Oreck Elevate Control UK30100PC Manual

Oreck Støvsuger Elevate Control UK30100PC

Læs gratis den danske manual til Oreck Elevate Control UK30100PC (8 sider) i kategorien Støvsuger. Denne vejledning er vurderet som hjælpsom af 27 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 14 anmeldelser. Har du et spørgsmål om Oreck Elevate Control UK30100PC, eller vil du spørge andre brugere om produktet?

Side 1/8
©2021 Techtronic Floor Care Technology Limited. All Rights Reserved. Distributed by, Royal Appliance Mfg. Co. Charlotte, NC 28262. 964A00253-R1
Please visit Oreck.com for video instructions and
FAQ’s for this Carpet Cleaner.
For assistance, please call Customer Service:
1-800-989-3535 Mon-Fri: 9:00am - 6:00pm EST.
Sat-Sun: Closed
Replacement parts and accessories such
as bags available at Oreck.com.
CAUTION
:
TO REDUCE THE RISK OF DAMAGE:
Avoid picking up hard, sharp objects with this product, as they may cause damage.
Store appropriately indoors in a dry place. Do not expose machine to freezing
temperatures.
Brushroll continues to rotate while product is turned on and handle is in the upright
position. To avoid damage to carpet, rugs and ooring, avoid tipping vacuum or
setting it on furniture, fringed area rugs or carpeted stairs.
With brushroll on, do not allow cleaner to sit in one location for an extended period of
time, as damage to floor can result.
WARNING:
To reduce the risk of electric shock, this vacuum has a polarized plug
(one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the
plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified
electrician to install the proper outlet. Do not change the plug in any way.
Any other servicing should be done by an authorized service representative. Call
1-800-989-3535 for the nearest service center or visit our website at www.Oreck.com.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
READ ALL SAFETY WARNINGS AND INSTRUCTIONS BEFORE USING THIS PRODUCT.
WARNING:
When using an electrical product, basic precautions should
always be to avoid electric shock, fire, and/or serious injury, followed
including the following:
Fully assemble or install product prior to use.
Do not plug in or use until fully assembled.
Operate vacuum only at voltage specified on data plate on bottom of cleaner.
Do not leave vacuum when plugged in. Unplug from outlet when not in use and before
cleaning or servicing.
Do not use outdoors or on wet surfaces.
Do not allow to be used as a toy. Not intended for use by children age 12 and under.
Close supervision is necessary when used by or near children. To avoid injury or
damage, keep children away from product, and do not allow children to place ngers or
other objects into any openings.
Use only as described in this manual. Use only manufacturer’s recommended
attachments and products
Do not use with damaged power cord or plug. If vacuum is not working as it should, has
been dropped, damaged, left outdoors, or dropped into water, have the product
inspected by an Authorized Oreck® Service Center prior to continuing use. Call
1-800-989-3535 for the nearest service center or visit our website at www.Oreck.com.
Do not pull or carry by power cord, use cord as handle, close a door on cord, or pull cord
around sharp edges or corners. Do not run vacuum over cord. Keep cord away from
heated surfaces.
Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
Do not handle plug or vacuum with wet hands.
Do not put any objects into openings. Do not use with any opening blocked; keep free of
dust, lint, hair, and anything that may reduce air ow.
Keep hair, loose clothing, ngers, and all parts of body away from openings and moving
parts. Brushroll continues to operate when in the upright position.
Turn o all controls before unplugging.
Use extra care when cleaning on stairs. To avoid personal injury or damage, and to
prevent the cleaner from falling, always place cleaner at bottom of stairs or on floor.
Do not place cleaner on stairs or furniture, as it may result in injury or damage.
Do not use to pick up flammable or combustible liquids, such as gasoline, or fine wood
sandings or use in areas where they may be present.
Do not pick up anything that is burning or smoking, such as cigarettes, matches, or
hot ashes.
Do not use without inner filtration bag in place.
UPRIGHT VACUUM
IMPORTANT: READ CAREFULLY BEFORE ASSEMBLY AND USE. This product is intended for
household use only. If used commercially or with non-Oreck
®
filtration bags and
components, warranty is void.
For assistance, please call Customer Service at 1-800-989-3535
Mon-Fri: 9:00am - 6:00pm EST.
Sat-Sun: Closed
USER MANUAL
MODELS: UK30100 / UK30100COM / UK30170
Puede encontrar la versión en español de este
manual en Oreck.com en esta página de productos.
Versión en
español:
Only certified Oreck
®
Accessories, parts and filtration bags can be used with this
vacuum. Oreck
®
cannot guarantee optimal performance with the use of unauthorized
products, thus the use of non-Oreck
®
components will void warranty.
To ensure accessories, parts and filtration bags are genuine, purchase only through a
Factory Authorized Dealer or through Oreck.com. Certified Oreck
®
filtration bags will
carry the mark below.
CERTIFIED PARTS
WARRANTY
TTI Floor Care North America (ORECK) gives you the following limited warranty for this
product only if it was originally purchased and solely used residentially, not for resale,
from Oreck or an Oreck Authorized Retail Dealer. Oreck will repair or replace, free of
charge, to the original purchaser, any part that is found to be defective in material or
workmanship within three (3) years following the date of purchase for all residential
models. NOTE: Warranty is void if used in a commercial setting. This limited warranty does
not cover the replacement of expendable or consumable parts such as filters, cartridges,
and other parts subject to normal wear unless they are defective in material or
workmanship. This limited warranty does not apply to any part subjected to accident,
abuse, commercial use, alteration, misuse, damage caused by an act of God, the use of
voltages other than on the data plate of this product or service of this product by other than
Oreck or a participating Factory Authorized Service Center. Oreck does not authorize any
person or representative to assume or grant any other warranty obligation with the sale of
this project. The Oreck limited warranty is valid only if you retain proof of purchase from
Oreck or an Oreck Authorized Retail Dealer for this product. If you purchase this product
from any other source, your purchase is “AS IS,” which means Oreck grants you no
warranty, and that you, not Oreck assume the entire risk of the quality and
performance of the product, including the entire cost of any necessary
servicing or repairs of any defects. The Oreck liability for damages to you for
any costs whatsoever arising out of this statement of limited warranty shall
be limited to the amount paid for this product at the time of original
purchase, and Oreck shall not be liable for any direct, indirect, consequential
or incidental damages arising out of the use or inability to use this product.
Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitations or exclusions may not
apply to you. ALL EXPRESS AND IMPLIED WARRANTIES OTHER THAN THE
LIMITED WARRANTY SET FORTH ABOVE, FOR THE PRODUCT, INCLUDING
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE EXPRESSLY DISCLAIMED. This warranty gives
you specific legal rights, and you may also have other rights, which vary
from state to state. Notwithstanding the foregoing, no warranty provided
herein or arising under any applicable law shall exceed 3 years in duration.
VACUUM INTRODUCTION
U
K
G
O
P
N
C
L
X
Q
T
S
A
B
E
H
J
V
D
F
R
I
W
M
Y
TECHNICAL SPECIFICATIONS
Name CurrentVoltage Wattage Cord Length Weight
UK30100 120V 4A 480W 30 ft 9 lbs
UK30100COM 480W120V 4A 30 ft 9 lbs
UK30170 120V 4A 480W 30 ft 9 lbs
Please register your product to initiate warranty, service plans and expert advice on
whole-home cleaning:
online at Oreck.com or call 1.800.989.3535 (U.S).
A. Ergonomic Handle
B. On/Off Fingertip
Controls
C. Power Cord Release
Hook
D. Upper Tube
E. Filtration Bag Port
F. Filtration Bag
G. Carry Handle
H. Security Zipper
I. Power Head
J. Protective Bumper
K. Side Edge Brushes
L. Service Door
M. LED Headlights
N. Power Cord
O. Connectivity Cord
P. Upper Tube
Connector
Q. Debris Transfer Tube
R. Filtration Bag Case
S. Lower Tube
Connectors
T. Lower Tube
U. Fan Housing
V. Case Clasp
W. Brushroll
X. Front and Rear
Wheels
Y. Debris Shield
ASSEMBLING YOUR
ELEVATE
A
B
Make sure Upper Tube Connector (A) is
installed on Upper Tube (B).
1
C
Insert Upper Tube into the top of Debris
Transfer Tube (C) until it locks in place.
2
A
B
3
Twist Upper Tube Connector (A)
clockwise until it clicks to secure Upper
Tube (B).
USING YOUR
ELEVATE
3
Place the foot on the electric brush
(A) and pull the handle backwards to
place the unit in the operating
position. Fully raise the handle to the
vertical position to engage the lock.
Do not operate the unit when locked
in the upright position.
A
Please read “Important Safety
Instructions before use.
2
Push fingertip controls on the handle
forward into the “ON” position to turn
on. Push controls backward into the
“OFF” position to turn off.
CAUTION:
Not to be used for
grooming a pet.
1
Make sure the filtration bag (A) is
attached properly to the filtration
bag dock (B). Attachment
instructions are located on the
filtration bag and in the maintenance
section of this manual. Your vacuum
comes with a bag preinstalled for
your convenience. Do not operate
without a bag.
A
B
3
Gently pull the cardboard collar on
the filtration bag up to engage the
SaniSeal® lock and remove from the
bag dock. Discard.
CHANGING THE
FILTRATION BAG
(
CONTD
)
4
Slide a new filtration bag collar
firmly into the bag dock ensuring all
hooks on dock door are inserted on
the cardboard collar.
5
Rotate bag dock up and press firmly
on the filtration bag at indicated
points until it snaps into place.
6
Zip up the filtration bag case
completely
.
ADJUSTING OR
REPLACING
BRUSHROLL (CONT’D
ADJUSTING OR
REPLACING
BRUSHROLL
NEW
1
Your Oreck
®
unit comes with the
brushroll assembled in the “NEW
position (multiple notches showing on
top edge). As the brushroll wears it can
be adjusted for longer life.
2
Lay the unit flat to access the power
head nozzle. Remove the 7 screws to
take off the baseplate from the power
head.
3
Remove the brushroll belt and
brushroll from the holding channels
inside of the power head nozzle.
OLD
4
When worn, rotate both plastic black
endcaps at the ends of the brushroll
to show a single notch “OLD
position. Insert back into the holding
channels of the power head nozzle.
5
When rotating the black endcaps on the
brushroll, make sure both endcap
settings are the same and faceup when
you insert the brushroll.
6
Reassemble the brushroll belt.
Reference the Maintenance Section
on Checking and Replacing the
Brushroll Belt for details.
7
Manually spin the brushroll to see that
it turns freely.
1
Lay the unit flat to access the power
head nozzle. Remove the 2 screws
located on the bottom side of the
service door.
3
Remove the brushroll belt from the
(A) motor shaft and (B) brushroll
pulley.
A
B
2
Slide the service door down away from
the unit to reveal the brush roller belt
(A).
A
CHECKING AND
REPLACING
BRUSHROLL BELT
CHECKING AND
REPLACING
BRUSHROLL BELT
(CONT’D)
4
Loop the new belt over (A) brushroll
pulley. Place the opposite end of the
belt on the (B) motor shaft.
A
B
6
Replace the 2 screws and tighten.
5
Replace the service door by aligning
the screw tabs with the bottom of the
power head nozzle.
USING YOUR
ELEVATE
(
CONT’D
)
A
C
B
4
Wrap Power Cord around Power Cord
Release Hook (A) and the Carry
Handle (B) as shown for convenient
storage. Use the clip on the plug (C)
to attach the plug end to the power
cord. Raise the carry handle for easy
lifting and carrying. Lower the carry
handle during other use to eliminate
obstructions.
5
Twist the power cord release hook
to either side to quickly unwrap the
power cord for use.
CAUTION:
Very fine
materials, such as face powder or
cornstarch m ay seal the inner
filtration bag and cause it to burst
even though it is only partially full.
Chan ge the bag often when
cleanin g this type of material.
CHANGING THE
FILTRATION BAG
SANISEAL
®
OPERATION
Your Elevate
vacuum includes a filtration
bag equipped with the SaniSeal
®
System.
SaniSeal
®
automatically locks in
allergens, dirt and debris each time you
change the bag.
WARNING:
To reduce the
risk of personal injury, unplug before
cleaning or servicing. Do not use
vacuum without inner filtration bag
in place.
FILTRATION BAG PART NUMBERS
AK1CC6 - Standard, AK1CC6A -
Allergen, and AK1CC6H -HEPA
2
Pull the cardboard collar on the
filtration bag downward to release
the bag dock from the dock port
.
1
Unzip the Filtration Bag Case
completely.
IMPORTANT NOTE:
To keep your Elevate
vacuum running
at optimal performance, make sure to
change the filtration bag when the
contents reach the MAXIMUM FILL
LINE. Overloading may result in loss
of air flow suction and decreased
performance.
LUBRICATION: The motor and brushroll
are equipped with bearings which
contain sufficient lubrication for their
lifetime. The addition of lubricant
could cause damage. Do not add
lubricant to motor or brushroll.
MOTOR PROTECTIONS: If the vacuum
becomes overloaded (which could occur
when a large obstruction is sucked up or
when vacuuming extremely thick carpet),
the electronics are designed to shut down
the vacuum. If this happens, the vacuum
will automatically shut off and the
headlights will flash. To reset the vacuum,
turn the unit “off”, then turn on to continue
use. If it shuts down again there may be a
large obstruction in the vacuum. See
Clearing Blockages for the steps on
clearing a blockage.
THE BELT: This vacuum is equipped
with the Endurolife Belt, which is
designed for long life and doesn’t
need changing.
WARNING: TO REDUCE THE RISK OF
PERSONAL INJURY, UNPLUG BEFORE
CLEANING OR SERVICING.
TROUBLESHOOTING
FIND AVAILABLE REPLACEMENT PARTS AND ACCESSORIES AT ORECK.COM.
IF APPLIANCE IS NOT WORKING AS IT SHOULD, HAS BEEN DROPPED, DAMAGED, LEFT
OUTDOORS, OR DROPPED INTO WATER, CALL CUSTOMER SERVICE AT 1-800-989-
3535 PRIOR TO CONTINUING USE.
ACCESSORIES
GENUINE PARTS AND ACCESSORIES: We recommend using only with genuine
ORECK® replacement bags (for Oreck bagged uprights), parts, and accessories.
Damage caused by use with other than genuine ® bags, parts, and ORECK
accessories is not covered by and may void your warranty.
8
Replace the 7 screws to secure the
baseplate to the power head nozzle.


Produkt Specifikationer

Mærke: Oreck
Kategori: Støvsuger
Model: Elevate Control UK30100PC

Har du brug for hjælp?

Hvis du har brug for hjælp til Oreck Elevate Control UK30100PC stil et spørgsmål nedenfor, og andre brugere vil svare dig