counter
On: short to GND
Off: open
On: 10 to 30 VDC
Off: 0 to 3 VDC
3K VDC or 2K Vrms
2.5 kHz, power off storage
Digital Output
DO or Pulse Output
0.1 ms / 5 kHz
45 VDC
2.6 A (4 channels @650 mA)
175°C (typical), 150°C (min.)
200 mA per channel
3K VDC or 2K Vrms
Relay Output
Form A (N.O.) relay outputs, 5A
5 A @ 30 VDC, 5 A @ 250 VAC, 5 A @ 110
VAC
2 A
5 A
500 VAC
1500 ms (Max.)
1G min. @ 500 VDC
Expected Life
100,000 times (Typical)
Initial Contact
Resistance
30 milli-ohms (Max.)
Pulse Output
0.3 Hz at rated load
Analog Input
Type
Differential input
Resolution
16 bits
I/O Mode
Voltage / Current
Input Range
0 to 10 VDC, 4 to 20 mA
Accuracy
± 0.1% FSR @ 25°C
± 0.3% FSR @ -10 and 60°C
± 0.5% FSR @ -40 and 75°C
Sampling Rate (all
channels)
12 samples/sec
Input Impedance
10M ohms (minimum)
Built-in Resistor for
Current Input
120 ohms
Analog Output
Resolution
12 bits
Output Range
0 to 10 VDC, 4 to 20 mA
Voltage Output
10 mA (Max.)
Accuracy
± 0.1% FSR @ 25°C
± 0.3% FSR @ -40 and 75°C
Load Resistor
• Internal power: 400 ohms
• External 24V power: 1000 ohms
Installation
Power and Networking
Connect the +12 to +48 VDC power line to the ioLogik R1200’s
terminal block terminal; connect the ground from the power V+
supply to the V- terminal. Connect the ground pin ( ) if earth
ground is available.
NOTE
For safety reasons, the wires attached to the power should
be at least 2 mm (12 gauge) in diameter.
4 5 6
www.moxa.com/support
The Americas:
- -528-6777 (toll-free: 1-888- - +1 714 669 2872)
Europe:
+49- -3 70 03 99-0 89
Asia-Pacific:
+886-2-8919- 1230
China:
+86- -5258-9955 (toll-free: 800- -5036) 21 820
5 Moxa Inc. All Rights Reserved 201 ,
Switch Settings
The R1200 series provides Dual/Rep and Run/Initial switch
setting to set up the communication mode. s
Duel (Default)
Dual RS-485 mode
Rep
Repeater mode
Run
User define communication parameters
Initial (Default)
Initial RS-485 communication parameters
Jumper Settings
The models with DIO or AI channels require configuring the
jumpers inside the enclosure. Remove the screw located on the
back panel and open the cover to configure the jumpers.
DIO mode configuration is
shown to the right (default: DO
Mode).
Analog mode configuration is
shown to the right (default:
Voltage Mode).
Mounting
The ioLogik R1200 is designed with a vertical form factor, and can
be used with both DIN-Rail and wall mounting applications. When
mounting on a rail, release the bottom mounting kit, install the
ioLogik on the rail, and then restore the bottom mounting kit to fix
the ioLogik to the rail. When using wall mounting, release both the
upper and bottom DIN-Rail kits.
LED Indicators
Type
LED Color
LED Action
PWR
Green
On:
Power On
Off:
Power Off
RDY
Green/
Red
Green:
System Ready
Green
Blinking:
Located
Red:
System Boot-up Error
Red
Blinking:
Firmware upgrade / USB upgrade
Green/Red
Blinking:
Safe Mode
Off:
System NOT Ready
P1
Green/
Amber
Green:
Tx
Amber:
Rx
Blinking:
Data Transmitting
Off:
Disconnected
P2
Green/
Amber
Green:
Tx
Amber:
Rx
Blinking:
Data Transmitting
Off:
Disconnected
I/O Wiring
Digital Input/Output (Sink Type)
Analog Input
Relay Output (Form A)
System Configuration
ioSearch Utility
ioSearch is a search utility that helps users locate an ioLogik R1200
on the local network. The utility can be found in the Document and
Software CD Software ioSearch; the latest version can be  
downloaded from Moxa website. ’s
Load Factory Default Settings
There are three ways to restore the ioLogik R1200 to the factory
default settings.
1. Hold the RESET button for 5 seconds.
2. Right click the specified ioLogik in the ioSearch utility and
select Reset to Default “ .”
3. Select Load Factory Default from the web console. “ ”
Modbus Address Table
Please refer to the user s manual for details of the ioLogik’ ’s
Modbus address.
NOTE
A “load” in a circuit schematic is a component or portion of
the circuit that consumes electric power. For the diagrams
shown in this document, “load” refers to the devices or
systems connected to the remote I/O unit.


Produkt Specifikationer

Mærke: Moxa
Kategori: Ikke kategoriseret
Model: ioLogik R1214-T
Strøm: 0.207 A
Dimensioner (BxDxH): 27.8 x 124 x 84 mm
Antal kanaler: 6 kanaler
Seriel grænsefladetype: RS-485
Relativ luftfugtighed: 5 - 95 %
Signalretning: Indgang/udgang
Indgangsspændingsområde: 12 - 48 V

Har du brug for hjælp?

Hvis du har brug for hjælp til Moxa ioLogik R1214-T stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Moxa Manualer

Moxa

Moxa OnCell G3150 Manual

23 August 2024
Moxa

Moxa M-3411 Manual

23 August 2024
Moxa

Moxa M-1600 Manual

23 August 2024
Moxa

Moxa TCC-82-RP Manual

23 August 2024
Moxa

Moxa UPort 1410 Manual

23 August 2024
Moxa

Moxa M-1450 Manual

23 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer