Panasonic CZ-KPU3AW Manual


Læs nedenfor 📖 manual på dansk for Panasonic CZ-KPU3AW (4 sider) i kategorien Klimaanlæg. Denne guide var nyttig for 16 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/4
1
Operating Instructions
Panel for Cassette (ECONAVI type)
Model No. CZ-KPU3AW
Applicable indoor unit : 4-Way Cassette
Before operating the unit, read these operating instructions
thoroughly and keep them for future reference.
Thank you for purchasing this Panasonic product.
This product is a optional of commercial air conditioner
indoor unit.
Installation Instructions attached.
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
Specifi cations ....................................................................
2
Safety Precautions ............................................................
3
Precautions for Use ..........................................................
5
Names of Parts ..................................................................
6
Detection Area of Sensor (Criteria) ...............................
7
How to Operate Remote Controller
(Setting Method of Each Function) ...............................
8
ECONAVI Function .........................................................
9
• Direct Airfl ow and Indirect Airfl ow Function .............
11
Circulation Function .....................................................
12
External Device Interlock Function .............................
13
Maintenance ....................................................................
14
Troubleshooting ..............................................................
15
Contents
Product Information
If you have problems or questions concerning your Air
Conditioner, you will need the following information. Model and
serial numbers are on the nameplate.
Model No.
Serial No.
Date of purchase
Dealer’s address
Phone number
ACXF55-26550
2
Specifi cations
Model Name CZ-KPU3AW
Unit Dimensions (Width) 950mm × (Depth) 950mm × (High) 33.5mm
Net Weight 5 kg
Temperature / Humidity Range 0°C to 40°C / 20% to 80% (Indoor use only)
Power Source DC16 V (Supplied from indoor unit)
Panasonic Corporation
http://www.panasonic.com
Printed in JAPAN
© Panasonic Corporation 2019 ACXF55-26550
DC0719-0
Authorised representative in EU
Panasonic Testing Centre
Panasonic Marketing Europe GmbH
Winsbergring 15, 22525 Hamburg, Germany
3
Safety Precautions
Con rm to authorized dealer
or specialist on usage of
speci ed refrigerant type. Using
of refrigerant other than the
speci ed type may cause product
damage, burst and injury etc.
Do not use ECONAVI function
when only a disabled person
or infant staying at home. If a
small movement of human body
continues for a long time, Panel
for cassette (ECONAVI type)
recognizes human absence and
air conditioner may sometimes
stop operating.
Do not use this appliance in a
potentially explosive atmosphere.
Never touch the unit with wet
hands.
Do not insert your fi ngers or
other objects into the air
conditioner indoor or
outdoor unit, rotating parts may
cause injury.
If the refrigerant comes in contact
with a fl ame, it produces a toxic
gas.
For safety, be sure to turn the
air conditioner off and also to
disconnect the power before
cleaning or servicing.
Pull off the power plug from
a receptacle, or switch off
the breaker, or switch off
the power disconnecting mean to
isolate the air conditioner from the
main power supply in case of
emergency.
Dispose of according to national
and/or local legislation.
This product must not be modifi ed
or disassembled under any
circumstances.
Modi ed or disassembled unit
may cause fi re, electric shock or
injury.
Do not clean inside the indoor and
outdoor units by users. Engage
authorized dealer or specialist for
cleaning.
In case of malfunction of this
appliance, do not repair by yourself.
Contact the sales dealer or service
dealer for a repair and disposal.
The following symbols used in this manual, alert you to
potentially dangerous conditions to users, service personnel or
the appliance:
WARNING This symbol refers to a hazard or
unsafe practice which can result in
severe personal injury or death.
CAUTION
This symbol refers to a hazard or
unsafe practice which can result
in personal injury or product or
property damage.
Prohibited matters Matters to be
observed
Read these Operating Instructions carefully before using this
air conditioner. If you still have any diffi culties or problems,
consult your dealer for help.
This air conditioner is designed to give you comfortable
room conditions. Use this only for its intended purpose as
described in these Operating Instructions.
WARNING
WARNING
4
This appliance is intended to be used
by expert or trained users in shops,
in light industry and on farms, or for
commercial use by lay persons.
This appliance is not intended for
use by persons (including children)
with reduced physical, sensory
or mental capabilities, or lack of
experience and knowledge, unless
they have been given supervision
or instruction concerning use of the
appliance by a person responsible
for their safety. Children should be
supervised to ensure that they do
not play with the appliance.
<for European market only>
This appliance can be used by
children aged from 8 years and
above and persons with reduced
physical, sensory or mental
capabilities or lack of experience and
knowledge if they have been given
supervision or instruction concerning
use of the appliance in a safe
way and understand the hazards
involved. Children shall not play with
the appliance. Cleaning and user
maintenance shall not be made by
children without supervision.
Keep the fi re alarm and the air outlet
at least 1.5m away from the unit.
Do not cool or heat the room too
much if babies or invalids are
present.
Do not turn the air conditioner on
and off from the power mains switch.
Use the ON/OFF operation button.
Do not stick anything into the
air outlet of the outdoor unit.
This is dangerous because the
fan is rotating at high speed.
Do not touch the air inlet or
the sharp aluminum fi ns of the
outdoor unit. You may get
injured.
Do not stick any object
into the FAN CASE. You
may be injured and the
unit may be damaged.
CAUTION Do not install at the following locations.
Humid, oily, frequent vibration, direct sunlight, nearby heat
source, frost (Cause of trouble)
Noise occurrence (Cause of malfunction)
Panel for cassette (ECONAVI type) is only for indoor use.
Do not scratch the surface of the sensor. (Cause of detected
error)
Do not press the sensor forcibly. (Cause of damage)
If any heating or cooling sources exists within the detection
area, the sensor may sometimes cannot detect correctly.
Do not wipe with benzine, thinner or disposal cloth. (Cause
of discoloration or deformation)
In case of heavy dirt, mix a tiny amount of neutral
detergent with water and soak it into a soft cloth, squeeze
well and gently wipe off the dirt. Then, wipe with a soft dry
cloth.
Do not install improper optional parts simultaneously with the
Panel for cassette (ECONAVI type). (Cause of malfunction)
See the catalogue and confi rm whether a combination use
is valid or invalid.
The movement of human body on the opposite side of the
mirror cannot be detected.
After actuation, it takes 2 to 5 minutes to verify the judgment
of presence and absence.
NOTICE
5
Precautions for Use
Installation
This optional of must be installed properly by qualifi ed
installation technicians in accordance with the Installation
Instructions provided with the unit.
Wiring
All wiring must conform to the local electrical codes.
(Consult your dealer or a qualifi ed electrician for details.)
Each unit must be properly grounded with a ground (or
earth) wire or through the supply wiring.
Wiring must be done by a qualifi ed electrician.
Operation Preparation
Turn the power mains on 5 hours before
the start of operation.
(For warm-up)
Leave the power mains ON for continuous use.
ON
NOTE
Pull off the power plug from a receptacle, or switch off the
breaker, or switch off the power disconnecting mean to isolate
the air conditioner from the main power supply when not in use
for a long time.
Information for Users on Collection and Disposal of
Old Equipment and Used Batteries
These symbols on the products, packaging,
and/or accompanying documents mean that
used electrical and electronic products and
batteries should not be mixed with general
household waste.
For proper treatment, recovery and recycling
of old products and used batteries, please
take them to applicable collection points, in
accordance with your national legislation and
the Directives 2002/96/EC and 2006/66/EC.
By disposing of these products and batteries
correctly, you will help to save valuable
resources and prevent any potential negative
effects on human health and the environment
which could otherwise arise from inappropriate
waste handling.
For more information about collection and
recycling of old products and batteries, please
contact your local municipality, your waste
disposal service or the point of sale where you
purchased the items.
Penalties may be applicable for incorrect
disposal of this waste, in accordance with
national legislation.
For business users in the European Union
If you wish to discard electrical and electronic
equipment, please contact your dealer or
supplier for further information.
[Information on Disposal in other Countries
outside the European Union]
These symbols are only valid in the European
Union. If you wish to discard these items,
please contact your local authorities or dealer
and ask for the correct method of disposal.
Pb
Note for the battery symbol (bottom two
symbol examples):
This symbol might be used in combination with
a chemical symbol. In this case it complies
with the requirement set by the Directive for
the chemical involved.
Tips for Energy Saving
Avoid
Do not block the air intake and outlet of the unit.
(If either is obstructed, the unit will not function
well, causing malfunction.)
During cooling operation, use sunshades, blinds or
curtains to prevent direct sunlight from entering the
room.
Do
Always keep the air fi lter clean.
(A clogged lter will impair the performance of the
unit.)
→ “Maintenance” (P.14)
To prevent conditioned air from escaping, keep
windows, doors and any other openings closed.
6
Names of Parts
Panel for Cassette
(ECONAVI type)
Flap
(4 locations)
Air intake grille
(air intake)
Air outlet
(4 locations)
Floor Temperature Sensor
Detects average temperature
of fl oor surface.
Human Detection Sensor
Detects human movement.
NOTE
Since the Human Detection Sensor enables to detect the heat transfer, it can not only detect human but it can
detect coexisting high-temperature objects.
(For example, movement of animals, swinging head freestanding type infrared heater, etc.)
The
Human Detection Sensor cannot detect human presence in some cases listed below.
In case of less human movement
In case of less exposure of the skin
In case of more than 30°C of room temperature
In case of greasy dirt, soot, dust, scratches adhered to a surface of Human Detection Sensor
Since the Floor Temperature Sensor measures the average temperature of the fl oor surface in the detection area,
there is a possibility that the sensor is infl uenced by a heat source existed in the range of the detection area. When
taking advantage of the function with the infl uence of the fl oor temperature (circulate function), pay attention to the
placement of a heat source.
7
Detection Area of Sensor (Criteria)
Criteria of human detection sensor area
Installation height of indoor unit 2.7 m : Approx.
ø
7 m
Installation height of indoor unit 4 m : Approx. ø8 m
Installation height of indoor unit 5 m : Approx. ø9 m
Approx.
ø
7 - 9 m
Detection area of
Human Detection
Sensor
1 m above fl oor visual range
Installation
height:
2.7 - 5 m
Detection area of Floor Temperature Sensor
NOTE
The further human is away from the Human Detection Sensor, the larger the movement of human body is required
to be detected.
A place where the blind angle of the Human Detection Sensor cannot detect human.
If there is a heat source or cooling unit in the detection area, the sensor cannot occasionally detect properly.
The Floor Temperature Senor detects within the sensor area of the Human Detection Sensor.
8
How to Operate Remote Controller
(Setting Method of Each Function)
NOTE
If the Operating Instructions supplied with the remote controller in use does not give descriptions of the ECONAVI
function, direct airflow / indirect airflow function, circulation function and external device interlock function, the in-use
remote controller is not available to these functions.
Refer to the Operating Instructions provided with the remote controller.
Sample of remote control display (CZ-RTC5B) when setting the ECONAVI function:
is displayed when setting the
ECONAVI function.
(In case of sensor error,
ECONAVI
is displayed in the
same position. See the Section “Troubleshooting” on page
15.)
Circulation Function
Displays when setting.
Direct Airfl ow / Indirect Airfl ow Function
Displays when setting.
Appears during circulation operation.


Produkt Specifikationer

Mærke: Panasonic
Kategori: Klimaanlæg
Model: CZ-KPU3AW

Har du brug for hjælp?

Hvis du har brug for hjælp til Panasonic CZ-KPU3AW stil et spørgsmål nedenfor, og andre brugere vil svare dig




Klimaanlæg Panasonic Manualer

Klimaanlæg Manualer

Nyeste Klimaanlæg Manualer